New (125)I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design

PURPOSE: To determine the relative dose rate distribution around the new (125)I brachytherapy source IsoSeed I25.S17plus and report results in a form suitable for clinical use. Results for the new source are also compared to corresponding results for other commercially available (125)I sources of si...

Descripción completa

Detalles Bibliográficos
Autores principales: Pantelis, Evaggelos, Papagiannis, Panagiotis, Anagnostopoulos, Giorgos, Baltas, Dimos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3899641/
https://www.ncbi.nlm.nih.gov/pubmed/24474975
http://dx.doi.org/10.5114/jcb.2013.39631
_version_ 1782300608099778560
author Pantelis, Evaggelos
Papagiannis, Panagiotis
Anagnostopoulos, Giorgos
Baltas, Dimos
author_facet Pantelis, Evaggelos
Papagiannis, Panagiotis
Anagnostopoulos, Giorgos
Baltas, Dimos
author_sort Pantelis, Evaggelos
collection PubMed
description PURPOSE: To determine the relative dose rate distribution around the new (125)I brachytherapy source IsoSeed I25.S17plus and report results in a form suitable for clinical use. Results for the new source are also compared to corresponding results for other commercially available (125)I sources of similar design. MATERIAL AND METHODS: Monte Carlo simulations were performed using the MCNP5 v.1.6 general purpose code. The model of the new source was prepared from information provided by the manufacturer and verified by imaging a sample of ten non-radioactive sources. Corresponding simulations were also performed for the 6711 (125)I brachytherapy source, using updated geometric information presented recently in the literature. The uncertainty of the dose distribution around the new source, as well as the dosimetric quantities derived from it according to the Task Group 43 formalism, were determined from the standard error of the mean of simulations for a sample of fifty source models. These source models were prepared by randomly selecting values of geometric parameters from uniform distributions defined by manufacturer stated tolerances. RESULTS AND CONCLUSIONS: Results are presented in the form of the quantities defined in the update of the Task Group 43 report, as well as a relative dose rate table in Cartesian coordinates. The dose rate distribution of the new source is comparable to that of sources of similar design (IsoSeed I25.S17, Oncoseed 6711, SelectSeed 130.002, Advantage IAI-125A, I-Seed AgX100, Thinseed 9011). Noticeable differences were observed only for the IsoSeed I25.S06 and Best 2301 sources.
format Online
Article
Text
id pubmed-3899641
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-38996412014-01-28 New (125)I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design Pantelis, Evaggelos Papagiannis, Panagiotis Anagnostopoulos, Giorgos Baltas, Dimos J Contemp Brachytherapy Original Paper PURPOSE: To determine the relative dose rate distribution around the new (125)I brachytherapy source IsoSeed I25.S17plus and report results in a form suitable for clinical use. Results for the new source are also compared to corresponding results for other commercially available (125)I sources of similar design. MATERIAL AND METHODS: Monte Carlo simulations were performed using the MCNP5 v.1.6 general purpose code. The model of the new source was prepared from information provided by the manufacturer and verified by imaging a sample of ten non-radioactive sources. Corresponding simulations were also performed for the 6711 (125)I brachytherapy source, using updated geometric information presented recently in the literature. The uncertainty of the dose distribution around the new source, as well as the dosimetric quantities derived from it according to the Task Group 43 formalism, were determined from the standard error of the mean of simulations for a sample of fifty source models. These source models were prepared by randomly selecting values of geometric parameters from uniform distributions defined by manufacturer stated tolerances. RESULTS AND CONCLUSIONS: Results are presented in the form of the quantities defined in the update of the Task Group 43 report, as well as a relative dose rate table in Cartesian coordinates. The dose rate distribution of the new source is comparable to that of sources of similar design (IsoSeed I25.S17, Oncoseed 6711, SelectSeed 130.002, Advantage IAI-125A, I-Seed AgX100, Thinseed 9011). Noticeable differences were observed only for the IsoSeed I25.S06 and Best 2301 sources. Termedia Publishing House 2013-12-21 2013-12 /pmc/articles/PMC3899641/ /pubmed/24474975 http://dx.doi.org/10.5114/jcb.2013.39631 Text en Copyright © 2013 Termedia http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Paper
Pantelis, Evaggelos
Papagiannis, Panagiotis
Anagnostopoulos, Giorgos
Baltas, Dimos
New (125)I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design
title New (125)I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design
title_full New (125)I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design
title_fullStr New (125)I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design
title_full_unstemmed New (125)I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design
title_short New (125)I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design
title_sort new (125)i brachytherapy source isoseed i25.s17plus: monte carlo dosimetry simulation and comparison to sources of similar design
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3899641/
https://www.ncbi.nlm.nih.gov/pubmed/24474975
http://dx.doi.org/10.5114/jcb.2013.39631
work_keys_str_mv AT pantelisevaggelos new125ibrachytherapysourceisoseedi25s17plusmontecarlodosimetrysimulationandcomparisontosourcesofsimilardesign
AT papagiannispanagiotis new125ibrachytherapysourceisoseedi25s17plusmontecarlodosimetrysimulationandcomparisontosourcesofsimilardesign
AT anagnostopoulosgiorgos new125ibrachytherapysourceisoseedi25s17plusmontecarlodosimetrysimulationandcomparisontosourcesofsimilardesign
AT baltasdimos new125ibrachytherapysourceisoseedi25s17plusmontecarlodosimetrysimulationandcomparisontosourcesofsimilardesign