Cargando…

Automated measurement of heterogeneity in CT images of healthy and diseased rat lungs using variogram analysis of an octree decomposition

BACKGROUND: Assessing heterogeneity in lung images can be an important diagnosis tool. We present a novel and objective method for assessing lung damage in a rat model of emphysema. We combined a three-dimensional (3D) computer graphics method–octree decomposition–with a geostatistics-based approach...

Descripción completa

Detalles Bibliográficos
Autores principales: Jacob, Richard E, Carson, James P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3922839/
https://www.ncbi.nlm.nih.gov/pubmed/24393332
http://dx.doi.org/10.1186/1471-2342-14-1
_version_ 1782303516615770112
author Jacob, Richard E
Carson, James P
author_facet Jacob, Richard E
Carson, James P
author_sort Jacob, Richard E
collection PubMed
description BACKGROUND: Assessing heterogeneity in lung images can be an important diagnosis tool. We present a novel and objective method for assessing lung damage in a rat model of emphysema. We combined a three-dimensional (3D) computer graphics method–octree decomposition–with a geostatistics-based approach for assessing spatial relationships–the variogram–to evaluate disease in 3D computed tomography (CT) image volumes. METHODS: Male, Sprague-Dawley rats were dosed intratracheally with saline (control), or with elastase dissolved in saline to either the whole lung (for mild, global disease) or a single lobe (for severe, local disease). Gated 3D micro-CT images were acquired on the lungs of all rats at end expiration. Images were masked, and octree decomposition was performed on the images to reduce the lungs to homogeneous blocks of 2 × 2 × 2, 4 × 4 × 4, and 8 × 8 × 8 voxels. To focus on lung parenchyma, small blocks were ignored because they primarily defined boundaries and vascular features, and the spatial variance between all pairs of the 8 × 8 × 8 blocks was calculated as the square of the difference of signal intensity. Variograms–graphs of distance vs. variance–were constructed, and results of a least-squares-fit were compared. The robustness of the approach was tested on images prepared with various filtering protocols. Statistical assessment of the similarity of the three control rats was made with a Kruskal-Wallis rank sum test. A Mann-Whitney-Wilcoxon rank sum test was used to measure statistical distinction between individuals. For comparison with the variogram results, the coefficient of variation and the emphysema index were also calculated for all rats. RESULTS: Variogram analysis showed that the control rats were statistically indistinct (p = 0.12), but there were significant differences between control, mild global disease, and severe local disease groups (p < 0.0001). A heterogeneity index was calculated to describe the difference of an individual variogram from the control average. This metric also showed clear separation between dose groups. The coefficient of variation and the emphysema index, on the other hand, did not separate groups. CONCLUSION: These results suggest the octree decomposition and variogram analysis approach may be a rapid, non-subjective, and sensitive imaging-based biomarker for characterizing lung disease.
format Online
Article
Text
id pubmed-3922839
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-39228392014-02-28 Automated measurement of heterogeneity in CT images of healthy and diseased rat lungs using variogram analysis of an octree decomposition Jacob, Richard E Carson, James P BMC Med Imaging Research Article BACKGROUND: Assessing heterogeneity in lung images can be an important diagnosis tool. We present a novel and objective method for assessing lung damage in a rat model of emphysema. We combined a three-dimensional (3D) computer graphics method–octree decomposition–with a geostatistics-based approach for assessing spatial relationships–the variogram–to evaluate disease in 3D computed tomography (CT) image volumes. METHODS: Male, Sprague-Dawley rats were dosed intratracheally with saline (control), or with elastase dissolved in saline to either the whole lung (for mild, global disease) or a single lobe (for severe, local disease). Gated 3D micro-CT images were acquired on the lungs of all rats at end expiration. Images were masked, and octree decomposition was performed on the images to reduce the lungs to homogeneous blocks of 2 × 2 × 2, 4 × 4 × 4, and 8 × 8 × 8 voxels. To focus on lung parenchyma, small blocks were ignored because they primarily defined boundaries and vascular features, and the spatial variance between all pairs of the 8 × 8 × 8 blocks was calculated as the square of the difference of signal intensity. Variograms–graphs of distance vs. variance–were constructed, and results of a least-squares-fit were compared. The robustness of the approach was tested on images prepared with various filtering protocols. Statistical assessment of the similarity of the three control rats was made with a Kruskal-Wallis rank sum test. A Mann-Whitney-Wilcoxon rank sum test was used to measure statistical distinction between individuals. For comparison with the variogram results, the coefficient of variation and the emphysema index were also calculated for all rats. RESULTS: Variogram analysis showed that the control rats were statistically indistinct (p = 0.12), but there were significant differences between control, mild global disease, and severe local disease groups (p < 0.0001). A heterogeneity index was calculated to describe the difference of an individual variogram from the control average. This metric also showed clear separation between dose groups. The coefficient of variation and the emphysema index, on the other hand, did not separate groups. CONCLUSION: These results suggest the octree decomposition and variogram analysis approach may be a rapid, non-subjective, and sensitive imaging-based biomarker for characterizing lung disease. BioMed Central 2014-01-06 /pmc/articles/PMC3922839/ /pubmed/24393332 http://dx.doi.org/10.1186/1471-2342-14-1 Text en Copyright © 2014 Jacob and Carson; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Jacob, Richard E
Carson, James P
Automated measurement of heterogeneity in CT images of healthy and diseased rat lungs using variogram analysis of an octree decomposition
title Automated measurement of heterogeneity in CT images of healthy and diseased rat lungs using variogram analysis of an octree decomposition
title_full Automated measurement of heterogeneity in CT images of healthy and diseased rat lungs using variogram analysis of an octree decomposition
title_fullStr Automated measurement of heterogeneity in CT images of healthy and diseased rat lungs using variogram analysis of an octree decomposition
title_full_unstemmed Automated measurement of heterogeneity in CT images of healthy and diseased rat lungs using variogram analysis of an octree decomposition
title_short Automated measurement of heterogeneity in CT images of healthy and diseased rat lungs using variogram analysis of an octree decomposition
title_sort automated measurement of heterogeneity in ct images of healthy and diseased rat lungs using variogram analysis of an octree decomposition
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3922839/
https://www.ncbi.nlm.nih.gov/pubmed/24393332
http://dx.doi.org/10.1186/1471-2342-14-1
work_keys_str_mv AT jacobricharde automatedmeasurementofheterogeneityinctimagesofhealthyanddiseasedratlungsusingvariogramanalysisofanoctreedecomposition
AT carsonjamesp automatedmeasurementofheterogeneityinctimagesofhealthyanddiseasedratlungsusingvariogramanalysisofanoctreedecomposition