Cargando…
Comparison of ELISpot and FluoroSpot in the Analysis of Swine Flu-Specific IgG and IgA Secretion by in Vivo Activated Human B Cells
We have evaluated a novel B-cell FluoroSpot assay for the analysis of antibody responses in healthy individuals vaccinated intramuscularly with Influenza A (H1N1) antigen (Pandemrix(®), GlaxoSmithKline). Using the FluoroSpot assay and an ELISpot assay run in parallel for comparison, we measured the...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3901096/ https://www.ncbi.nlm.nih.gov/pubmed/24710411 http://dx.doi.org/10.3390/cells1020027 |
_version_ | 1782300797929783296 |
---|---|
author | Kesa, Gun Larsson, Per H. Ahlborg, Niklas Axelsson, Bernt |
author_facet | Kesa, Gun Larsson, Per H. Ahlborg, Niklas Axelsson, Bernt |
author_sort | Kesa, Gun |
collection | PubMed |
description | We have evaluated a novel B-cell FluoroSpot assay for the analysis of antibody responses in healthy individuals vaccinated intramuscularly with Influenza A (H1N1) antigen (Pandemrix(®), GlaxoSmithKline). Using the FluoroSpot assay and an ELISpot assay run in parallel for comparison, we measured the frequency of cells secreting antigen-specific as well as total IgG or IgA antibodies seven days post vaccination. The assays were based on high affinity monoclonal antibodies for capture and detection of human IgG and IgA. Whereas conventional ELISpot analyzes IgG- and IgA-secreting B cells separately, fluorescent detection enabled simultaneous enumeration of B cells secreting IgG or IgA in the same well. The FluoroSpot protocol was also simpler as the assay could be performed without the need for an amplifying detection step. While having all the advantages of a conventional ELISpot assay, including high sensitivity, robustness and ease of performance, the FluoroSpot assay adds further value in reducing costs, time and material. |
format | Online Article Text |
id | pubmed-3901096 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-39010962014-04-07 Comparison of ELISpot and FluoroSpot in the Analysis of Swine Flu-Specific IgG and IgA Secretion by in Vivo Activated Human B Cells Kesa, Gun Larsson, Per H. Ahlborg, Niklas Axelsson, Bernt Cells Article We have evaluated a novel B-cell FluoroSpot assay for the analysis of antibody responses in healthy individuals vaccinated intramuscularly with Influenza A (H1N1) antigen (Pandemrix(®), GlaxoSmithKline). Using the FluoroSpot assay and an ELISpot assay run in parallel for comparison, we measured the frequency of cells secreting antigen-specific as well as total IgG or IgA antibodies seven days post vaccination. The assays were based on high affinity monoclonal antibodies for capture and detection of human IgG and IgA. Whereas conventional ELISpot analyzes IgG- and IgA-secreting B cells separately, fluorescent detection enabled simultaneous enumeration of B cells secreting IgG or IgA in the same well. The FluoroSpot protocol was also simpler as the assay could be performed without the need for an amplifying detection step. While having all the advantages of a conventional ELISpot assay, including high sensitivity, robustness and ease of performance, the FluoroSpot assay adds further value in reducing costs, time and material. MDPI 2012-04-20 /pmc/articles/PMC3901096/ /pubmed/24710411 http://dx.doi.org/10.3390/cells1020027 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland. http://creativecommons.org/licenses/by/3.0/ This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Kesa, Gun Larsson, Per H. Ahlborg, Niklas Axelsson, Bernt Comparison of ELISpot and FluoroSpot in the Analysis of Swine Flu-Specific IgG and IgA Secretion by in Vivo Activated Human B Cells |
title | Comparison of ELISpot and FluoroSpot in the Analysis of Swine Flu-Specific IgG and IgA Secretion by in Vivo Activated Human B Cells |
title_full | Comparison of ELISpot and FluoroSpot in the Analysis of Swine Flu-Specific IgG and IgA Secretion by in Vivo Activated Human B Cells |
title_fullStr | Comparison of ELISpot and FluoroSpot in the Analysis of Swine Flu-Specific IgG and IgA Secretion by in Vivo Activated Human B Cells |
title_full_unstemmed | Comparison of ELISpot and FluoroSpot in the Analysis of Swine Flu-Specific IgG and IgA Secretion by in Vivo Activated Human B Cells |
title_short | Comparison of ELISpot and FluoroSpot in the Analysis of Swine Flu-Specific IgG and IgA Secretion by in Vivo Activated Human B Cells |
title_sort | comparison of elispot and fluorospot in the analysis of swine flu-specific igg and iga secretion by in vivo activated human b cells |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3901096/ https://www.ncbi.nlm.nih.gov/pubmed/24710411 http://dx.doi.org/10.3390/cells1020027 |
work_keys_str_mv | AT kesagun comparisonofelispotandfluorospotintheanalysisofswinefluspecificiggandigasecretionbyinvivoactivatedhumanbcells AT larssonperh comparisonofelispotandfluorospotintheanalysisofswinefluspecificiggandigasecretionbyinvivoactivatedhumanbcells AT ahlborgniklas comparisonofelispotandfluorospotintheanalysisofswinefluspecificiggandigasecretionbyinvivoactivatedhumanbcells AT axelssonbernt comparisonofelispotandfluorospotintheanalysisofswinefluspecificiggandigasecretionbyinvivoactivatedhumanbcells |