Cargando…
Determination of the median nerve residual latency values in the diagnosis of carpal tunnel syndrome in comparison with other electrodiagnostic parameters
BACKGROUND: Along with conventional electrodiagnostic studies, several other indexes including residual latency (RL) were introduced in patients with different types of peripheral neuropathies. RL is the time difference between measured and predicted distal conduction times. This study was performed...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3906782/ https://www.ncbi.nlm.nih.gov/pubmed/24523779 |
_version_ | 1782301523404914688 |
---|---|
author | Khosrawi, Saeid Dehghan, Farnaz |
author_facet | Khosrawi, Saeid Dehghan, Farnaz |
author_sort | Khosrawi, Saeid |
collection | PubMed |
description | BACKGROUND: Along with conventional electrodiagnostic studies, several other indexes including residual latency (RL) were introduced in patients with different types of peripheral neuropathies. RL is the time difference between measured and predicted distal conduction times. This study was performed to determine the values of the median nerve RL and to investigate its sensitivity and specificity in the diagnosis of carpal tunnel syndrome (CTS). MATERIALS AND METHODS: The study was carried out among 100 hands of 75 healthy volunteers and 64 patients who had a positive history of pain or paresthesia in upper extremities and 2 of 3 signs suggesting CTS. Information including age, gender and results of sensory and motor nerve conduction velocity, compound motor action potential of proximal and distal stimulation and RL were recorded for analysis. RESULTS: Normal range of the median nerve RL was found to be 1.03-2.65 (mean = 1.84 ± 0.41). The cut-off point of median RL was 2.37 for CTS diagnosis with sensitivity of 85.9% (95% of confidence interval [CI]: 84.4-87.5%) and specificity of 91.1% (95% CI: 87.8-92.2%). CONCLUSION: In mild cases of CTS, which conventional nerve conduction studies (NCSs) shows abnormalities only in sensory studies, RL may better demonstrate the effect on the median nerve motor fibers. We conclude that RL measurement of the median nerve may raise the sensitivity of NCSs for the diagnosis of CTS. |
format | Online Article Text |
id | pubmed-3906782 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-39067822014-02-12 Determination of the median nerve residual latency values in the diagnosis of carpal tunnel syndrome in comparison with other electrodiagnostic parameters Khosrawi, Saeid Dehghan, Farnaz J Res Med Sci Original Article BACKGROUND: Along with conventional electrodiagnostic studies, several other indexes including residual latency (RL) were introduced in patients with different types of peripheral neuropathies. RL is the time difference between measured and predicted distal conduction times. This study was performed to determine the values of the median nerve RL and to investigate its sensitivity and specificity in the diagnosis of carpal tunnel syndrome (CTS). MATERIALS AND METHODS: The study was carried out among 100 hands of 75 healthy volunteers and 64 patients who had a positive history of pain or paresthesia in upper extremities and 2 of 3 signs suggesting CTS. Information including age, gender and results of sensory and motor nerve conduction velocity, compound motor action potential of proximal and distal stimulation and RL were recorded for analysis. RESULTS: Normal range of the median nerve RL was found to be 1.03-2.65 (mean = 1.84 ± 0.41). The cut-off point of median RL was 2.37 for CTS diagnosis with sensitivity of 85.9% (95% of confidence interval [CI]: 84.4-87.5%) and specificity of 91.1% (95% CI: 87.8-92.2%). CONCLUSION: In mild cases of CTS, which conventional nerve conduction studies (NCSs) shows abnormalities only in sensory studies, RL may better demonstrate the effect on the median nerve motor fibers. We conclude that RL measurement of the median nerve may raise the sensitivity of NCSs for the diagnosis of CTS. Medknow Publications & Media Pvt Ltd 2013-11 /pmc/articles/PMC3906782/ /pubmed/24523779 Text en Copyright: © Journal of Research in Medical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Khosrawi, Saeid Dehghan, Farnaz Determination of the median nerve residual latency values in the diagnosis of carpal tunnel syndrome in comparison with other electrodiagnostic parameters |
title | Determination of the median nerve residual latency values in the diagnosis of carpal tunnel syndrome in comparison with other electrodiagnostic parameters |
title_full | Determination of the median nerve residual latency values in the diagnosis of carpal tunnel syndrome in comparison with other electrodiagnostic parameters |
title_fullStr | Determination of the median nerve residual latency values in the diagnosis of carpal tunnel syndrome in comparison with other electrodiagnostic parameters |
title_full_unstemmed | Determination of the median nerve residual latency values in the diagnosis of carpal tunnel syndrome in comparison with other electrodiagnostic parameters |
title_short | Determination of the median nerve residual latency values in the diagnosis of carpal tunnel syndrome in comparison with other electrodiagnostic parameters |
title_sort | determination of the median nerve residual latency values in the diagnosis of carpal tunnel syndrome in comparison with other electrodiagnostic parameters |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3906782/ https://www.ncbi.nlm.nih.gov/pubmed/24523779 |
work_keys_str_mv | AT khosrawisaeid determinationofthemediannerveresiduallatencyvaluesinthediagnosisofcarpaltunnelsyndromeincomparisonwithotherelectrodiagnosticparameters AT dehghanfarnaz determinationofthemediannerveresiduallatencyvaluesinthediagnosisofcarpaltunnelsyndromeincomparisonwithotherelectrodiagnosticparameters |