Cargando…

The effects of transport by pneumatic tube system on blood cell count, erythrocyte sedimentation and coagulation tests

INTRODUCTION: Today, the pneumatic tube transport system (PTS) is used frequently because of its advantages related to timing and speed. However, the impact of various types of PTS on blood components is unknown. The aim of this study was to examine the influence of PTS on the quality of routine blo...

Descripción completa

Detalles Bibliográficos
Autores principales: Koçak, Fatma Emel, Yöntem, Mustafa, Yücel, Özlem, Çilo, Mustafa, Genç, Özlem, Meral, Ayfer
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Croatian Society of Medical Biochemistry and Laboratory Medicine 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3900063/
https://www.ncbi.nlm.nih.gov/pubmed/23894866
http://dx.doi.org/10.11613/BM.2013.024
_version_ 1782300653173866496
author Koçak, Fatma Emel
Yöntem, Mustafa
Yücel, Özlem
Çilo, Mustafa
Genç, Özlem
Meral, Ayfer
author_facet Koçak, Fatma Emel
Yöntem, Mustafa
Yücel, Özlem
Çilo, Mustafa
Genç, Özlem
Meral, Ayfer
author_sort Koçak, Fatma Emel
collection PubMed
description INTRODUCTION: Today, the pneumatic tube transport system (PTS) is used frequently because of its advantages related to timing and speed. However, the impact of various types of PTS on blood components is unknown. The aim of this study was to examine the influence of PTS on the quality of routine blood cell counts, erythrocyte sedimentation, and certain blood coagulation tests. MATERIALS AND METHODS: Paired blood samples were obtained from each of 45 human volunteers and evaluated by blood cell count, erythrocyte sedimentation, and several coagulation tests, including prothrombin time (PT) and activated partial thromboplastin time (aPTT). Blood samples were divided into 2 groups: Samples from group 1 were transported to the laboratory via the PTS, and samples from group 2 were transported to the laboratory manually. Both groups were evaluated immediately by the tests listed above. RESULTS: The blood sample test results from groups 1 and 2 were evaluated and compared. No statistically significant differences were observed (P = 0.069–0.977). CONCLUSION: The PTS yielded no observable effects on blood cell counts, erythrocyte sedimentation, or PT and aPTT test results. We concluded that the PTS can be used to transport blood samples and yield reliable results for blood cell counts, erythrocyte sedimentation, and several coagulation tests.
format Online
Article
Text
id pubmed-3900063
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Croatian Society of Medical Biochemistry and Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-39000632014-01-23 The effects of transport by pneumatic tube system on blood cell count, erythrocyte sedimentation and coagulation tests Koçak, Fatma Emel Yöntem, Mustafa Yücel, Özlem Çilo, Mustafa Genç, Özlem Meral, Ayfer Biochem Med (Zagreb) Original Papers INTRODUCTION: Today, the pneumatic tube transport system (PTS) is used frequently because of its advantages related to timing and speed. However, the impact of various types of PTS on blood components is unknown. The aim of this study was to examine the influence of PTS on the quality of routine blood cell counts, erythrocyte sedimentation, and certain blood coagulation tests. MATERIALS AND METHODS: Paired blood samples were obtained from each of 45 human volunteers and evaluated by blood cell count, erythrocyte sedimentation, and several coagulation tests, including prothrombin time (PT) and activated partial thromboplastin time (aPTT). Blood samples were divided into 2 groups: Samples from group 1 were transported to the laboratory via the PTS, and samples from group 2 were transported to the laboratory manually. Both groups were evaluated immediately by the tests listed above. RESULTS: The blood sample test results from groups 1 and 2 were evaluated and compared. No statistically significant differences were observed (P = 0.069–0.977). CONCLUSION: The PTS yielded no observable effects on blood cell counts, erythrocyte sedimentation, or PT and aPTT test results. We concluded that the PTS can be used to transport blood samples and yield reliable results for blood cell counts, erythrocyte sedimentation, and several coagulation tests. Croatian Society of Medical Biochemistry and Laboratory Medicine 2013-06-15 /pmc/articles/PMC3900063/ /pubmed/23894866 http://dx.doi.org/10.11613/BM.2013.024 Text en ©Copyright by Croatian Society of Medical Biochemistry and Laboratory Medicine This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Papers
Koçak, Fatma Emel
Yöntem, Mustafa
Yücel, Özlem
Çilo, Mustafa
Genç, Özlem
Meral, Ayfer
The effects of transport by pneumatic tube system on blood cell count, erythrocyte sedimentation and coagulation tests
title The effects of transport by pneumatic tube system on blood cell count, erythrocyte sedimentation and coagulation tests
title_full The effects of transport by pneumatic tube system on blood cell count, erythrocyte sedimentation and coagulation tests
title_fullStr The effects of transport by pneumatic tube system on blood cell count, erythrocyte sedimentation and coagulation tests
title_full_unstemmed The effects of transport by pneumatic tube system on blood cell count, erythrocyte sedimentation and coagulation tests
title_short The effects of transport by pneumatic tube system on blood cell count, erythrocyte sedimentation and coagulation tests
title_sort effects of transport by pneumatic tube system on blood cell count, erythrocyte sedimentation and coagulation tests
topic Original Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3900063/
https://www.ncbi.nlm.nih.gov/pubmed/23894866
http://dx.doi.org/10.11613/BM.2013.024
work_keys_str_mv AT kocakfatmaemel theeffectsoftransportbypneumatictubesystemonbloodcellcounterythrocytesedimentationandcoagulationtests
AT yontemmustafa theeffectsoftransportbypneumatictubesystemonbloodcellcounterythrocytesedimentationandcoagulationtests
AT yucelozlem theeffectsoftransportbypneumatictubesystemonbloodcellcounterythrocytesedimentationandcoagulationtests
AT cilomustafa theeffectsoftransportbypneumatictubesystemonbloodcellcounterythrocytesedimentationandcoagulationtests
AT gencozlem theeffectsoftransportbypneumatictubesystemonbloodcellcounterythrocytesedimentationandcoagulationtests
AT meralayfer theeffectsoftransportbypneumatictubesystemonbloodcellcounterythrocytesedimentationandcoagulationtests
AT kocakfatmaemel effectsoftransportbypneumatictubesystemonbloodcellcounterythrocytesedimentationandcoagulationtests
AT yontemmustafa effectsoftransportbypneumatictubesystemonbloodcellcounterythrocytesedimentationandcoagulationtests
AT yucelozlem effectsoftransportbypneumatictubesystemonbloodcellcounterythrocytesedimentationandcoagulationtests
AT cilomustafa effectsoftransportbypneumatictubesystemonbloodcellcounterythrocytesedimentationandcoagulationtests
AT gencozlem effectsoftransportbypneumatictubesystemonbloodcellcounterythrocytesedimentationandcoagulationtests
AT meralayfer effectsoftransportbypneumatictubesystemonbloodcellcounterythrocytesedimentationandcoagulationtests