Cargando…
Interference-Free Determination of Trace Copper in Freshly Ripened Honeys by Flame Atomic Absorption Spectrometry Following a Preconcentration by Solid-Phase Extraction and a Two-Step Elution Process
A fast and straightforward procedure aimed at separating copper (Cu) ions from monosacharides and preconcentrating their traces before flame atomic absorption spectrometry (FAAS) measurements was developed, and its suitability was evaluated by the analysis of freshly ripened honeys on the content of...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3923108/ https://www.ncbi.nlm.nih.gov/pubmed/24165785 http://dx.doi.org/10.1007/s00244-013-9961-x |
_version_ | 1782303562641965056 |
---|---|
author | Pohl, Pawel Stecka, Helena Jamroz, Piotr |
author_facet | Pohl, Pawel Stecka, Helena Jamroz, Piotr |
author_sort | Pohl, Pawel |
collection | PubMed |
description | A fast and straightforward procedure aimed at separating copper (Cu) ions from monosacharides and preconcentrating their traces before flame atomic absorption spectrometry (FAAS) measurements was developed, and its suitability was evaluated by the analysis of freshly ripened honeys on the content of this environmentally and physiologically relevant element. This procedure included the passage (at 20 mL/min) of 10 % (m/v) solutions of honeys (100 mL) through resin beds of Dowex 50 W × 8-400 to retain Cu by solid-phase extraction (SPE) and separate it from the glucose and fructose matrix. In turn, SPE columns were rinsed at 20 mL/min with 20 mL of water and subsequently washed with 20 mL of a 0.5 mol/L HNO(3) solution (at 2.0 mL/min) to elute potassium and sodium. Preconcentrated Cu was stripped (at 2.0 mL/min) with 5.0 mL of a 2.0 mol/L HCl solution and determined by FAAS. The proposed procedure was used for the analysis of six ripened monoflower and multiflower honeys, enabling the measurement of Cu within the range of 0.17–0.42 μg/g and with a precision of 3–10 %. Recoveries of Cu added to respective honey solutions were within 94–102 %, proving the good accuracy of this procedure. The detection limit of Cu achieved with this SPE preconcentration/separation procedure and FAAS detection was 3.6 ng/g. |
format | Online Article Text |
id | pubmed-3923108 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-39231082014-02-24 Interference-Free Determination of Trace Copper in Freshly Ripened Honeys by Flame Atomic Absorption Spectrometry Following a Preconcentration by Solid-Phase Extraction and a Two-Step Elution Process Pohl, Pawel Stecka, Helena Jamroz, Piotr Arch Environ Contam Toxicol Article A fast and straightforward procedure aimed at separating copper (Cu) ions from monosacharides and preconcentrating their traces before flame atomic absorption spectrometry (FAAS) measurements was developed, and its suitability was evaluated by the analysis of freshly ripened honeys on the content of this environmentally and physiologically relevant element. This procedure included the passage (at 20 mL/min) of 10 % (m/v) solutions of honeys (100 mL) through resin beds of Dowex 50 W × 8-400 to retain Cu by solid-phase extraction (SPE) and separate it from the glucose and fructose matrix. In turn, SPE columns were rinsed at 20 mL/min with 20 mL of water and subsequently washed with 20 mL of a 0.5 mol/L HNO(3) solution (at 2.0 mL/min) to elute potassium and sodium. Preconcentrated Cu was stripped (at 2.0 mL/min) with 5.0 mL of a 2.0 mol/L HCl solution and determined by FAAS. The proposed procedure was used for the analysis of six ripened monoflower and multiflower honeys, enabling the measurement of Cu within the range of 0.17–0.42 μg/g and with a precision of 3–10 %. Recoveries of Cu added to respective honey solutions were within 94–102 %, proving the good accuracy of this procedure. The detection limit of Cu achieved with this SPE preconcentration/separation procedure and FAAS detection was 3.6 ng/g. Springer US 2013-10-29 2014 /pmc/articles/PMC3923108/ /pubmed/24165785 http://dx.doi.org/10.1007/s00244-013-9961-x Text en © The Author(s) 2013 https://creativecommons.org/licenses/by/2.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Article Pohl, Pawel Stecka, Helena Jamroz, Piotr Interference-Free Determination of Trace Copper in Freshly Ripened Honeys by Flame Atomic Absorption Spectrometry Following a Preconcentration by Solid-Phase Extraction and a Two-Step Elution Process |
title | Interference-Free Determination of Trace Copper in Freshly Ripened Honeys by Flame Atomic Absorption Spectrometry Following a Preconcentration by Solid-Phase Extraction and a Two-Step Elution Process |
title_full | Interference-Free Determination of Trace Copper in Freshly Ripened Honeys by Flame Atomic Absorption Spectrometry Following a Preconcentration by Solid-Phase Extraction and a Two-Step Elution Process |
title_fullStr | Interference-Free Determination of Trace Copper in Freshly Ripened Honeys by Flame Atomic Absorption Spectrometry Following a Preconcentration by Solid-Phase Extraction and a Two-Step Elution Process |
title_full_unstemmed | Interference-Free Determination of Trace Copper in Freshly Ripened Honeys by Flame Atomic Absorption Spectrometry Following a Preconcentration by Solid-Phase Extraction and a Two-Step Elution Process |
title_short | Interference-Free Determination of Trace Copper in Freshly Ripened Honeys by Flame Atomic Absorption Spectrometry Following a Preconcentration by Solid-Phase Extraction and a Two-Step Elution Process |
title_sort | interference-free determination of trace copper in freshly ripened honeys by flame atomic absorption spectrometry following a preconcentration by solid-phase extraction and a two-step elution process |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3923108/ https://www.ncbi.nlm.nih.gov/pubmed/24165785 http://dx.doi.org/10.1007/s00244-013-9961-x |
work_keys_str_mv | AT pohlpawel interferencefreedeterminationoftracecopperinfreshlyripenedhoneysbyflameatomicabsorptionspectrometryfollowingapreconcentrationbysolidphaseextractionandatwostepelutionprocess AT steckahelena interferencefreedeterminationoftracecopperinfreshlyripenedhoneysbyflameatomicabsorptionspectrometryfollowingapreconcentrationbysolidphaseextractionandatwostepelutionprocess AT jamrozpiotr interferencefreedeterminationoftracecopperinfreshlyripenedhoneysbyflameatomicabsorptionspectrometryfollowingapreconcentrationbysolidphaseextractionandatwostepelutionprocess |