Cargando…
Reliability and Validity of a Point-of-Care Sural Nerve Conduction Device for Identification of Diabetic Neuropathy
BACKGROUND: Confirmation of diabetic sensorimotor polyneuropathy (DSP) relies on standard nerve conduction studies (NCS) performed in specialized clinics. We explored the utility of a point-of-care device (POCD) for DSP detection by nontechnical personnel and a validation of diagnostic thresholds wi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3899274/ https://www.ncbi.nlm.nih.gov/pubmed/24466129 http://dx.doi.org/10.1371/journal.pone.0086515 |
_version_ | 1782300548067753984 |
---|---|
author | Lee, Justin A. Halpern, Elise M. Lovblom, Leif E. Yeung, Emily Bril, Vera Perkins, Bruce A. |
author_facet | Lee, Justin A. Halpern, Elise M. Lovblom, Leif E. Yeung, Emily Bril, Vera Perkins, Bruce A. |
author_sort | Lee, Justin A. |
collection | PubMed |
description | BACKGROUND: Confirmation of diabetic sensorimotor polyneuropathy (DSP) relies on standard nerve conduction studies (NCS) performed in specialized clinics. We explored the utility of a point-of-care device (POCD) for DSP detection by nontechnical personnel and a validation of diagnostic thresholds with those observed in a normative database. RESEARCH DESIGN AND METHODS: 44 subjects with type 1 and type 2 diabetes underwent standard NCS (reference method). Two nontechnical examiners measured sural nerve amplitude potential (SNAP) and conduction velocity (SNCV) using the POCD. Reliability was determined by intraclass correlation coefficients (ICC [2], [1]). Validity was determined by Bland-Altman analysis and receiver operating characteristic curves. RESULTS: The 44 subjects (50% female) with mean age 56±18 years had mean SNAP and SNCV of 8.0±8.6 µV and 41.5±8.2 m/s using standard NCS and 8.0±8.2 µV and 49.9±11.1 m/s using the POCD. Intrarater reproducibility ICC values were 0.97 for SNAP and 0.94 for SNCV while interrater reproducibility values were 0.83 and 0.79, respectively. Mean bias of the POCD was −0.1±3.6 µV for SNAP and +8.4±6.4 m/s for SNCV. A SNAP of ≤6 µV had 88% sensitivity and 94% specificity for identifying age-and height-standardized reference NCS values, while a SNCV of ≤48 m/s had 94% specificity and 82% sensitivity. Abnormality in one or more of these thresholds was associated with 95% sensitivity and 71% specificity for identification of DSP according to electrophysiological criteria. CONCLUSIONS: The POCD demonstrated excellent reliability and acceptable accuracy. Threshold values for DSP identification validated those of published POCD normative values. We emphasize the presence of measurement bias – particularly for SNCV – that requires adjustment of threshold values to reflect those of standard NCS. |
format | Online Article Text |
id | pubmed-3899274 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-38992742014-01-24 Reliability and Validity of a Point-of-Care Sural Nerve Conduction Device for Identification of Diabetic Neuropathy Lee, Justin A. Halpern, Elise M. Lovblom, Leif E. Yeung, Emily Bril, Vera Perkins, Bruce A. PLoS One Research Article BACKGROUND: Confirmation of diabetic sensorimotor polyneuropathy (DSP) relies on standard nerve conduction studies (NCS) performed in specialized clinics. We explored the utility of a point-of-care device (POCD) for DSP detection by nontechnical personnel and a validation of diagnostic thresholds with those observed in a normative database. RESEARCH DESIGN AND METHODS: 44 subjects with type 1 and type 2 diabetes underwent standard NCS (reference method). Two nontechnical examiners measured sural nerve amplitude potential (SNAP) and conduction velocity (SNCV) using the POCD. Reliability was determined by intraclass correlation coefficients (ICC [2], [1]). Validity was determined by Bland-Altman analysis and receiver operating characteristic curves. RESULTS: The 44 subjects (50% female) with mean age 56±18 years had mean SNAP and SNCV of 8.0±8.6 µV and 41.5±8.2 m/s using standard NCS and 8.0±8.2 µV and 49.9±11.1 m/s using the POCD. Intrarater reproducibility ICC values were 0.97 for SNAP and 0.94 for SNCV while interrater reproducibility values were 0.83 and 0.79, respectively. Mean bias of the POCD was −0.1±3.6 µV for SNAP and +8.4±6.4 m/s for SNCV. A SNAP of ≤6 µV had 88% sensitivity and 94% specificity for identifying age-and height-standardized reference NCS values, while a SNCV of ≤48 m/s had 94% specificity and 82% sensitivity. Abnormality in one or more of these thresholds was associated with 95% sensitivity and 71% specificity for identification of DSP according to electrophysiological criteria. CONCLUSIONS: The POCD demonstrated excellent reliability and acceptable accuracy. Threshold values for DSP identification validated those of published POCD normative values. We emphasize the presence of measurement bias – particularly for SNCV – that requires adjustment of threshold values to reflect those of standard NCS. Public Library of Science 2014-01-22 /pmc/articles/PMC3899274/ /pubmed/24466129 http://dx.doi.org/10.1371/journal.pone.0086515 Text en © 2014 Lee et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Lee, Justin A. Halpern, Elise M. Lovblom, Leif E. Yeung, Emily Bril, Vera Perkins, Bruce A. Reliability and Validity of a Point-of-Care Sural Nerve Conduction Device for Identification of Diabetic Neuropathy |
title | Reliability and Validity of a Point-of-Care Sural Nerve Conduction Device for Identification of Diabetic Neuropathy |
title_full | Reliability and Validity of a Point-of-Care Sural Nerve Conduction Device for Identification of Diabetic Neuropathy |
title_fullStr | Reliability and Validity of a Point-of-Care Sural Nerve Conduction Device for Identification of Diabetic Neuropathy |
title_full_unstemmed | Reliability and Validity of a Point-of-Care Sural Nerve Conduction Device for Identification of Diabetic Neuropathy |
title_short | Reliability and Validity of a Point-of-Care Sural Nerve Conduction Device for Identification of Diabetic Neuropathy |
title_sort | reliability and validity of a point-of-care sural nerve conduction device for identification of diabetic neuropathy |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3899274/ https://www.ncbi.nlm.nih.gov/pubmed/24466129 http://dx.doi.org/10.1371/journal.pone.0086515 |
work_keys_str_mv | AT leejustina reliabilityandvalidityofapointofcaresuralnerveconductiondeviceforidentificationofdiabeticneuropathy AT halpernelisem reliabilityandvalidityofapointofcaresuralnerveconductiondeviceforidentificationofdiabeticneuropathy AT lovblomleife reliabilityandvalidityofapointofcaresuralnerveconductiondeviceforidentificationofdiabeticneuropathy AT yeungemily reliabilityandvalidityofapointofcaresuralnerveconductiondeviceforidentificationofdiabeticneuropathy AT brilvera reliabilityandvalidityofapointofcaresuralnerveconductiondeviceforidentificationofdiabeticneuropathy AT perkinsbrucea reliabilityandvalidityofapointofcaresuralnerveconductiondeviceforidentificationofdiabeticneuropathy |