Cargando…

Analysis of the torque capacity of a completely customized lingual appliance of the next generation

INTRODUCTION: In lingual orthodontic therapy, effective torque control of the incisors is crucial due to the biomechanical particularities associated with the point of force application and the tight link between third order deviations and vertical tooth position. AIM: The aim of the present in vitr...

Descripción completa

Detalles Bibliográficos
Autores principales: Lossdörfer, Stefan, Bieber, Carsten, Schwestka-Polly, Rainer, Wiechmann, Dirk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3922015/
https://www.ncbi.nlm.nih.gov/pubmed/24502426
http://dx.doi.org/10.1186/1746-160X-10-4
_version_ 1782303395828203520
author Lossdörfer, Stefan
Bieber, Carsten
Schwestka-Polly, Rainer
Wiechmann, Dirk
author_facet Lossdörfer, Stefan
Bieber, Carsten
Schwestka-Polly, Rainer
Wiechmann, Dirk
author_sort Lossdörfer, Stefan
collection PubMed
description INTRODUCTION: In lingual orthodontic therapy, effective torque control of the incisors is crucial due to the biomechanical particularities associated with the point of force application and the tight link between third order deviations and vertical tooth position. AIM: The aim of the present in vitro investigation was to analyze the torque capacity of a completely customized lingual appliance of the next generation (WIN) in combination with different finishing archwire dimensions. METHODS: Using a typodont of the upper arch carrying the WIN appliance, slot filling and undersized individualized β-titanium archwires were engaged. Horizontal forces ranging from 0 to 100 cN were applied at the central incisor by means of spring gauges. The resulting angular deviations were recorded and the corresponding torque moments were calculated. RESULTS: For fullsize archwires (0.018”×0.018” β-titanium and 0.018”×0.025” β-titanium), an initial torque play of 0-2° had to be overcome prior to the development of an effective torque moment. Thereafter, a linear correlation between torque angle and torque moment developed for both archwire dimensions with steeper slopes calculated for the specimens with the larger dimension. A torque moment of 2 Nmm required for effective torque correction was noted after a minimum of 2-3° of twist for the 0.018”×0.018” β-titanium wires as compared to 2-4° for the 0.018”×0.025” β-titanium study sample. When undersized archwires were analyzed (0.0175”×0.0175” β-titanium), the measured torque play ranged from 5-7°. After 8-12° of torque angle, the threshold of 2 Nmm was reached. A linear relationship between twist angle and torque moment in which the steepness of the slopes was generally flatter than the ones calculated for the slot filling archwires was noted. CONCLUSIONS: Given the high precision of the bracket slot-archwire-combination provided with the WIN appliance, an effective torque control can be clinically realized.
format Online
Article
Text
id pubmed-3922015
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-39220152014-02-13 Analysis of the torque capacity of a completely customized lingual appliance of the next generation Lossdörfer, Stefan Bieber, Carsten Schwestka-Polly, Rainer Wiechmann, Dirk Head Face Med Research INTRODUCTION: In lingual orthodontic therapy, effective torque control of the incisors is crucial due to the biomechanical particularities associated with the point of force application and the tight link between third order deviations and vertical tooth position. AIM: The aim of the present in vitro investigation was to analyze the torque capacity of a completely customized lingual appliance of the next generation (WIN) in combination with different finishing archwire dimensions. METHODS: Using a typodont of the upper arch carrying the WIN appliance, slot filling and undersized individualized β-titanium archwires were engaged. Horizontal forces ranging from 0 to 100 cN were applied at the central incisor by means of spring gauges. The resulting angular deviations were recorded and the corresponding torque moments were calculated. RESULTS: For fullsize archwires (0.018”×0.018” β-titanium and 0.018”×0.025” β-titanium), an initial torque play of 0-2° had to be overcome prior to the development of an effective torque moment. Thereafter, a linear correlation between torque angle and torque moment developed for both archwire dimensions with steeper slopes calculated for the specimens with the larger dimension. A torque moment of 2 Nmm required for effective torque correction was noted after a minimum of 2-3° of twist for the 0.018”×0.018” β-titanium wires as compared to 2-4° for the 0.018”×0.025” β-titanium study sample. When undersized archwires were analyzed (0.0175”×0.0175” β-titanium), the measured torque play ranged from 5-7°. After 8-12° of torque angle, the threshold of 2 Nmm was reached. A linear relationship between twist angle and torque moment in which the steepness of the slopes was generally flatter than the ones calculated for the slot filling archwires was noted. CONCLUSIONS: Given the high precision of the bracket slot-archwire-combination provided with the WIN appliance, an effective torque control can be clinically realized. BioMed Central 2014-02-07 /pmc/articles/PMC3922015/ /pubmed/24502426 http://dx.doi.org/10.1186/1746-160X-10-4 Text en Copyright © 2014 Lossdörfer et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Lossdörfer, Stefan
Bieber, Carsten
Schwestka-Polly, Rainer
Wiechmann, Dirk
Analysis of the torque capacity of a completely customized lingual appliance of the next generation
title Analysis of the torque capacity of a completely customized lingual appliance of the next generation
title_full Analysis of the torque capacity of a completely customized lingual appliance of the next generation
title_fullStr Analysis of the torque capacity of a completely customized lingual appliance of the next generation
title_full_unstemmed Analysis of the torque capacity of a completely customized lingual appliance of the next generation
title_short Analysis of the torque capacity of a completely customized lingual appliance of the next generation
title_sort analysis of the torque capacity of a completely customized lingual appliance of the next generation
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3922015/
https://www.ncbi.nlm.nih.gov/pubmed/24502426
http://dx.doi.org/10.1186/1746-160X-10-4
work_keys_str_mv AT lossdorferstefan analysisofthetorquecapacityofacompletelycustomizedlingualapplianceofthenextgeneration
AT biebercarsten analysisofthetorquecapacityofacompletelycustomizedlingualapplianceofthenextgeneration
AT schwestkapollyrainer analysisofthetorquecapacityofacompletelycustomizedlingualapplianceofthenextgeneration
AT wiechmanndirk analysisofthetorquecapacityofacompletelycustomizedlingualapplianceofthenextgeneration