Cargando…
Assessment of inter- and intra-operator cephalometric tracings on cone beam CT radiographs: comparison of the precision of the cone beam CT versus the latero-lateral radiograph tracing
BACKGROUND: In this study we aimed at quantifying the possible errors which may occur when assessing specific reference planes and linear derivants on cephalometric radiographs traced manually and digitally. Furthermore, we have compared the precision of the tracings according to both the two- and t...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3910229/ https://www.ncbi.nlm.nih.gov/pubmed/24393493 http://dx.doi.org/10.1186/2196-1042-15-1 |
_version_ | 1782301952245235712 |
---|---|
author | Farronato, Giampietro Salvadori, Sara Nolet, Francesca Zoia, Alessandro Farronato, Davide |
author_facet | Farronato, Giampietro Salvadori, Sara Nolet, Francesca Zoia, Alessandro Farronato, Davide |
author_sort | Farronato, Giampietro |
collection | PubMed |
description | BACKGROUND: In this study we aimed at quantifying the possible errors which may occur when assessing specific reference planes and linear derivants on cephalometric radiographs traced manually and digitally. Furthermore, we have compared the precision of the tracings according to both the two- and three-dimensional (2D and 3D respectively) techniques and between clinicians. FINDINGS: We have obtained via cone beam computed tomography (CBCT) archive of the orthodontics department of the University of Milan 20 cone beam CT radiographs from which we have obtained 20 latero-lateral radiographs. Five independent clinicians referred to as A, B, C, D, E have been randomly selected to trace both radiographs maintaining the same working and lighting conditions to minimize the possibility of operator- and environment-dependent errors from occurring. The results have been statistically assessed by Student’s t test. The comparison of the data gathered from the tracings in 2D and 3D shows that certain measurements have statistically significant differences. Particularly, the difference in the measurements of the sagittal dimension of the mandible and the anterior and posterior nasal spines has resulted to be statistically significant. The results of the intra-operator comparison proved that the 3D technique is extremely precise. CONCLUSION: Our study determines that the 3D technique allows to obtain more precise results and with several advantages when compared to the conventional technique such as a true representation of the anatomical structures, less risk of errors occurring due to clinician skills and absence of overlapping anatomical structures. |
format | Online Article Text |
id | pubmed-3910229 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-39102292014-02-04 Assessment of inter- and intra-operator cephalometric tracings on cone beam CT radiographs: comparison of the precision of the cone beam CT versus the latero-lateral radiograph tracing Farronato, Giampietro Salvadori, Sara Nolet, Francesca Zoia, Alessandro Farronato, Davide Prog Orthod Short Report BACKGROUND: In this study we aimed at quantifying the possible errors which may occur when assessing specific reference planes and linear derivants on cephalometric radiographs traced manually and digitally. Furthermore, we have compared the precision of the tracings according to both the two- and three-dimensional (2D and 3D respectively) techniques and between clinicians. FINDINGS: We have obtained via cone beam computed tomography (CBCT) archive of the orthodontics department of the University of Milan 20 cone beam CT radiographs from which we have obtained 20 latero-lateral radiographs. Five independent clinicians referred to as A, B, C, D, E have been randomly selected to trace both radiographs maintaining the same working and lighting conditions to minimize the possibility of operator- and environment-dependent errors from occurring. The results have been statistically assessed by Student’s t test. The comparison of the data gathered from the tracings in 2D and 3D shows that certain measurements have statistically significant differences. Particularly, the difference in the measurements of the sagittal dimension of the mandible and the anterior and posterior nasal spines has resulted to be statistically significant. The results of the intra-operator comparison proved that the 3D technique is extremely precise. CONCLUSION: Our study determines that the 3D technique allows to obtain more precise results and with several advantages when compared to the conventional technique such as a true representation of the anatomical structures, less risk of errors occurring due to clinician skills and absence of overlapping anatomical structures. Springer Berlin Heidelberg 2014-01-06 /pmc/articles/PMC3910229/ /pubmed/24393493 http://dx.doi.org/10.1186/2196-1042-15-1 Text en © Farronato et al.; licensee Springer. 2014 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Short Report Farronato, Giampietro Salvadori, Sara Nolet, Francesca Zoia, Alessandro Farronato, Davide Assessment of inter- and intra-operator cephalometric tracings on cone beam CT radiographs: comparison of the precision of the cone beam CT versus the latero-lateral radiograph tracing |
title | Assessment of inter- and intra-operator cephalometric tracings on cone beam CT radiographs: comparison of the precision of the cone beam CT versus the latero-lateral radiograph tracing |
title_full | Assessment of inter- and intra-operator cephalometric tracings on cone beam CT radiographs: comparison of the precision of the cone beam CT versus the latero-lateral radiograph tracing |
title_fullStr | Assessment of inter- and intra-operator cephalometric tracings on cone beam CT radiographs: comparison of the precision of the cone beam CT versus the latero-lateral radiograph tracing |
title_full_unstemmed | Assessment of inter- and intra-operator cephalometric tracings on cone beam CT radiographs: comparison of the precision of the cone beam CT versus the latero-lateral radiograph tracing |
title_short | Assessment of inter- and intra-operator cephalometric tracings on cone beam CT radiographs: comparison of the precision of the cone beam CT versus the latero-lateral radiograph tracing |
title_sort | assessment of inter- and intra-operator cephalometric tracings on cone beam ct radiographs: comparison of the precision of the cone beam ct versus the latero-lateral radiograph tracing |
topic | Short Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3910229/ https://www.ncbi.nlm.nih.gov/pubmed/24393493 http://dx.doi.org/10.1186/2196-1042-15-1 |
work_keys_str_mv | AT farronatogiampietro assessmentofinterandintraoperatorcephalometrictracingsonconebeamctradiographscomparisonoftheprecisionoftheconebeamctversusthelaterolateralradiographtracing AT salvadorisara assessmentofinterandintraoperatorcephalometrictracingsonconebeamctradiographscomparisonoftheprecisionoftheconebeamctversusthelaterolateralradiographtracing AT noletfrancesca assessmentofinterandintraoperatorcephalometrictracingsonconebeamctradiographscomparisonoftheprecisionoftheconebeamctversusthelaterolateralradiographtracing AT zoiaalessandro assessmentofinterandintraoperatorcephalometrictracingsonconebeamctradiographscomparisonoftheprecisionoftheconebeamctversusthelaterolateralradiographtracing AT farronatodavide assessmentofinterandintraoperatorcephalometrictracingsonconebeamctradiographscomparisonoftheprecisionoftheconebeamctversusthelaterolateralradiographtracing |