Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference

PURPOSE: To evaluate the distance between the endothelial surface of the cornea to the anterior edge of an Artiflex® phakic intraocular lens (IOL) implant to improve the safety profile of this implant. METHODS: This is a retrospective clinical case series of 45 patients who had Artiflex phakic IOL i...

Descripción completa

Detalles Bibliográficos
Autores principales: Ferreira, Tiago Bravo, Portelinha, Joana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3900334/
https://www.ncbi.nlm.nih.gov/pubmed/24465125
http://dx.doi.org/10.2147/OPTH.S56484
_version_ 1782300672600834048
author Ferreira, Tiago Bravo
Portelinha, Joana
author_facet Ferreira, Tiago Bravo
Portelinha, Joana
author_sort Ferreira, Tiago Bravo
collection PubMed
description PURPOSE: To evaluate the distance between the endothelial surface of the cornea to the anterior edge of an Artiflex® phakic intraocular lens (IOL) implant to improve the safety profile of this implant. METHODS: This is a retrospective clinical case series of 45 patients who had Artiflex phakic IOL implantation (Artiflex p-IOL) with a follow-up period of 3 years. A Pentacam HR imaging system was used to measure the distance from various points of the anterior edge of the Artiflex IOL to the endothelial surface of the cornea, which we called endothelial–IOL (E–IOL) distance, in 45 eyes. The E–IOL distances were assessed at 1, 3, 6, 12, 24, and 36 months. Corresponding correlations of central endothelial distance to temporal and nasal edges and center of the IOL anterior surface were tabulated. RESULTS: Mean follow-up was 21.39±11.28 months. A statistically significant reduction of the E–IOL distance was observed over the follow-up period (P<0.05), with the mean annual reduction being 24.70 μm. A strong positive correlation between the E–IOL distance of the edges of the IOL and the central distance was observed (correlation coefficients nasal/central: month 1, 0.905; month 36, 0.806; temporal/central: month 1, 0.906; month 36, 0.806; P<0.001). Moderate negative correlations were found between the spherical equivalent power of the implanted IOL and the E–IOL distance (correlation coefficients −0.271 to −0.412, P>0.05). For an E–IOL distance of the IOL edge >1500 μm, the distance from the endothelium to the central point of the p-IOL optic should be a minimum of 1,700 μm to improve the safety profile for Artiflex p-IOL implantation and reduce the potential complication of accelerated endothelial cell loss. CONCLUSION: After Artiflex IOL implantation, the mean annual reduction of the E–IOL distance was 25 μm. A negative correlation existed between the spherical equivalent power of the implanted IOL and the postoperative E–IOL distance. The minimum E–IOL distance from the center of the IOL to minimize the risk of endothelial cell loss was 1.7 mm. This distance, as is the 1.5 mm initially proposed by Baikoff, is a postoperative value. We cannot make that assumption for the preoperative evaluation, as the morphometry of the anterior chamber changes with the implant.
format Online
Article
Text
id pubmed-3900334
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-39003342014-01-24 Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference Ferreira, Tiago Bravo Portelinha, Joana Clin Ophthalmol Original Research PURPOSE: To evaluate the distance between the endothelial surface of the cornea to the anterior edge of an Artiflex® phakic intraocular lens (IOL) implant to improve the safety profile of this implant. METHODS: This is a retrospective clinical case series of 45 patients who had Artiflex phakic IOL implantation (Artiflex p-IOL) with a follow-up period of 3 years. A Pentacam HR imaging system was used to measure the distance from various points of the anterior edge of the Artiflex IOL to the endothelial surface of the cornea, which we called endothelial–IOL (E–IOL) distance, in 45 eyes. The E–IOL distances were assessed at 1, 3, 6, 12, 24, and 36 months. Corresponding correlations of central endothelial distance to temporal and nasal edges and center of the IOL anterior surface were tabulated. RESULTS: Mean follow-up was 21.39±11.28 months. A statistically significant reduction of the E–IOL distance was observed over the follow-up period (P<0.05), with the mean annual reduction being 24.70 μm. A strong positive correlation between the E–IOL distance of the edges of the IOL and the central distance was observed (correlation coefficients nasal/central: month 1, 0.905; month 36, 0.806; temporal/central: month 1, 0.906; month 36, 0.806; P<0.001). Moderate negative correlations were found between the spherical equivalent power of the implanted IOL and the E–IOL distance (correlation coefficients −0.271 to −0.412, P>0.05). For an E–IOL distance of the IOL edge >1500 μm, the distance from the endothelium to the central point of the p-IOL optic should be a minimum of 1,700 μm to improve the safety profile for Artiflex p-IOL implantation and reduce the potential complication of accelerated endothelial cell loss. CONCLUSION: After Artiflex IOL implantation, the mean annual reduction of the E–IOL distance was 25 μm. A negative correlation existed between the spherical equivalent power of the implanted IOL and the postoperative E–IOL distance. The minimum E–IOL distance from the center of the IOL to minimize the risk of endothelial cell loss was 1.7 mm. This distance, as is the 1.5 mm initially proposed by Baikoff, is a postoperative value. We cannot make that assumption for the preoperative evaluation, as the morphometry of the anterior chamber changes with the implant. Dove Medical Press 2014 2014-01-17 /pmc/articles/PMC3900334/ /pubmed/24465125 http://dx.doi.org/10.2147/OPTH.S56484 Text en © 2014 Ferreira and Portelinha. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Ferreira, Tiago Bravo
Portelinha, Joana
Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference
title Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference
title_full Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference
title_fullStr Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference
title_full_unstemmed Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference
title_short Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference
title_sort endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3900334/
https://www.ncbi.nlm.nih.gov/pubmed/24465125
http://dx.doi.org/10.2147/OPTH.S56484
work_keys_str_mv AT ferreiratiagobravo endothelialdistanceafterphakicirisfixatedintraocularlensimplantationanewsafetyreference
AT portelinhajoana endothelialdistanceafterphakicirisfixatedintraocularlensimplantationanewsafetyreference