Cargando…

Noninvasive Quantification of In Vitro Osteoblastic Differentiation in 3D Engineered Tissue Constructs Using Spectral Ultrasound Imaging

Non-destructive monitoring of engineered tissues is needed for translation of these products from the lab to the clinic. In this study, non-invasive, high resolution spectral ultrasound imaging (SUSI) was used to monitor the differentiation of MC3T3 pre-osteoblasts seeded within collagen hydrogels....

Descripción completa

Detalles Bibliográficos
Autores principales: Gudur, Madhu Sudhan Reddy, Rao, Rameshwar R., Peterson, Alexis W., Caldwell, David J., Stegemann, Jan P., Deng, Cheri X.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3899074/
https://www.ncbi.nlm.nih.gov/pubmed/24465680
http://dx.doi.org/10.1371/journal.pone.0085749
_version_ 1782300517315117056
author Gudur, Madhu Sudhan Reddy
Rao, Rameshwar R.
Peterson, Alexis W.
Caldwell, David J.
Stegemann, Jan P.
Deng, Cheri X.
author_facet Gudur, Madhu Sudhan Reddy
Rao, Rameshwar R.
Peterson, Alexis W.
Caldwell, David J.
Stegemann, Jan P.
Deng, Cheri X.
author_sort Gudur, Madhu Sudhan Reddy
collection PubMed
description Non-destructive monitoring of engineered tissues is needed for translation of these products from the lab to the clinic. In this study, non-invasive, high resolution spectral ultrasound imaging (SUSI) was used to monitor the differentiation of MC3T3 pre-osteoblasts seeded within collagen hydrogels. SUSI was used to measure the diameter, concentration and acoustic attenuation of scatterers within such constructs cultured in either control or osteogenic medium over 21 days. Conventional biochemical assays were used on parallel samples to determine DNA content and calcium deposition. Construct volume and morphology were accurately imaged using ultrasound. Cell diameter was estimated to be approximately 12.5–15.5 µm using SUSI, which corresponded well to measurements of fluorescently stained cells. The total number of cells per construct assessed by quantitation of DNA content decreased from 5.6±2.4×10(4) at day 1 to 0.9±0.2×10(4) at day 21. SUSI estimation of the equivalent number of acoustic scatters showed a similar decreasing trend, except at day 21 in the osteogenic samples, which showed a marked increase in both scatterer number and acoustic impedance, suggestive of mineral deposition by the differentiating MC3T3 cells. Estimation of calcium content by SUSI was 41.7±11.4 µg/ml, which agreed well with the biochemical measurement of 38.7±16.7 µg/ml. Color coded maps of parameter values were overlaid on B-mode images to show spatiotemporal changes in cell diameter and calcium deposition. This study demonstrates the use of non-destructive ultrasound imaging to provide quantitative information on the number and differentiated state of cells embedded within 3D engineered constructs, and therefore presents a valuable tool for longitudinal monitoring of engineered tissue development.
format Online
Article
Text
id pubmed-3899074
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-38990742014-01-24 Noninvasive Quantification of In Vitro Osteoblastic Differentiation in 3D Engineered Tissue Constructs Using Spectral Ultrasound Imaging Gudur, Madhu Sudhan Reddy Rao, Rameshwar R. Peterson, Alexis W. Caldwell, David J. Stegemann, Jan P. Deng, Cheri X. PLoS One Research Article Non-destructive monitoring of engineered tissues is needed for translation of these products from the lab to the clinic. In this study, non-invasive, high resolution spectral ultrasound imaging (SUSI) was used to monitor the differentiation of MC3T3 pre-osteoblasts seeded within collagen hydrogels. SUSI was used to measure the diameter, concentration and acoustic attenuation of scatterers within such constructs cultured in either control or osteogenic medium over 21 days. Conventional biochemical assays were used on parallel samples to determine DNA content and calcium deposition. Construct volume and morphology were accurately imaged using ultrasound. Cell diameter was estimated to be approximately 12.5–15.5 µm using SUSI, which corresponded well to measurements of fluorescently stained cells. The total number of cells per construct assessed by quantitation of DNA content decreased from 5.6±2.4×10(4) at day 1 to 0.9±0.2×10(4) at day 21. SUSI estimation of the equivalent number of acoustic scatters showed a similar decreasing trend, except at day 21 in the osteogenic samples, which showed a marked increase in both scatterer number and acoustic impedance, suggestive of mineral deposition by the differentiating MC3T3 cells. Estimation of calcium content by SUSI was 41.7±11.4 µg/ml, which agreed well with the biochemical measurement of 38.7±16.7 µg/ml. Color coded maps of parameter values were overlaid on B-mode images to show spatiotemporal changes in cell diameter and calcium deposition. This study demonstrates the use of non-destructive ultrasound imaging to provide quantitative information on the number and differentiated state of cells embedded within 3D engineered constructs, and therefore presents a valuable tool for longitudinal monitoring of engineered tissue development. Public Library of Science 2014-01-22 /pmc/articles/PMC3899074/ /pubmed/24465680 http://dx.doi.org/10.1371/journal.pone.0085749 Text en © 2014 Gudur et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Gudur, Madhu Sudhan Reddy
Rao, Rameshwar R.
Peterson, Alexis W.
Caldwell, David J.
Stegemann, Jan P.
Deng, Cheri X.
Noninvasive Quantification of In Vitro Osteoblastic Differentiation in 3D Engineered Tissue Constructs Using Spectral Ultrasound Imaging
title Noninvasive Quantification of In Vitro Osteoblastic Differentiation in 3D Engineered Tissue Constructs Using Spectral Ultrasound Imaging
title_full Noninvasive Quantification of In Vitro Osteoblastic Differentiation in 3D Engineered Tissue Constructs Using Spectral Ultrasound Imaging
title_fullStr Noninvasive Quantification of In Vitro Osteoblastic Differentiation in 3D Engineered Tissue Constructs Using Spectral Ultrasound Imaging
title_full_unstemmed Noninvasive Quantification of In Vitro Osteoblastic Differentiation in 3D Engineered Tissue Constructs Using Spectral Ultrasound Imaging
title_short Noninvasive Quantification of In Vitro Osteoblastic Differentiation in 3D Engineered Tissue Constructs Using Spectral Ultrasound Imaging
title_sort noninvasive quantification of in vitro osteoblastic differentiation in 3d engineered tissue constructs using spectral ultrasound imaging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3899074/
https://www.ncbi.nlm.nih.gov/pubmed/24465680
http://dx.doi.org/10.1371/journal.pone.0085749
work_keys_str_mv AT gudurmadhusudhanreddy noninvasivequantificationofinvitroosteoblasticdifferentiationin3dengineeredtissueconstructsusingspectralultrasoundimaging
AT raorameshwarr noninvasivequantificationofinvitroosteoblasticdifferentiationin3dengineeredtissueconstructsusingspectralultrasoundimaging
AT petersonalexisw noninvasivequantificationofinvitroosteoblasticdifferentiationin3dengineeredtissueconstructsusingspectralultrasoundimaging
AT caldwelldavidj noninvasivequantificationofinvitroosteoblasticdifferentiationin3dengineeredtissueconstructsusingspectralultrasoundimaging
AT stegemannjanp noninvasivequantificationofinvitroosteoblasticdifferentiationin3dengineeredtissueconstructsusingspectralultrasoundimaging
AT dengcherix noninvasivequantificationofinvitroosteoblasticdifferentiationin3dengineeredtissueconstructsusingspectralultrasoundimaging