Rapid and simple detection of methicillin-resistance staphylococcus aureus by orfX loop-mediated isothermal amplification assay
BACKGROUND: Methicillin-resistant Staphylococcus aureus (MRSA) has become one of the most prevalent pathogens responsible for nosocomial infections throughout the world. As clinical MRSA diagnosis is concerned, current diagnostic methodologies are restricted by significant drawbacks and novel method...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3902190/ https://www.ncbi.nlm.nih.gov/pubmed/24456841 http://dx.doi.org/10.1186/1472-6750-14-8 |
_version_ | 1782300956304605184 |
---|---|
author | Su, Jianyu Liu, Xiaochen Cui, Hemiao Li, Yanyan Chen, Dingqiang Li, Yanmei Yu, Guangchao |
author_facet | Su, Jianyu Liu, Xiaochen Cui, Hemiao Li, Yanyan Chen, Dingqiang Li, Yanmei Yu, Guangchao |
author_sort | Su, Jianyu |
collection | PubMed |
description | BACKGROUND: Methicillin-resistant Staphylococcus aureus (MRSA) has become one of the most prevalent pathogens responsible for nosocomial infections throughout the world. As clinical MRSA diagnosis is concerned, current diagnostic methodologies are restricted by significant drawbacks and novel methods are required for MRSA detection. This study aimed at developing a simple loop-mediated isothermal amplification (LAMP) assay targeting on orfX for the rapid detection of methicillin-resistance Staphylococcus aureus (MRSA). RESULTS: The protocol was designed by targeting orfX, a highly conserved open reading frame in S. aureus. One hundred and sixteen reference strains, including 52 Gram-positive and 64 Gram-negative isolates, were included for evaluation and optimization of the orfX-LAMP assay. This assay had been further performed on 667 Staphylococcus (566 MRSA, 25 MSSA, 53 MRCNS and 23 MSCNS) strains and were comparatively validated by PCR assay using primers F3 and B3, with rapid template DNA processing, simple equipments (water bath) and direct result determination (both naked eye and under UV light) applied. The indispensability of each primer had been confirmed, and the optimal amplification was obtained under 65°C for 45 min. The 25 μl reactant was found to be the most cost-efficient volume, and the detection limit was determined to be 10 DNA copies and 10 CFU/reaction. High specificity was observed when orfX-LAMP assay was subjected to 116 reference strains. For application, 557 (98.4%, 557/566) and 519 (91.7%, 519/566) tested strains had been detected positive by LAMP and PCR assays. The detection rate, positive predictive value (PPV) and negative predictive value (NPV) of orfX-LAMP were 98.4%, 100% and 92.7% respectively. CONCLUSIONS: The established orfX-LAMP assay had been demonstrated to be a valid and rapid detection method on MRSA. |
format | Online Article Text |
id | pubmed-3902190 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-39021902014-01-28 Rapid and simple detection of methicillin-resistance staphylococcus aureus by orfX loop-mediated isothermal amplification assay Su, Jianyu Liu, Xiaochen Cui, Hemiao Li, Yanyan Chen, Dingqiang Li, Yanmei Yu, Guangchao BMC Biotechnol Methodology Article BACKGROUND: Methicillin-resistant Staphylococcus aureus (MRSA) has become one of the most prevalent pathogens responsible for nosocomial infections throughout the world. As clinical MRSA diagnosis is concerned, current diagnostic methodologies are restricted by significant drawbacks and novel methods are required for MRSA detection. This study aimed at developing a simple loop-mediated isothermal amplification (LAMP) assay targeting on orfX for the rapid detection of methicillin-resistance Staphylococcus aureus (MRSA). RESULTS: The protocol was designed by targeting orfX, a highly conserved open reading frame in S. aureus. One hundred and sixteen reference strains, including 52 Gram-positive and 64 Gram-negative isolates, were included for evaluation and optimization of the orfX-LAMP assay. This assay had been further performed on 667 Staphylococcus (566 MRSA, 25 MSSA, 53 MRCNS and 23 MSCNS) strains and were comparatively validated by PCR assay using primers F3 and B3, with rapid template DNA processing, simple equipments (water bath) and direct result determination (both naked eye and under UV light) applied. The indispensability of each primer had been confirmed, and the optimal amplification was obtained under 65°C for 45 min. The 25 μl reactant was found to be the most cost-efficient volume, and the detection limit was determined to be 10 DNA copies and 10 CFU/reaction. High specificity was observed when orfX-LAMP assay was subjected to 116 reference strains. For application, 557 (98.4%, 557/566) and 519 (91.7%, 519/566) tested strains had been detected positive by LAMP and PCR assays. The detection rate, positive predictive value (PPV) and negative predictive value (NPV) of orfX-LAMP were 98.4%, 100% and 92.7% respectively. CONCLUSIONS: The established orfX-LAMP assay had been demonstrated to be a valid and rapid detection method on MRSA. BioMed Central 2014-01-24 /pmc/articles/PMC3902190/ /pubmed/24456841 http://dx.doi.org/10.1186/1472-6750-14-8 Text en Copyright © 2014 Su et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Methodology Article Su, Jianyu Liu, Xiaochen Cui, Hemiao Li, Yanyan Chen, Dingqiang Li, Yanmei Yu, Guangchao Rapid and simple detection of methicillin-resistance staphylococcus aureus by orfX loop-mediated isothermal amplification assay |
title | Rapid and simple detection of methicillin-resistance staphylococcus aureus by orfX loop-mediated isothermal amplification assay |
title_full | Rapid and simple detection of methicillin-resistance staphylococcus aureus by orfX loop-mediated isothermal amplification assay |
title_fullStr | Rapid and simple detection of methicillin-resistance staphylococcus aureus by orfX loop-mediated isothermal amplification assay |
title_full_unstemmed | Rapid and simple detection of methicillin-resistance staphylococcus aureus by orfX loop-mediated isothermal amplification assay |
title_short | Rapid and simple detection of methicillin-resistance staphylococcus aureus by orfX loop-mediated isothermal amplification assay |
title_sort | rapid and simple detection of methicillin-resistance staphylococcus aureus by orfx loop-mediated isothermal amplification assay |
topic | Methodology Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3902190/ https://www.ncbi.nlm.nih.gov/pubmed/24456841 http://dx.doi.org/10.1186/1472-6750-14-8 |
work_keys_str_mv | AT sujianyu rapidandsimpledetectionofmethicillinresistancestaphylococcusaureusbyorfxloopmediatedisothermalamplificationassay AT liuxiaochen rapidandsimpledetectionofmethicillinresistancestaphylococcusaureusbyorfxloopmediatedisothermalamplificationassay AT cuihemiao rapidandsimpledetectionofmethicillinresistancestaphylococcusaureusbyorfxloopmediatedisothermalamplificationassay AT liyanyan rapidandsimpledetectionofmethicillinresistancestaphylococcusaureusbyorfxloopmediatedisothermalamplificationassay AT chendingqiang rapidandsimpledetectionofmethicillinresistancestaphylococcusaureusbyorfxloopmediatedisothermalamplificationassay AT liyanmei rapidandsimpledetectionofmethicillinresistancestaphylococcusaureusbyorfxloopmediatedisothermalamplificationassay AT yuguangchao rapidandsimpledetectionofmethicillinresistancestaphylococcusaureusbyorfxloopmediatedisothermalamplificationassay |