Cargando…

New Estimators and Guidelines for Better Use of Fetal Heart Rate Estimators with Doppler Ultrasound Devices

Characterizing fetal wellbeing with a Doppler ultrasound device requires computation of a score based on fetal parameters. In order to analyze the parameters derived from the fetal heart rate correctly, an accuracy of 0.25 beats per minute is needed. Simultaneously with the lowest false negative rat...

Descripción completa

Detalles Bibliográficos
Autores principales: Voicu, Iulian, Ménigot, Sébastien, Kouamé, Denis, Girault, Jean-Marc
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3926313/
https://www.ncbi.nlm.nih.gov/pubmed/24624224
http://dx.doi.org/10.1155/2014/784862
_version_ 1782303957636349952
author Voicu, Iulian
Ménigot, Sébastien
Kouamé, Denis
Girault, Jean-Marc
author_facet Voicu, Iulian
Ménigot, Sébastien
Kouamé, Denis
Girault, Jean-Marc
author_sort Voicu, Iulian
collection PubMed
description Characterizing fetal wellbeing with a Doppler ultrasound device requires computation of a score based on fetal parameters. In order to analyze the parameters derived from the fetal heart rate correctly, an accuracy of 0.25 beats per minute is needed. Simultaneously with the lowest false negative rate and the highest sensitivity, we investigated whether various Doppler techniques ensure this accuracy. We found that the accuracy was ensured if directional Doppler signals and autocorrelation estimation were used. Our best estimator provided sensitivity of 95.5%, corresponding to an improvement of 14% compared to the standard estimator.
format Online
Article
Text
id pubmed-3926313
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-39263132014-03-12 New Estimators and Guidelines for Better Use of Fetal Heart Rate Estimators with Doppler Ultrasound Devices Voicu, Iulian Ménigot, Sébastien Kouamé, Denis Girault, Jean-Marc Comput Math Methods Med Research Article Characterizing fetal wellbeing with a Doppler ultrasound device requires computation of a score based on fetal parameters. In order to analyze the parameters derived from the fetal heart rate correctly, an accuracy of 0.25 beats per minute is needed. Simultaneously with the lowest false negative rate and the highest sensitivity, we investigated whether various Doppler techniques ensure this accuracy. We found that the accuracy was ensured if directional Doppler signals and autocorrelation estimation were used. Our best estimator provided sensitivity of 95.5%, corresponding to an improvement of 14% compared to the standard estimator. Hindawi Publishing Corporation 2014 2014-01-29 /pmc/articles/PMC3926313/ /pubmed/24624224 http://dx.doi.org/10.1155/2014/784862 Text en Copyright © 2014 Iulian Voicu et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Voicu, Iulian
Ménigot, Sébastien
Kouamé, Denis
Girault, Jean-Marc
New Estimators and Guidelines for Better Use of Fetal Heart Rate Estimators with Doppler Ultrasound Devices
title New Estimators and Guidelines for Better Use of Fetal Heart Rate Estimators with Doppler Ultrasound Devices
title_full New Estimators and Guidelines for Better Use of Fetal Heart Rate Estimators with Doppler Ultrasound Devices
title_fullStr New Estimators and Guidelines for Better Use of Fetal Heart Rate Estimators with Doppler Ultrasound Devices
title_full_unstemmed New Estimators and Guidelines for Better Use of Fetal Heart Rate Estimators with Doppler Ultrasound Devices
title_short New Estimators and Guidelines for Better Use of Fetal Heart Rate Estimators with Doppler Ultrasound Devices
title_sort new estimators and guidelines for better use of fetal heart rate estimators with doppler ultrasound devices
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3926313/
https://www.ncbi.nlm.nih.gov/pubmed/24624224
http://dx.doi.org/10.1155/2014/784862
work_keys_str_mv AT voicuiulian newestimatorsandguidelinesforbetteruseoffetalheartrateestimatorswithdopplerultrasounddevices
AT menigotsebastien newestimatorsandguidelinesforbetteruseoffetalheartrateestimatorswithdopplerultrasounddevices
AT kouamedenis newestimatorsandguidelinesforbetteruseoffetalheartrateestimatorswithdopplerultrasounddevices
AT giraultjeanmarc newestimatorsandguidelinesforbetteruseoffetalheartrateestimatorswithdopplerultrasounddevices