Cargando…

Exercise Intensity and Validity of the Ratings of Perceived Exertion (Borg and OMNI Scales) in an Indoor Cycling Session

The purpose of the study was: 1) to determine the intensity of an indoor cycling session; 2) to know the correlation between the rating of perceived exertion (RPE) scales (Borg and OMNI) and % heart rate reserve (%HRR) with categories; and 3) to evaluate the validity of RPE scales (Borg and OMNI) wi...

Descripción completa

Detalles Bibliográficos
Autor principal: Muyor, José M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Akademia Wychowania Fizycznego w Katowicach 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3916918/
https://www.ncbi.nlm.nih.gov/pubmed/24511345
http://dx.doi.org/10.2478/hukin-2013-0072
_version_ 1782302783186141184
author Muyor, José M.
author_facet Muyor, José M.
author_sort Muyor, José M.
collection PubMed
description The purpose of the study was: 1) to determine the intensity of an indoor cycling session; 2) to know the correlation between the rating of perceived exertion (RPE) scales (Borg and OMNI) and % heart rate reserve (%HRR) with categories; and 3) to evaluate the validity of RPE scales (Borg and OMNI) with respect to the heart rate (HR) and %HRR. A total of fifty-three subjects, 25 males and 28 females (ages: 28.79 ± 6.04 years; body height: 1.71 ± 0.09 m; body mass: 69.59 ± 13.69 kg) were recruited from a private fitness club. All subjects performed the same predesigned indoor cycling session with a total duration of 50 minutes. During the experimental trial, the HR was recorded every 5 s. The Borg 6–20 RPE and OMNI 0–10 scales were used to assess perceived exertion in each phase. The average HR in the cardiovascular phase was 152.24 ± 14.11 b•min-1, the %HRR was 80.62 ± 7.10; and the overall RPE (Borg and OMNI scales) was 14.94 ± 1.11 and 7.18 ± 0.79 points, respectively. The correlation between an average HR and %HRR with Borg and OMNI scales was lower than r = 0.4 (p < 0.05). The correlation value between the Borg and the OMNI RPE scales was r = 0.82 (p < 0.001). It can be concluded that indoor cycling elicits effort of high intensity which could be inappropriate for some participants. The Borg and OMNI scales showed a low validity to quantify the intensity performed in indoor cycling sessions. It indicates the necessity to control the intensity of effort with other instruments to improve efficacy and decrease the risk of overload in this activity.
format Online
Article
Text
id pubmed-3916918
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Akademia Wychowania Fizycznego w Katowicach
record_format MEDLINE/PubMed
spelling pubmed-39169182014-02-07 Exercise Intensity and Validity of the Ratings of Perceived Exertion (Borg and OMNI Scales) in an Indoor Cycling Session Muyor, José M. J Hum Kinet Research Article The purpose of the study was: 1) to determine the intensity of an indoor cycling session; 2) to know the correlation between the rating of perceived exertion (RPE) scales (Borg and OMNI) and % heart rate reserve (%HRR) with categories; and 3) to evaluate the validity of RPE scales (Borg and OMNI) with respect to the heart rate (HR) and %HRR. A total of fifty-three subjects, 25 males and 28 females (ages: 28.79 ± 6.04 years; body height: 1.71 ± 0.09 m; body mass: 69.59 ± 13.69 kg) were recruited from a private fitness club. All subjects performed the same predesigned indoor cycling session with a total duration of 50 minutes. During the experimental trial, the HR was recorded every 5 s. The Borg 6–20 RPE and OMNI 0–10 scales were used to assess perceived exertion in each phase. The average HR in the cardiovascular phase was 152.24 ± 14.11 b•min-1, the %HRR was 80.62 ± 7.10; and the overall RPE (Borg and OMNI scales) was 14.94 ± 1.11 and 7.18 ± 0.79 points, respectively. The correlation between an average HR and %HRR with Borg and OMNI scales was lower than r = 0.4 (p < 0.05). The correlation value between the Borg and the OMNI RPE scales was r = 0.82 (p < 0.001). It can be concluded that indoor cycling elicits effort of high intensity which could be inappropriate for some participants. The Borg and OMNI scales showed a low validity to quantify the intensity performed in indoor cycling sessions. It indicates the necessity to control the intensity of effort with other instruments to improve efficacy and decrease the risk of overload in this activity. Akademia Wychowania Fizycznego w Katowicach 2013-12-31 /pmc/articles/PMC3916918/ /pubmed/24511345 http://dx.doi.org/10.2478/hukin-2013-0072 Text en © Editorial Committee of Journal of Human Kinetics This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Research Article
Muyor, José M.
Exercise Intensity and Validity of the Ratings of Perceived Exertion (Borg and OMNI Scales) in an Indoor Cycling Session
title Exercise Intensity and Validity of the Ratings of Perceived Exertion (Borg and OMNI Scales) in an Indoor Cycling Session
title_full Exercise Intensity and Validity of the Ratings of Perceived Exertion (Borg and OMNI Scales) in an Indoor Cycling Session
title_fullStr Exercise Intensity and Validity of the Ratings of Perceived Exertion (Borg and OMNI Scales) in an Indoor Cycling Session
title_full_unstemmed Exercise Intensity and Validity of the Ratings of Perceived Exertion (Borg and OMNI Scales) in an Indoor Cycling Session
title_short Exercise Intensity and Validity of the Ratings of Perceived Exertion (Borg and OMNI Scales) in an Indoor Cycling Session
title_sort exercise intensity and validity of the ratings of perceived exertion (borg and omni scales) in an indoor cycling session
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3916918/
https://www.ncbi.nlm.nih.gov/pubmed/24511345
http://dx.doi.org/10.2478/hukin-2013-0072
work_keys_str_mv AT muyorjosem exerciseintensityandvalidityoftheratingsofperceivedexertionborgandomniscalesinanindoorcyclingsession