Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference
PURPOSE: To evaluate the distance between the endothelial surface of the cornea to the anterior edge of an Artiflex® phakic intraocular lens (IOL) implant to improve the safety profile of this implant. METHODS: This is a retrospective clinical case series of 45 patients who had Artiflex phakic IOL i...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3900334/ https://www.ncbi.nlm.nih.gov/pubmed/24465125 http://dx.doi.org/10.2147/OPTH.S56484 |
_version_ | 1782300672600834048 |
---|---|
author | Ferreira, Tiago Bravo Portelinha, Joana |
author_facet | Ferreira, Tiago Bravo Portelinha, Joana |
author_sort | Ferreira, Tiago Bravo |
collection | PubMed |
description | PURPOSE: To evaluate the distance between the endothelial surface of the cornea to the anterior edge of an Artiflex® phakic intraocular lens (IOL) implant to improve the safety profile of this implant. METHODS: This is a retrospective clinical case series of 45 patients who had Artiflex phakic IOL implantation (Artiflex p-IOL) with a follow-up period of 3 years. A Pentacam HR imaging system was used to measure the distance from various points of the anterior edge of the Artiflex IOL to the endothelial surface of the cornea, which we called endothelial–IOL (E–IOL) distance, in 45 eyes. The E–IOL distances were assessed at 1, 3, 6, 12, 24, and 36 months. Corresponding correlations of central endothelial distance to temporal and nasal edges and center of the IOL anterior surface were tabulated. RESULTS: Mean follow-up was 21.39±11.28 months. A statistically significant reduction of the E–IOL distance was observed over the follow-up period (P<0.05), with the mean annual reduction being 24.70 μm. A strong positive correlation between the E–IOL distance of the edges of the IOL and the central distance was observed (correlation coefficients nasal/central: month 1, 0.905; month 36, 0.806; temporal/central: month 1, 0.906; month 36, 0.806; P<0.001). Moderate negative correlations were found between the spherical equivalent power of the implanted IOL and the E–IOL distance (correlation coefficients −0.271 to −0.412, P>0.05). For an E–IOL distance of the IOL edge >1500 μm, the distance from the endothelium to the central point of the p-IOL optic should be a minimum of 1,700 μm to improve the safety profile for Artiflex p-IOL implantation and reduce the potential complication of accelerated endothelial cell loss. CONCLUSION: After Artiflex IOL implantation, the mean annual reduction of the E–IOL distance was 25 μm. A negative correlation existed between the spherical equivalent power of the implanted IOL and the postoperative E–IOL distance. The minimum E–IOL distance from the center of the IOL to minimize the risk of endothelial cell loss was 1.7 mm. This distance, as is the 1.5 mm initially proposed by Baikoff, is a postoperative value. We cannot make that assumption for the preoperative evaluation, as the morphometry of the anterior chamber changes with the implant. |
format | Online Article Text |
id | pubmed-3900334 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-39003342014-01-24 Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference Ferreira, Tiago Bravo Portelinha, Joana Clin Ophthalmol Original Research PURPOSE: To evaluate the distance between the endothelial surface of the cornea to the anterior edge of an Artiflex® phakic intraocular lens (IOL) implant to improve the safety profile of this implant. METHODS: This is a retrospective clinical case series of 45 patients who had Artiflex phakic IOL implantation (Artiflex p-IOL) with a follow-up period of 3 years. A Pentacam HR imaging system was used to measure the distance from various points of the anterior edge of the Artiflex IOL to the endothelial surface of the cornea, which we called endothelial–IOL (E–IOL) distance, in 45 eyes. The E–IOL distances were assessed at 1, 3, 6, 12, 24, and 36 months. Corresponding correlations of central endothelial distance to temporal and nasal edges and center of the IOL anterior surface were tabulated. RESULTS: Mean follow-up was 21.39±11.28 months. A statistically significant reduction of the E–IOL distance was observed over the follow-up period (P<0.05), with the mean annual reduction being 24.70 μm. A strong positive correlation between the E–IOL distance of the edges of the IOL and the central distance was observed (correlation coefficients nasal/central: month 1, 0.905; month 36, 0.806; temporal/central: month 1, 0.906; month 36, 0.806; P<0.001). Moderate negative correlations were found between the spherical equivalent power of the implanted IOL and the E–IOL distance (correlation coefficients −0.271 to −0.412, P>0.05). For an E–IOL distance of the IOL edge >1500 μm, the distance from the endothelium to the central point of the p-IOL optic should be a minimum of 1,700 μm to improve the safety profile for Artiflex p-IOL implantation and reduce the potential complication of accelerated endothelial cell loss. CONCLUSION: After Artiflex IOL implantation, the mean annual reduction of the E–IOL distance was 25 μm. A negative correlation existed between the spherical equivalent power of the implanted IOL and the postoperative E–IOL distance. The minimum E–IOL distance from the center of the IOL to minimize the risk of endothelial cell loss was 1.7 mm. This distance, as is the 1.5 mm initially proposed by Baikoff, is a postoperative value. We cannot make that assumption for the preoperative evaluation, as the morphometry of the anterior chamber changes with the implant. Dove Medical Press 2014 2014-01-17 /pmc/articles/PMC3900334/ /pubmed/24465125 http://dx.doi.org/10.2147/OPTH.S56484 Text en © 2014 Ferreira and Portelinha. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Ferreira, Tiago Bravo Portelinha, Joana Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference |
title | Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference |
title_full | Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference |
title_fullStr | Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference |
title_full_unstemmed | Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference |
title_short | Endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference |
title_sort | endothelial distance after phakic iris-fixated intraocular lens implantation: a new safety reference |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3900334/ https://www.ncbi.nlm.nih.gov/pubmed/24465125 http://dx.doi.org/10.2147/OPTH.S56484 |
work_keys_str_mv | AT ferreiratiagobravo endothelialdistanceafterphakicirisfixatedintraocularlensimplantationanewsafetyreference AT portelinhajoana endothelialdistanceafterphakicirisfixatedintraocularlensimplantationanewsafetyreference |