Cargando…
Time-of-Flight Magnetic Resonance Angiography for Follow-Up of Coil Embolization with Enterprise Stent for Intracranial Aneurysm: Usefulness of Source Images
OBJECTIVE: The aim of this study was to determine the interobserver and intermodality agreement in the interpretation of time-of-flight (TOF) MR angiography (MRA) for the follow-up of coiled intracranial aneurysms with the Enterprise stent. MATERIALS AND METHODS: Two experienced neurointerventionist...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3909851/ https://www.ncbi.nlm.nih.gov/pubmed/24497808 http://dx.doi.org/10.3348/kjr.2014.15.1.161 |
_version_ | 1782301901295976448 |
---|---|
author | Cho, Young Dae Kim, Kang Min Lee, Woong Jae Sohn, Chul-Ho Kang, Hyun-Seung Kim, Jeong Eun Han, Moon Hee |
author_facet | Cho, Young Dae Kim, Kang Min Lee, Woong Jae Sohn, Chul-Ho Kang, Hyun-Seung Kim, Jeong Eun Han, Moon Hee |
author_sort | Cho, Young Dae |
collection | PubMed |
description | OBJECTIVE: The aim of this study was to determine the interobserver and intermodality agreement in the interpretation of time-of-flight (TOF) MR angiography (MRA) for the follow-up of coiled intracranial aneurysms with the Enterprise stent. MATERIALS AND METHODS: Two experienced neurointerventionists independently reviewed the follow-up MRA studies of 40 consecutive patients with 44 coiled aneurysms. All aneurysms were treated with assistance from the Enterprise stent and the radiologic follow-up intervals were greater than 6 months after the endovascular therapy. Digital subtraction angiography (DSA) served as the reference standard. The degree of aneurysm occlusion was determined by an evaluation of the maximal intensity projection (MIP) and source images (SI) of the TOF MRA. The capability of the TOF MRA to depict the residual flow within the coiled aneurysms and the stented parent arteries was compared with that of the DSA. RESULTS: DSA showed stable occlusions in 25 aneurysms, minor recanalization in 8, and major recanalization in 11. Comparisons between the TOF MRA and conventional angiography showed that the MIP plus SI had almost perfect agreement (κ = 0.892, range 0.767 to 1.000) and had better agreement than with the MIP images only (κ = 0.598, range 0.370 to 0.826). In-stent stenosis of more than 33% was observed in 5 cases. Both MIP and SI of the MRA showed poor depiction of in-stent stenosis compared with the DSA. CONCLUSION: TOF MRA seemed to be reliable in screening for aneurysm recurrence after coil embolization with Enterprise stent assistance, especially in the evaluation of the SI, in addition to MIP images in the TOF MRA. |
format | Online Article Text |
id | pubmed-3909851 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-39098512014-02-04 Time-of-Flight Magnetic Resonance Angiography for Follow-Up of Coil Embolization with Enterprise Stent for Intracranial Aneurysm: Usefulness of Source Images Cho, Young Dae Kim, Kang Min Lee, Woong Jae Sohn, Chul-Ho Kang, Hyun-Seung Kim, Jeong Eun Han, Moon Hee Korean J Radiol Neurointervention OBJECTIVE: The aim of this study was to determine the interobserver and intermodality agreement in the interpretation of time-of-flight (TOF) MR angiography (MRA) for the follow-up of coiled intracranial aneurysms with the Enterprise stent. MATERIALS AND METHODS: Two experienced neurointerventionists independently reviewed the follow-up MRA studies of 40 consecutive patients with 44 coiled aneurysms. All aneurysms were treated with assistance from the Enterprise stent and the radiologic follow-up intervals were greater than 6 months after the endovascular therapy. Digital subtraction angiography (DSA) served as the reference standard. The degree of aneurysm occlusion was determined by an evaluation