Cargando…
Biosensing Using Microring Resonator Interferograms
Optical low-coherence interferometry (OLCI) takes advantage of the variation in refractive index in silicon-wire microring resonator (MRR) effective lengths to perform glucose biosensing using MRR interferograms. The MRR quality factor (Q), proportional to the effective length, could be improved usi...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3926609/ https://www.ncbi.nlm.nih.gov/pubmed/24434876 http://dx.doi.org/10.3390/s140101184 |
_version_ | 1782303998244552704 |
---|---|
author | Hsu, Shih-Hsiang Yang, Yung-Chia Su, Yu-Hou Wang, Sheng-Min Huang, Shih-An Lin, Ching-Yu |
author_facet | Hsu, Shih-Hsiang Yang, Yung-Chia Su, Yu-Hou Wang, Sheng-Min Huang, Shih-An Lin, Ching-Yu |
author_sort | Hsu, Shih-Hsiang |
collection | PubMed |
description | Optical low-coherence interferometry (OLCI) takes advantage of the variation in refractive index in silicon-wire microring resonator (MRR) effective lengths to perform glucose biosensing using MRR interferograms. The MRR quality factor (Q), proportional to the effective length, could be improved using the silicon-wire propagation loss and coupling ratio from the MRR coupler. Our study showed that multimode interference (MMI) performed well in broad band response, but the splitting ratio drifted to 75/25 due to the stress issue. The glucose sensing sensitivity demonstrated 0.00279 meter per refractive-index-unit (RIU) with a Q factor of ∼30,000 under transverse electric polarization. The 1,310 nm DFB laser was built in the OLCI system as the optical ruler achieving 655 nm characterization accuracy. The lowest sensing limitation was therefore 2 × 10(−4) RIU. Moreover, the MRR effective length from the glucose sensitivity could be utilized to experimentally demonstrate the silicon wire effective refractive index with a width of 0.45 μm and height of 0.26 μm. |
format | Online Article Text |
id | pubmed-3926609 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-39266092014-02-18 Biosensing Using Microring Resonator Interferograms Hsu, Shih-Hsiang Yang, Yung-Chia Su, Yu-Hou Wang, Sheng-Min Huang, Shih-An Lin, Ching-Yu Sensors (Basel) Article Optical low-coherence interferometry (OLCI) takes advantage of the variation in refractive index in silicon-wire microring resonator (MRR) effective lengths to perform glucose biosensing using MRR interferograms. The MRR quality factor (Q), proportional to the effective length, could be improved using the silicon-wire propagation loss and coupling ratio from the MRR coupler. Our study showed that multimode interference (MMI) performed well in broad band response, but the splitting ratio drifted to 75/25 due to the stress issue. The glucose sensing sensitivity demonstrated 0.00279 meter per refractive-index-unit (RIU) with a Q factor of ∼30,000 under transverse electric polarization. The 1,310 nm DFB laser was built in the OLCI system as the optical ruler achieving 655 nm characterization accuracy. The lowest sensing limitation was therefore 2 × 10(−4) RIU. Moreover, the MRR effective length from the glucose sensitivity could be utilized to experimentally demonstrate the silicon wire effective refractive index with a width of 0.45 μm and height of 0.26 μm. Molecular Diversity Preservation International (MDPI) 2014-01-10 /pmc/articles/PMC3926609/ /pubmed/24434876 http://dx.doi.org/10.3390/s140101184 Text en © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Hsu, Shih-Hsiang Yang, Yung-Chia Su, Yu-Hou Wang, Sheng-Min Huang, Shih-An Lin, Ching-Yu Biosensing Using Microring Resonator Interferograms |
title | Biosensing Using Microring Resonator Interferograms |
title_full | Biosensing Using Microring Resonator Interferograms |
title_fullStr | Biosensing Using Microring Resonator Interferograms |
title_full_unstemmed | Biosensing Using Microring Resonator Interferograms |
title_short | Biosensing Using Microring Resonator Interferograms |
title_sort | biosensing using microring resonator interferograms |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3926609/ https://www.ncbi.nlm.nih.gov/pubmed/24434876 http://dx.doi.org/10.3390/s140101184 |
work_keys_str_mv | AT hsushihhsiang biosensingusingmicroringresonatorinterferograms AT yangyungchia biosensingusingmicroringresonatorinterferograms AT suyuhou biosensingusingmicroringresonatorinterferograms AT wangshengmin biosensingusingmicroringresonatorinterferograms AT huangshihan biosensingusingmicroringresonatorinterferograms AT linchingyu biosensingusingmicroringresonatorinterferograms |