Cargando…

Use of Cemented Spacer with a Handmade Stem to Treat Acute Periprosthetic Tibial Fracture Infection: A Case Report

We report an 85-year-old woman with dementia and dependent for normal life activities who was admitted due to a left periprosthetic tibial fracture. The tibial component was replaced by one with a long stem and she was discharged. Four weeks after the intervention the patient was re-admitted due to...

Descripción completa

Detalles Bibliográficos
Autores principales: Font-Vizcarra, LluÍs, Izquierdo, Oscar, GarcÍa-NuÑo, Laura, GonzÁlez, Araceli, Diaz-Brito, VicenÇ, Castellanos, Juan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Open 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3927377/
https://www.ncbi.nlm.nih.gov/pubmed/24551027
http://dx.doi.org/10.2174/1874325001408010024
Descripción
Sumario:We report an 85-year-old woman with dementia and dependent for normal life activities who was admitted due to a left periprosthetic tibial fracture. The tibial component was replaced by one with a long stem and she was discharged. Four weeks after the intervention the patient was re-admitted due to an acute prosthetic joint infection. All the components were removed and a bone-cement spacer with a handmade stem with a metal core was implanted. Radiological signs of fracture consolidation were observed after 3 months of follow-up. Due to the previous health status of the patient, it was decided to keep the spacer as a definitive treatment. After 24 months, the patient was able to sit without pain and to stand up with help using a knee brace. There were no radiological or clinical signs of infection.