Cargando…
Assessment of Regional Ventilation Distribution: Comparison of Vibration Response Imaging (VRI) with Electrical Impedance Tomography (EIT)
BACKGROUND: Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3903564/ https://www.ncbi.nlm.nih.gov/pubmed/24475160 http://dx.doi.org/10.1371/journal.pone.0086638 |
_version_ | 1782301112356831232 |
---|---|
author | Shi, Chang Boehme, Stefan Bentley, Alexander H. Hartmann, Erik K. Klein, Klaus U. Bodenstein, Marc Baumgardner, James E. David, Matthias Ullrich, Roman Markstaller, Klaus |
author_facet | Shi, Chang Boehme, Stefan Bentley, Alexander H. Hartmann, Erik K. Klein, Klaus U. Bodenstein, Marc Baumgardner, James E. David, Matthias Ullrich, Roman Markstaller, Klaus |
author_sort | Shi, Chang |
collection | PubMed |
description | BACKGROUND: Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. METHODOLOGY/PRINCIPAL FINDINGS: Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) by EIT, were evaluated in seven regions of interest (ROIs). To assess the distribution of tidal volume (V(T)) by VRI and EIT, absolute values were normalized to the V(T) obtained by simultaneous spirometry measurements. Redistribution of ventilation by ALI and PEEP was detected by VRI and EIT. The linear correlation between pooled V(T) by VEA and rel.ΔZ was R(2) = 0.96. Bland-Altman analysis showed a bias of −1.07±24.71 ml and limits of agreement of −49.05 to +47.36 ml. Within the different ROIs, correlations of V(T)-distribution by EIT and VRI ranged between R(2) values of 0.29 and 0.96. ALI and PEEP did not alter the agreement of V(T) between VRI and EIT. CONCLUSIONS/SIGNIFICANCE: Measurements of regional ventilation distribution by VRI are comparable to those obtained by EIT. |
format | Online Article Text |
id | pubmed-3903564 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-39035642014-01-28 Assessment of Regional Ventilation Distribution: Comparison of Vibration Response Imaging (VRI) with Electrical Impedance Tomography (EIT) Shi, Chang Boehme, Stefan Bentley, Alexander H. Hartmann, Erik K. Klein, Klaus U. Bodenstein, Marc Baumgardner, James E. David, Matthias Ullrich, Roman Markstaller, Klaus PLoS One Research Article BACKGROUND: Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. METHODOLOGY/PRINCIPAL FINDINGS: Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) by EIT, were evaluated in seven regions of interest (ROIs). To assess the distribution of tidal volume (V(T)) by VRI and EIT, absolute values were normalized to the V(T) obtained by simultaneous spirometry measurements. Redistribution of ventilation by ALI and PEEP was detected by VRI and EIT. The linear correlation between pooled V(T) by VEA and rel.ΔZ was R(2) = 0.96. Bland-Altman analysis showed a bias of −1.07±24.71 ml and limits of agreement of −49.05 to +47.36 ml. Within the different ROIs, correlations of V(T)-distribution by EIT and VRI ranged between R(2) values of 0.29 and 0.96. ALI and PEEP did not alter the agreement of V(T) between VRI and EIT. CONCLUSIONS/SIGNIFICANCE: Measurements of regional ventilation distribution by VRI are comparable to those obtained by EIT. Public Library of Science 2014-01-27 /pmc/articles/PMC3903564/ /pubmed/24475160 http://dx.doi.org/10.1371/journal.pone.0086638 Text en © 2014 Shi et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Shi, Chang Boehme, Stefan Bentley, Alexander H. Hartmann, Erik K. Klein, Klaus U. Bodenstein, Marc Baumgardner, James E. David, Matthias Ullrich, Roman Markstaller, Klaus Assessment of Regional Ventilation Distribution: Comparison of Vibration Response Imaging (VRI) with Electrical Impedance Tomography (EIT) |
title | Assessment of Regional Ventilation Distribution: Comparison of Vibration Response Imaging (VRI) with Electrical Impedance Tomography (EIT) |
title_full | Assessment of Regional Ventilation Distribution: Comparison of Vibration Response Imaging (VRI) with Electrical Impedance Tomography (EIT) |
title_fullStr | Assessment of Regional Ventilation Distribution: Comparison of Vibration Response Imaging (VRI) with Electrical Impedance Tomography (EIT) |
title_full_unstemmed | Assessment of Regional Ventilation Distribution: Comparison of Vibration Response Imaging (VRI) with Electrical Impedance Tomography (EIT) |
title_short | Assessment of Regional Ventilation Distribution: Comparison of Vibration Response Imaging (VRI) with Electrical Impedance Tomography (EIT) |
title_sort | assessment of regional ventilation distribution: comparison of vibration response imaging (vri) with electrical impedance tomography (eit) |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3903564/ https://www.ncbi.nlm.nih.gov/pubmed/24475160 http://dx.doi.org/10.1371/journal.pone.0086638 |
work_keys_str_mv | AT shichang assessmentofregionalventilationdistributioncomparisonofvibrationresponseimagingvriwithelectricalimpedancetomographyeit AT boehmestefan assessmentofregionalventilationdistributioncomparisonofvibrationresponseimagingvriwithelectricalimpedancetomographyeit AT bentleyalexanderh assessmentofregionalventilationdistributioncomparisonofvibrationresponseimagingvriwithelectricalimpedancetomographyeit AT hartmannerikk assessmentofregionalventilationdistributioncomparisonofvibrationresponseimagingvriwithelectricalimpedancetomographyeit AT kleinklausu assessmentofregionalventilationdistributioncomparisonofvibrationresponseimagingvriwithelectricalimpedancetomographyeit AT bodensteinmarc assessmentofregionalventilationdistributioncomparisonofvibrationresponseimagingvriwithelectricalimpedancetomographyeit AT baumgardnerjamese assessmentofregionalventilationdistributioncomparisonofvibrationresponseimagingvriwithelectricalimpedancetomographyeit AT davidmatthias assessmentofregionalventilationdistributioncomparisonofvibrationresponseimagingvriwithelectricalimpedancetomographyeit AT ullrichroman assessmentofregionalventilationdistributioncomparisonofvibrationresponseimagingvriwithelectricalimpedancetomographyeit AT markstallerklaus assessmentofregionalventilationdistributioncomparisonofvibrationresponseimagingvriwithelectricalimpedancetomographyeit |