Cargando…

Optimal z-axis scanning parameters for gynecologic cytology specimens

BACKGROUND: The use of virtual microscopy (VM) in clinical cytology has been limited due to the inability to focus through three dimensional (3D) cell clusters with a single focal plane (2D images). Limited information exists regarding the optimal scanning parameters for 3D scanning. AIMS: The purpo...

Descripción completa

Detalles Bibliográficos
Autores principales: Donnelly, Amber D., Mukherjee, Maheswari S., Lyden, Elizabeth R., Bridge, Julia A., Lele, Subodh M., Wright, Najia, McGaughey, Mary F., Culberson, Alicia M., Horn, Adam J., Wedel, Whitney R., Radio, Stanley J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3908726/
https://www.ncbi.nlm.nih.gov/pubmed/24524004
http://dx.doi.org/10.4103/2153-3539.124015
_version_ 1782301737950904320
author Donnelly, Amber D.
Mukherjee, Maheswari S.
Lyden, Elizabeth R.
Bridge, Julia A.
Lele, Subodh M.
Wright, Najia
McGaughey, Mary F.
Culberson, Alicia M.
Horn, Adam J.
Wedel, Whitney R.
Radio, Stanley J.
author_facet Donnelly, Amber D.
Mukherjee, Maheswari S.
Lyden, Elizabeth R.
Bridge, Julia A.
Lele, Subodh M.
Wright, Najia
McGaughey, Mary F.
Culberson, Alicia M.
Horn, Adam J.
Wedel, Whitney R.
Radio, Stanley J.
author_sort Donnelly, Amber D.
collection PubMed
description BACKGROUND: The use of virtual microscopy (VM) in clinical cytology has been limited due to the inability to focus through three dimensional (3D) cell clusters with a single focal plane (2D images). Limited information exists regarding the optimal scanning parameters for 3D scanning. AIMS: The purpose of this study was to determine the optimal number of the focal plane levels and the optimal scanning interval to digitize gynecological (GYN) specimens prepared on SurePath™ glass slides while maintaining a manageable file size. SUBJECTS AND METHODS: The iScanCoreo Au scanner (Ventana, AZ, USA) was used to digitize 192 SurePath™ glass slides at three focal plane levels at 1 μ interval. The digitized virtual images (VI) were annotated using BioImagene's Image Viewer. Five participants interpreted the VI and recorded the focal plane level at which they felt confident and later interpreted the corresponding glass slide specimens using light microscopy (LM). The participants completed a survey about their experiences. Inter-rater agreement and concordance between the VI and the glass slide specimens were evaluated. RESULTS: This study determined an overall high intra-rater diagnostic concordance between glass and VI (89-97%), however, the inter-rater agreement for all cases was higher for LM (94%) compared with VM (82%). Survey results indicate participants found low grade dysplasia and koilocytes easy to diagnose using three focal plane levels, the image enhancement tool was useful and focusing through the cells helped with interpretation; however, the participants found VI with hyperchromatic crowded groups challenging to interpret. Participants reported they prefer using LM over VM. This study supports using three focal plane levels and 1 μ interval to expand the use of VM in GYN cytology. CONCLUSION: Future improvements in technology and appropriate training should make this format a more preferable and practical option in clinical cytology.
format Online
Article
Text
id pubmed-3908726
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-39087262014-02-12 Optimal z-axis scanning parameters for gynecologic cytology specimens Donnelly, Amber D. Mukherjee, Maheswari S. Lyden, Elizabeth R. Bridge, Julia A. Lele, Subodh M. Wright, Najia McGaughey, Mary F. Culberson, Alicia M. Horn, Adam J. Wedel, Whitney R. Radio, Stanley J. J Pathol Inform Research Article BACKGROUND: The use of virtual microscopy (VM) in clinical cytology has been limited due to the inability to focus through three dimensional (3D) cell clusters with a single focal plane (2D images). Limited information exists regarding the optimal scanning parameters for 3D scanning. AIMS: The purpose of this study was to determine the optimal number of the focal plane levels and the optimal scanning interval to digitize gynecological (GYN) specimens prepared on SurePath™ glass slides while maintaining a manageable file size. SUBJECTS AND METHODS: The iScanCoreo Au scanner (Ventana, AZ, USA) was used to digitize 192 SurePath™ glass slides at three focal plane levels at 1 μ interval. The digitized virtual images (VI) were annotated using BioImagene's Image Viewer. Five participants interpreted the VI and recorded the focal plane level at which they felt confident and later interpreted the corresponding glass slide specimens using light microscopy (LM). The participants completed a survey about their experiences. Inter-rater agreement and concordance between the VI and the glass slide specimens were evaluated. RESULTS: This study determined an overall high intra-rater diagnostic concordance between glass and VI (89-97%), however, the inter-rater agreement for all cases was higher for LM (94%) compared with VM (82%). Survey results indicate participants found low grade dysplasia and koilocytes easy to diagnose using three focal plane levels, the image enhancement tool was useful and focusing through the cells helped with interpretation; however, the participants found VI with hyperchromatic crowded groups challenging to interpret. Participants reported they prefer using LM over VM. This study supports using three focal plane levels and 1 μ interval to expand the use of VM in GYN cytology. CONCLUSION: Future improvements in technology and appropriate training should make this format a more preferable and practical option in clinical cytology. Medknow Publications & Media Pvt Ltd 2013-12-31 /pmc/articles/PMC3908726/ /pubmed/24524004 http://dx.doi.org/10.4103/2153-3539.124015 Text en Copyright: © Donnelly AD http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Donnelly, Amber D.
Mukherjee, Maheswari S.
Lyden, Elizabeth R.
Bridge, Julia A.
Lele, Subodh M.
Wright, Najia
McGaughey, Mary F.
Culberson, Alicia M.
Horn, Adam J.
Wedel, Whitney R.
Radio, Stanley J.
Optimal z-axis scanning parameters for gynecologic cytology specimens
title Optimal z-axis scanning parameters for gynecologic cytology specimens
title_full Optimal z-axis scanning parameters for gynecologic cytology specimens
title_fullStr Optimal z-axis scanning parameters for gynecologic cytology specimens
title_full_unstemmed Optimal z-axis scanning parameters for gynecologic cytology specimens
title_short Optimal z-axis scanning parameters for gynecologic cytology specimens
title_sort optimal z-axis scanning parameters for gynecologic cytology specimens
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3908726/
https://www.ncbi.nlm.nih.gov/pubmed/24524004
http://dx.doi.org/10.4103/2153-3539.124015
work_keys_str_mv AT donnellyamberd optimalzaxisscanningparametersforgynecologiccytologyspecimens
AT mukherjeemaheswaris optimalzaxisscanningparametersforgynecologiccytologyspecimens
AT lydenelizabethr optimalzaxisscanningparametersforgynecologiccytologyspecimens
AT bridgejuliaa optimalzaxisscanningparametersforgynecologiccytologyspecimens
AT lelesubodhm optimalzaxisscanningparametersforgynecologiccytologyspecimens
AT wrightnajia optimalzaxisscanningparametersforgynecologiccytologyspecimens
AT mcgaugheymaryf optimalzaxisscanningparametersforgynecologiccytologyspecimens
AT culbersonaliciam optimalzaxisscanningparametersforgynecologiccytologyspecimens
AT hornadamj optimalzaxisscanningparametersforgynecologiccytologyspecimens
AT wedelwhitneyr optimalzaxisscanningparametersforgynecologiccytologyspecimens
AT radiostanleyj optimalzaxisscanningparametersforgynecologiccytologyspecimens