of the maximal intensity projection (MIP) and source images (SI) of the TOF MRA. The capability of the TOF MRA to depict the residual flow within the coiled aneurysms and the stented parent arteries was compared with that of the DSA. RESULTS: DSA showed stable occlusions in 25 aneurysms, minor recanalization in 8, and major recanalization in 11. Comparisons between the TOF MRA and conventional angiography showed that the MIP plus SI had almost perfect agreement (κ = 0.892, range 0.767 to 1.000) and had better agreement than with the MIP images only (κ = 0.598, range 0.370 to 0.826). In-stent stenosis of more than 33% was observed in 5 cases. Both MIP and SI of the MRA showed poor depiction of in-stent stenosis compared with the DSA. CONCLUSION: TOF MRA seemed to be reliable in screening for aneurysm recurrence after coil embolization with Enterprise stent assistance, especially in the evaluation of the SI, in addition to MIP images in the TOF MRA. The Korean Society of Radiology 2014 2014-01-08 /pmc/articles/PMC3909851/ /pubmed/24497808 http://dx.doi.org/10.3348/kjr.2014.15.1.161 Text en Copyright © 2014 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Neurointervention Cho, Young Dae Kim, Kang Min Lee, Woong Jae Sohn, Chul-Ho Kang, Hyun-Seung Kim, Jeong Eun Han, Moon Hee Time-of-Flight Magnetic Resonance Angiography for Follow-Up of Coil Embolization with Enterprise Stent for Intracranial Aneurysm: Usefulness of Source Images |
title | Time-of-Flight Magnetic Resonance Angiography for Follow-Up of Coil Embolization with Enterprise Stent for Intracranial Aneurysm: Usefulness of Source Images |
title_full | Time-of-Flight Magnetic Resonance Angiography for Follow-Up of Coil Embolization with Enterprise Stent for Intracranial Aneurysm: Usefulness of Source Images |
title_fullStr | Time-of-Flight Magnetic Resonance Angiography for Follow-Up of Coil Embolization with Enterprise Stent for Intracranial Aneurysm: Usefulness of Source Images |
title_full_unstemmed | Time-of-Flight Magnetic Resonance Angiography for Follow-Up of Coil Embolization with Enterprise Stent for Intracranial Aneurysm: Usefulness of Source Images |
title_short | Time-of-Flight Magnetic Resonance Angiography for Follow-Up of Coil Embolization with Enterprise Stent for Intracranial Aneurysm: Usefulness of Source Images |
title_sort | time-of-flight magnetic resonance angiography for follow-up of coil embolization with enterprise stent for intracranial aneurysm: usefulness of source images |
topic | Neurointervention |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3909851/ https://www.ncbi.nlm.nih.gov/pubmed/24497808 http://dx.doi.org/10.3348/kjr.2014.15.1.161 |
work_keys_str_mv | AT choyoungdae timeofflightmagneticresonanceangiographyforfollowupofcoilembolizationwithenterprisestentforintracranialaneurysmusefulnessofsourceimages AT kimkangmin timeofflightmagneticresonanceangiographyforfollowupofcoilembolizationwithenterprisestentforintracranialaneurysmusefulnessofsourceimages AT leewoongjae timeofflightmagneticresonanceangiographyforfollowupofcoilembolizationwithenterprisestentforintracranialaneurysmusefulnessofsourceimages AT sohnchulho timeofflightmagneticresonanceangiographyforfollowupofcoilembolizationwithenterprisestentforintracranialaneurysmusefulnessofsourceimages AT kanghyunseung timeofflightmagneticresonanceangiographyforfollowupofcoilembolizationwithenterprisestentforintracranialaneurysmusefulnessofsourceimages AT kimjeongeun timeofflightmagneticresonanceangiographyforfollowupofcoilembolizationwithenterprisestentforintracranialaneurysmusefulnessofsourceimages AT hanmoonhee timeofflightmagneticresonanceangiographyforfollowupofcoilembolizationwithenterprisestentforintracranialaneurysmusefulnessofsourceimages |