Cargando…

Comparison of ELISpot and FluoroSpot in the Analysis of Swine Flu-Specific IgG and IgA Secretion by in Vivo Activated Human B Cells

We have evaluated a novel B-cell FluoroSpot assay for the analysis of antibody responses in healthy individuals vaccinated intramuscularly with Influenza A (H1N1) antigen (Pandemrix(®), GlaxoSmithKline). Using the FluoroSpot assay and an ELISpot assay run in parallel for comparison, we measured the...

Descripción completa

Detalles Bibliográficos
Autores principales: Kesa, Gun, Larsson, Per H., Ahlborg, Niklas, Axelsson, Bernt
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3901096/
https://www.ncbi.nlm.nih.gov/pubmed/24710411
http://dx.doi.org/10.3390/cells1020027
_version_ 1782300797929783296
author Kesa, Gun
Larsson, Per H.
Ahlborg, Niklas
Axelsson, Bernt
author_facet Kesa, Gun
Larsson, Per H.
Ahlborg, Niklas
Axelsson, Bernt
author_sort Kesa, Gun
collection PubMed
description We have evaluated a novel B-cell FluoroSpot assay for the analysis of antibody responses in healthy individuals vaccinated intramuscularly with Influenza A (H1N1) antigen (Pandemrix(®), GlaxoSmithKline). Using the FluoroSpot assay and an ELISpot assay run in parallel for comparison, we measured the frequency of cells secreting antigen-specific as well as total IgG or IgA antibodies seven days post vaccination. The assays were based on high affinity monoclonal antibodies for capture and detection of human IgG and IgA. Whereas conventional ELISpot analyzes IgG- and IgA-secreting B cells separately, fluorescent detection enabled simultaneous enumeration of B cells secreting IgG or IgA in the same well. The FluoroSpot protocol was also simpler as the assay could be performed without the need for an amplifying detection step. While having all the advantages of a conventional ELISpot assay, including high sensitivity, robustness and ease of performance, the FluoroSpot assay adds further value in reducing costs, time and material.
format Online
Article
Text
id pubmed-3901096
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-39010962014-04-07 Comparison of ELISpot and FluoroSpot in the Analysis of Swine Flu-Specific IgG and IgA Secretion by in Vivo Activated Human B Cells Kesa, Gun Larsson, Per H. Ahlborg, Niklas Axelsson, Bernt Cells Article We have evaluated a novel B-cell FluoroSpot assay for the analysis of antibody responses in healthy individuals vaccinated intramuscularly with Influenza A (H1N1) antigen (Pandemrix(®), GlaxoSmithKline). Using the FluoroSpot assay and an ELISpot assay run in parallel for comparison, we measured the frequency of cells secreting antigen-specific as well as total IgG or IgA antibodies seven days post vaccination. The assays were based on high affinity monoclonal antibodies for capture and detection of human IgG and IgA. Whereas conventional ELISpot analyzes IgG- and IgA-secreting B cells separately, fluorescent detection enabled simultaneous enumeration of B cells secreting IgG or IgA in the same well. The FluoroSpot protocol was also simpler as the assay could be performed without the need for an amplifying detection step. While having all the advantages of a conventional ELISpot assay, including high sensitivity, robustness and ease of performance, the FluoroSpot assay adds further value in reducing costs, time and material. MDPI 2012-04-20 /pmc/articles/PMC3901096/ /pubmed/24710411 http://dx.doi.org/10.3390/cells1020027 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland. http://creativecommons.org/licenses/by/3.0/ This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Kesa, Gun
Larsson, Per H.
Ahlborg, Niklas
Axelsson, Bernt
Comparison of ELISpot and FluoroSpot in the Analysis of Swine Flu-Specific IgG and IgA Secretion by in Vivo Activated Human B Cells
title Comparison of ELISpot and FluoroSpot in the Analysis of Swine Flu-Specific IgG and IgA Secretion by in Vivo Activated Human B Cells
title_full Comparison of ELISpot and FluoroSpot in the Analysis of Swine Flu-Specific IgG and IgA Secretion by in Vivo Activated Human B Cells
title_fullStr Comparison of ELISpot and FluoroSpot in the Analysis of Swine Flu-Specific IgG and IgA Secretion by in Vivo Activated Human B Cells
title_full_unstemmed Comparison of ELISpot and FluoroSpot in the Analysis of Swine Flu-Specific IgG and IgA Secretion by in Vivo Activated Human B Cells
title_short Comparison of ELISpot and FluoroSpot in the Analysis of Swine Flu-Specific IgG and IgA Secretion by in Vivo Activated Human B Cells
title_sort comparison of elispot and fluorospot in the analysis of swine flu-specific igg and iga secretion by in vivo activated human b cells
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3901096/
https://www.ncbi.nlm.nih.gov/pubmed/24710411
http://dx.doi.org/10.3390/cells1020027
work_keys_str_mv AT kesagun comparisonofelispotandfluorospotintheanalysisofswinefluspecificiggandigasecretionbyinvivoactivatedhumanbcells
AT larssonperh comparisonofelispotandfluorospotintheanalysisofswinefluspecificiggandigasecretionbyinvivoactivatedhumanbcells
AT ahlborgniklas comparisonofelispotandfluorospotintheanalysisofswinefluspecificiggandigasecretionbyinvivoactivatedhumanbcells
AT axelssonbernt comparisonofelispotandfluorospotintheanalysisofswinefluspecificiggandigasecretionbyinvivoactivatedhumanbcells