Cargando…

Short-Term Effect of Standard Automated Perimetry Testing on Intraocular Pressure in Patients with Open-Angle Glaucoma

Purpose. To evaluate the short-term effect of standard automated perimetry (SAP) testing on intraocular pressure (IOP) in patients with open-angle glaucoma (OAG). Methods. We tested 45 patients (71 eyes) with OAG that had stable IOP under medical treatment. IOP was measured four times using an iCare...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Chang Mok, Yoo, Young Cheol
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3914167/
https://www.ncbi.nlm.nih.gov/pubmed/24558609
http://dx.doi.org/10.1155/2013/956504
_version_ 1782302355635568640
author Lee, Chang Mok
Yoo, Young Cheol
author_facet Lee, Chang Mok
Yoo, Young Cheol
author_sort Lee, Chang Mok
collection PubMed
description Purpose. To evaluate the short-term effect of standard automated perimetry (SAP) testing on intraocular pressure (IOP) in patients with open-angle glaucoma (OAG). Methods. We tested 45 patients (71 eyes) with OAG that had stable IOP under medical treatment. IOP was measured four times using an iCare rebound tonometer (RBT) immediately before, immediately after, 10 minutes after, and 20 minutes after SAP testing. Logistic regression analyses were performed to determine the relationships among SAP test duration, mean deviation of the SAP result, type of glaucoma medications, patient age, and significant IOP change (exceeding 2 mmHg) from baseline IOP. Results. The mean baseline IOP was 13.29 ± 3.06 mmHg. Although IOP changes immediately and 20 minutes after SAP testing were not statistically significant, the IOP change 10 minutes after SAP testing (−0.57 ± 1.84 mmHg) was statistically significant. However, the changes were within the margin of error of the RBT. Test duration, mean deviation, patient age, and type of glaucoma medications did not have a significant influence on IOP change (all P > 0.14). Conclusions. IOP measured by RBT did not vary significantly after SAP testing in patients with OAG. It may be not necessary to reject IOP measured after SAP testing in patients with OAG.
format Online
Article
Text
id pubmed-3914167
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-39141672014-02-20 Short-Term Effect of Standard Automated Perimetry Testing on Intraocular Pressure in Patients with Open-Angle Glaucoma Lee, Chang Mok Yoo, Young Cheol ISRN Ophthalmol Clinical Study Purpose. To evaluate the short-term effect of standard automated perimetry (SAP) testing on intraocular pressure (IOP) in patients with open-angle glaucoma (OAG). Methods. We tested 45 patients (71 eyes) with OAG that had stable IOP under medical treatment. IOP was measured four times using an iCare rebound tonometer (RBT) immediately before, immediately after, 10 minutes after, and 20 minutes after SAP testing. Logistic regression analyses were performed to determine the relationships among SAP test duration, mean deviation of the SAP result, type of glaucoma medications, patient age, and significant IOP change (exceeding 2 mmHg) from baseline IOP. Results. The mean baseline IOP was 13.29 ± 3.06 mmHg. Although IOP changes immediately and 20 minutes after SAP testing were not statistically significant, the IOP change 10 minutes after SAP testing (−0.57 ± 1.84 mmHg) was statistically significant. However, the changes were within the margin of error of the RBT. Test duration, mean deviation, patient age, and type of glaucoma medications did not have a significant influence on IOP change (all P > 0.14). Conclusions. IOP measured by RBT did not vary significantly after SAP testing in patients with OAG. It may be not necessary to reject IOP measured after SAP testing in patients with OAG. Hindawi Publishing Corporation 2013-02-14 /pmc/articles/PMC3914167/ /pubmed/24558609 http://dx.doi.org/10.1155/2013/956504 Text en Copyright © 2013 C. M. Lee and Y. C. Yoo. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Lee, Chang Mok
Yoo, Young Cheol
Short-Term Effect of Standard Automated Perimetry Testing on Intraocular Pressure in Patients with Open-Angle Glaucoma
title Short-Term Effect of Standard Automated Perimetry Testing on Intraocular Pressure in Patients with Open-Angle Glaucoma
title_full Short-Term Effect of Standard Automated Perimetry Testing on Intraocular Pressure in Patients with Open-Angle Glaucoma
title_fullStr Short-Term Effect of Standard Automated Perimetry Testing on Intraocular Pressure in Patients with Open-Angle Glaucoma
title_full_unstemmed Short-Term Effect of Standard Automated Perimetry Testing on Intraocular Pressure in Patients with Open-Angle Glaucoma
title_short Short-Term Effect of Standard Automated Perimetry Testing on Intraocular Pressure in Patients with Open-Angle Glaucoma
title_sort short-term effect of standard automated perimetry testing on intraocular pressure in patients with open-angle glaucoma
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3914167/
https://www.ncbi.nlm.nih.gov/pubmed/24558609
http://dx.doi.org/10.1155/2013/956504
work_keys_str_mv AT leechangmok shorttermeffectofstandardautomatedperimetrytestingonintraocularpressureinpatientswithopenangleglaucoma
AT yooyoungcheol shorttermeffectofstandardautomatedperimetrytestingonintraocularpressureinpatientswithopenangleglaucoma