Cargando…

A technique for catheter placement after transurethral resection of the prostate complicated with undermining of the trigone of the bladder

Authors presented 17 patients in whom two techniques for catheterization of the bladder after transurethral resection of the prostate complicated with undermining of the trigone of the bladder were applied. The first maneuver, used in twelve patients, was the insertion of a rigid stylet made from a...

Descripción completa

Detalles Bibliográficos
Autores principales: Szewczyk, Wojciech, Prajsner, Andrzej
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Polish Urological Association 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3921711/
https://www.ncbi.nlm.nih.gov/pubmed/24578876
http://dx.doi.org/10.5173/ceju.2011.02.art13
_version_ 1782303334982483968
author Szewczyk, Wojciech
Prajsner, Andrzej
author_facet Szewczyk, Wojciech
Prajsner, Andrzej
author_sort Szewczyk, Wojciech
collection PubMed
description Authors presented 17 patients in whom two techniques for catheterization of the bladder after transurethral resection of the prostate complicated with undermining of the trigone of the bladder were applied. The first maneuver, used in twelve patients, was the insertion of a rigid stylet made from a 10F pneumatic probe used for percutaneous nephrolithotripsy into the Foley catheter in order to insert the catheter into the bladder in cystoscope manner. In the remaining five patients, the second maneuver was the insertion of a Dufour catheter over the guide wire left in bladder through the resectoscope sheath. These techniques seemed to be easy and safe.
format Online
Article
Text
id pubmed-3921711
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Polish Urological Association
record_format MEDLINE/PubMed
spelling pubmed-39217112014-02-27 A technique for catheter placement after transurethral resection of the prostate complicated with undermining of the trigone of the bladder Szewczyk, Wojciech Prajsner, Andrzej Cent European J Urol Case Reports Authors presented 17 patients in whom two techniques for catheterization of the bladder after transurethral resection of the prostate complicated with undermining of the trigone of the bladder were applied. The first maneuver, used in twelve patients, was the insertion of a rigid stylet made from a 10F pneumatic probe used for percutaneous nephrolithotripsy into the Foley catheter in order to insert the catheter into the bladder in cystoscope manner. In the remaining five patients, the second maneuver was the insertion of a Dufour catheter over the guide wire left in bladder through the resectoscope sheath. These techniques seemed to be easy and safe. Polish Urological Association 2011-06-02 2011 /pmc/articles/PMC3921711/ /pubmed/24578876 http://dx.doi.org/10.5173/ceju.2011.02.art13 Text en Copyright by Polish Urological Association http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Reports
Szewczyk, Wojciech
Prajsner, Andrzej
A technique for catheter placement after transurethral resection of the prostate complicated with undermining of the trigone of the bladder
title A technique for catheter placement after transurethral resection of the prostate complicated with undermining of the trigone of the bladder
title_full A technique for catheter placement after transurethral resection of the prostate complicated with undermining of the trigone of the bladder
title_fullStr A technique for catheter placement after transurethral resection of the prostate complicated with undermining of the trigone of the bladder
title_full_unstemmed A technique for catheter placement after transurethral resection of the prostate complicated with undermining of the trigone of the bladder
title_short A technique for catheter placement after transurethral resection of the prostate complicated with undermining of the trigone of the bladder
title_sort technique for catheter placement after transurethral resection of the prostate complicated with undermining of the trigone of the bladder
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3921711/
https://www.ncbi.nlm.nih.gov/pubmed/24578876
http://dx.doi.org/10.5173/ceju.2011.02.art13
work_keys_str_mv AT szewczykwojciech atechniqueforcatheterplacementaftertransurethralresectionoftheprostatecomplicatedwithunderminingofthetrigoneofthebladder
AT prajsnerandrzej atechniqueforcatheterplacementaftertransurethralresectionoftheprostatecomplicatedwithunderminingofthetrigoneofthebladder
AT szewczykwojciech techniqueforcatheterplacementaftertransurethralresectionoftheprostatecomplicatedwithunderminingofthetrigoneofthebladder
AT prajsnerandrzej techniqueforcatheterplacementaftertransurethralresectionoftheprostatecomplicatedwithunderminingofthetrigoneofthebladder