Avoidance to wipe alcohol before venipuncture is not a source of spurious hemolysis
BACKGROUND: It is still uncertain whether or not avoidance to let disinfectant alcohol dry at the site of venipuncture is a source of spurious hemolysis when drawing venous blood. METHODS: In a consecutive series of 52 outpatients referred for routine laboratory testing, venous blood was drawn by di...
Autores principales: | Salvagno, Gian Luca, Danese, Elisa, Lima-Oliveira, Gabriel, Guidi, Gian Cesare, Lippi, Giuseppe |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Croatian Society of Medical Biochemistry and Laboratory Medicine
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3900069/ https://www.ncbi.nlm.nih.gov/pubmed/23894865 http://dx.doi.org/10.11613/BM.2013.023 |
Ejemplares similares
-
Patient posture for blood collection by venipuncture: recall for standardization after 28 years
por: Lima-Oliveira, Gabriel, et al.
Publicado: (2017) -
Impact of the phlebotomy training based on CLSI/NCCLS H03-A6 - procedures for the collection of diagnostic blood specimens by venipuncture.
por: Lima-Oliveira, Gabriel, et al.
Publicado: (2012) -
The alcohol used for cleansing the venipuncture site does not jeopardize blood and plasma alcohol measurement with head-space gas chromatography and an enzymatic assay
por: Lippi, Giuseppe, et al.
Publicado: (2017) -
Contamination of lithium heparin blood by K2-ethylenediaminetetraacetic acid (EDTA): an experimental evaluation
por: Lima-Oliveira, Gabriel, et al.
Publicado: (2014) -
Variation of Red Blood Cell Distribution Width and Mean Platelet Volume after Moderate Endurance Exercise
por: Lippi, Giuseppe, et al.
Publicado: (2014)