Evaluation of the Petrifilm™ EB and TEMPO(®) EB systems with ISO 21528-2:2004 method for the count of Enterobacteriaceae in milk

The development of alternative microbiological techniques is driven by the necessity to meet the current needs to deliver rapid results in the manufacturing process of foods, but it is important that these methods be evaluated for each application. The objective of the present study was to assess th...

Descripción completa

Detalles Bibliográficos
Autores principales: Cirolini, Andréia, Miotto, Marília, Machado, Fernanda Morgana, da Silva, Helen Silvestre, Ogliari, Paulo José, Vieira, Cleide Rosana Werneck
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Brazilian Society of Microbiology 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3910187/
https://www.ncbi.nlm.nih.gov/pubmed/24516444
Descripción
Sumario:The development of alternative microbiological techniques is driven by the necessity to meet the current needs to deliver rapid results in the manufacturing process of foods, but it is important that these methods be evaluated for each application. The objective of the present study was to assess the Petrifilm™ EB and the TEMPO(®) EB systems with ISO 21528-2:2004 for the count of Enterobacteriaceae in pasteurized and UHT milk samples. We analyzed the microflora of 141 pasteurized milk samples, 15 samples of artificially contaminated pasteurized milk and 15 samples of artificially contaminated UHT milk. Investigation of the method Petrifilm™ EB and ISO 21528:2 regression analysis showed a high correlation in the samples, r = 0.90 for the microflora of pasteurized milk, r = 0.98 for artificially contaminated pasteurized milk and r = 0.99 for the artificially contaminated UHT milk. In evaluating the system TEMPO EB ® method and ISO 21528:2 correlation was also significant in the analyzed samples, with r = 0.86 for the microflora of pasteurized milk, r = 0.96 for artificially contaminated pasteurized milk and r = 0.99 for artificially contaminated UHT milk. No statistically significant differences were observed between the three methods conducted to analyze artificially contaminated pasteurized and UHT milk at three inoculum levels. In conclusion, the Petrifilm™ EB system and the TEMPO(®) EB system may be an alternative to the ISO 21528-2:2004 for the Enterobacteriaceae assay for milk as because of the ease-of-operation and the time reduction achieved for conducting the microbiological assay using these systems.