Cargando…

Antibody-Capped Mesoporous Nanoscopic Materials: Design of a Probe for the Selective Chromo-Fluorogenic Detection of Finasteride

The synthesis of capped mesoporous silica nanoparticles (MSN) conjugated with an antibody (AB) as a gatekeeper has been carried out in order to obtain a delivery system able to release an entrapped cargo (dye) in the presence of a target molecule (antigen) to which the conjugated antibody binds sele...

Descripción completa

Detalles Bibliográficos
Autores principales: Climent, Estela, Martínez-Máñez, Ramón, Maquieira, Ángel, Sancenón, Félix, Marcos, M Dolores, Brun, Eva M, Soto, Juan, Amorós, Pedro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: WILEY-VCH Verlag 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3922482/
https://www.ncbi.nlm.nih.gov/pubmed/24551515
http://dx.doi.org/10.1002/open.201100008
_version_ 1782303461924143104
author Climent, Estela
Martínez-Máñez, Ramón
Maquieira, Ángel
Sancenón, Félix
Marcos, M Dolores
Brun, Eva M
Soto, Juan
Amorós, Pedro
author_facet Climent, Estela
Martínez-Máñez, Ramón
Maquieira, Ángel
Sancenón, Félix
Marcos, M Dolores
Brun, Eva M
Soto, Juan
Amorós, Pedro
author_sort Climent, Estela
collection PubMed
description The synthesis of capped mesoporous silica nanoparticles (MSN) conjugated with an antibody (AB) as a gatekeeper has been carried out in order to obtain a delivery system able to release an entrapped cargo (dye) in the presence of a target molecule (antigen) to which the conjugated antibody binds selectively. In particular, MSN loaded with rhodamine B and functionalized on the external surface with a suitable derivative of N-(t-butyl)-3-oxo-(5α,17β)-4-aza-androst-1-ene-17-carboxamide (finasteride) have been prepared (S1). The addition of polyclonal antibodies against finasteride induced capping of the pores due to the interaction with the anchored hapten-like finasteride derivative to give a MSN–hapten–AB nanoparticle S1-AB. It was found that the addition of capped material S1-AB to water solutions containing finasteride resulted in displacement of the antibody, pore uncapping and entrapped-dye release. The response of the gated material is highly selective, and only finasteride, among other steroids, was able to induce a significant uncapping process. Compared with finasteride, the finasteride metabolite was able to release 17 % of the dye, whereas the exogen steroids testosterone, metenolone and 16-β-hydroxystanozolol only induced very little release of rhodamine B (lower than 10 %) from aqueous suspensions containing sensing solid S1-AB. A detection limit as low as 20 ppb was found for the fluorimetric detection of finasteride. In order to evaluate a possible application of the material for label-free detection of finasteride, the capped material was isolated and stored to give final sensing solid S1-AB-i. It was found to display a similar behavior towards finasteride as to that shown by freshly prepared S1-AB; even after a period of two months, no significant loss of selectivity or sensitivity was noted. Moreover, to study the application for the detection of finasteride in biological samples, this “aged” material, S1-AB-i, was tested using commercially available blank urine as matrix. Samples containing 70 and 90 % blank urine were spiked with a defined amount of finasteride, and the concentration was determined using capped S1-AB-i. Recovery ranges from 94 % to 118 % were reached.
format Online
Article
Text
id pubmed-3922482
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher WILEY-VCH Verlag
record_format MEDLINE/PubMed
spelling pubmed-39224822014-02-18 Antibody-Capped Mesoporous Nanoscopic Materials: Design of a Probe for the Selective Chromo-Fluorogenic Detection of Finasteride Climent, Estela Martínez-Máñez, Ramón Maquieira, Ángel Sancenón, Félix Marcos, M Dolores Brun, Eva M Soto, Juan Amorós, Pedro ChemistryOpen Full Papers The synthesis of capped mesoporous silica nanoparticles (MSN) conjugated with an antibody (AB) as a gatekeeper has been carried out in order to obtain a delivery system able to release an entrapped cargo (dye) in the presence of a target molecule (antigen) to which the conjugated antibody binds selectively. In particular, MSN loaded with rhodamine B and functionalized on the external surface with a suitable derivative of N-(t-butyl)-3-oxo-(5α,17β)-4-aza-androst-1-ene-17-carboxamide (finasteride) have been prepared (S1). The addition of polyclonal antibodies against finasteride induced capping of the pores due to the interaction with the anchored hapten-like finasteride derivative to give a MSN–hapten–AB nanoparticle S1-AB. It was found that the addition of capped material S1-AB to water solutions containing finasteride resulted in displacement of the antibody, pore uncapping and entrapped-dye release. The response of the gated material is highly selective, and only finasteride, among other steroids, was able to induce a significant uncapping process. Compared with finasteride, the finasteride metabolite was able to release 17 % of the dye, whereas the exogen steroids testosterone, metenolone and 16-β-hydroxystanozolol only induced very little release of rhodamine B (lower than 10 %) from aqueous suspensions containing sensing solid S1-AB. A detection limit as low as 20 ppb was found for the fluorimetric detection of finasteride. In order to evaluate a possible application of the material for label-free detection of finasteride, the capped material was isolated and stored to give final sensing solid S1-AB-i. It was found to display a similar behavior towards finasteride as to that shown by freshly prepared S1-AB; even after a period of two months, no significant loss of selectivity or sensitivity was noted. Moreover, to study the application for the detection of finasteride in biological samples, this “aged” material, S1-AB-i, was tested using commercially available blank urine as matrix. Samples containing 70 and 90 % blank urine were spiked with a defined amount of finasteride, and the concentration was determined using capped S1-AB-i. Recovery ranges from 94 % to 118 % were reached. WILEY-VCH Verlag 2012-12 2012-10-24 /pmc/articles/PMC3922482/ /pubmed/24551515 http://dx.doi.org/10.1002/open.201100008 Text en Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim http://creativecommons.org/licenses/by/2.5/ This is an open access article under the terms of the Creative Commons Attribution Non-Commercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Full Papers
Climent, Estela
Martínez-Máñez, Ramón
Maquieira, Ángel
Sancenón, Félix
Marcos, M Dolores
Brun, Eva M
Soto, Juan
Amorós, Pedro
Antibody-Capped Mesoporous Nanoscopic Materials: Design of a Probe for the Selective Chromo-Fluorogenic Detection of Finasteride
title Antibody-Capped Mesoporous Nanoscopic Materials: Design of a Probe for the Selective Chromo-Fluorogenic Detection of Finasteride
title_full Antibody-Capped Mesoporous Nanoscopic Materials: Design of a Probe for the Selective Chromo-Fluorogenic Detection of Finasteride
title_fullStr Antibody-Capped Mesoporous Nanoscopic Materials: Design of a Probe for the Selective Chromo-Fluorogenic Detection of Finasteride
title_full_unstemmed Antibody-Capped Mesoporous Nanoscopic Materials: Design of a Probe for the Selective Chromo-Fluorogenic Detection of Finasteride
title_short Antibody-Capped Mesoporous Nanoscopic Materials: Design of a Probe for the Selective Chromo-Fluorogenic Detection of Finasteride
title_sort antibody-capped mesoporous nanoscopic materials: design of a probe for the selective chromo-fluorogenic detection of finasteride
topic Full Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3922482/
https://www.ncbi.nlm.nih.gov/pubmed/24551515
http://dx.doi.org/10.1002/open.201100008
work_keys_str_mv AT climentestela antibodycappedmesoporousnanoscopicmaterialsdesignofaprobefortheselectivechromofluorogenicdetectionoffinasteride
AT martinezmanezramon antibodycappedmesoporousnanoscopicmaterialsdesignofaprobefortheselectivechromofluorogenicdetectionoffinasteride
AT maquieiraangel antibodycappedmesoporousnanoscopicmaterialsdesignofaprobefortheselectivechromofluorogenicdetectionoffinasteride
AT sancenonfelix antibodycappedmesoporousnanoscopicmaterialsdesignofaprobefortheselectivechromofluorogenicdetectionoffinasteride
AT marcosmdolores antibodycappedmesoporousnanoscopicmaterialsdesignofaprobefortheselectivechromofluorogenicdetectionoffinasteride
AT brunevam antibodycappedmesoporousnanoscopicmaterialsdesignofaprobefortheselectivechromofluorogenicdetectionoffinasteride
AT sotojuan antibodycappedmesoporousnanoscopicmaterialsdesignofaprobefortheselectivechromofluorogenicdetectionoffinasteride
AT amorospedro antibodycappedmesoporousnanoscopicmaterialsdesignofaprobefortheselectivechromofluorogenicdetectionoffinasteride