Cargando…
Sciatic Nerve Injury Related to Hip Replacement Surgery: Imaging Detection by MR Neurography Despite Susceptibility Artifacts
Sciatic nerve palsy related to hip replacement surgery (HRS) is among the most common causes of sciatic neuropathies. The sciatic nerve may be injured by various different periprocedural mechanisms. The precise localization and extension of the nerve lesion, the determination of nerve continuity, le...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3928432/ https://www.ncbi.nlm.nih.gov/pubmed/24558483 http://dx.doi.org/10.1371/journal.pone.0089154 |
_version_ | 1782304258894331904 |
---|---|
author | Wolf, Marcel Bäumer, Philipp Pedro, Maria Dombert, Thomas Staub, Frank Heiland, Sabine Bendszus, Martin Pham, Mirko |
author_facet | Wolf, Marcel Bäumer, Philipp Pedro, Maria Dombert, Thomas Staub, Frank Heiland, Sabine Bendszus, Martin Pham, Mirko |
author_sort | Wolf, Marcel |
collection | PubMed |
description | Sciatic nerve palsy related to hip replacement surgery (HRS) is among the most common causes of sciatic neuropathies. The sciatic nerve may be injured by various different periprocedural mechanisms. The precise localization and extension of the nerve lesion, the determination of nerve continuity, lesion severity, and fascicular lesion distribution are essential for assessing the potential of spontaneous recovery and thereby avoiding delayed or inappropriate therapy. Adequate therapy is in many cases limited to conservative management, but in certain cases early surgical exploration and release of the nerve is indicated. Nerve-conduction-studies and electromyography are essential in the diagnosis of nerve injuries. In postsurgical nerve injuries, additional diagnostic imaging is important as well, in particular to detect or rule out direct mechanical compromise. Especially in the presence of metallic implants, commonly applied diagnostic imaging tests generally fail to adequately visualize nervous tissue. MRI has been deemed problematic due to implant-related artifacts after HRS. In this study, we describe for the first time the spectrum of imaging findings of Magnetic Resonance neurography (MRN) employing pulse sequences relatively insensitive to susceptibility artifacts (susceptibility insensitive MRN, siMRN) in a series of 9 patients with HRS procedure related sciatic nerve palsy. We were able to determine the localization and fascicular distribution of the sciatic nerve lesion in all 9 patients, which clearly showed on imaging predominant involvement of the peroneal more than the tibial division of the sciatic nerve. In 2 patients siMRN revealed direct mechanical compromise of the nerve by surgical material, and in one of these cases indication for surgical release of the sciatic nerve was based on siMRN. Thus, in selected cases of HRS related neuropathies, especially when surgical exploration of the nerve is considered, siMRN, with its potential to largely overcome implant related artifacts, is a useful diagnostic addition to nerve-conduction-studies and electromyography. |
format | Online Article Text |
id | pubmed-3928432 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-39284322014-02-20 Sciatic Nerve Injury Related to Hip Replacement Surgery: Imaging Detection by MR Neurography Despite Susceptibility Artifacts Wolf, Marcel Bäumer, Philipp Pedro, Maria Dombert, Thomas Staub, Frank Heiland, Sabine Bendszus, Martin Pham, Mirko PLoS One Research Article Sciatic nerve palsy related to hip replacement surgery (HRS) is among the most common causes of sciatic neuropathies. The sciatic nerve may be injured by various different periprocedural mechanisms. The precise localization and extension of the nerve lesion, the determination of nerve continuity, lesion severity, and fascicular lesion distribution are essential for assessing the potential of spontaneous recovery and thereby avoiding delayed or inappropriate therapy. Adequate therapy is in many cases limited to conservative management, but in certain cases early surgical exploration and release of the nerve is indicated. Nerve-conduction-studies and electromyography are essential in the diagnosis of nerve injuries. In postsurgical nerve injuries, additional diagnostic imaging is important as well, in particular to detect or rule out direct mechanical compromise. Especially in the presence of metallic implants, commonly applied diagnostic imaging tests generally fail to adequately visualize nervous tissue. MRI has been deemed problematic due to implant-related artifacts after HRS. In this study, we describe for the first time the spectrum of imaging findings of Magnetic Resonance neurography (MRN) employing pulse sequences relatively insensitive to susceptibility artifacts (susceptibility insensitive MRN, siMRN) in a series of 9 patients with HRS procedure related sciatic nerve palsy. We were able to determine the localization and fascicular distribution of the sciatic nerve lesion in all 9 patients, which clearly showed on imaging predominant involvement of the peroneal more than the tibial division of the sciatic nerve. In 2 patients siMRN revealed direct mechanical compromise of the nerve by surgical material, and in one of these cases indication for surgical release of the sciatic nerve was based on siMRN. Thus, in selected cases of HRS related neuropathies, especially when surgical exploration of the nerve is considered, siMRN, with its potential to largely overcome implant related artifacts, is a useful diagnostic addition to nerve-conduction-studies and electromyography. Public Library of Science 2014-02-18 /pmc/articles/PMC3928432/ /pubmed/24558483 http://dx.doi.org/10.1371/journal.pone.0089154 Text en © 2014 Wolf et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Wolf, Marcel Bäumer, Philipp Pedro, Maria Dombert, Thomas Staub, Frank Heiland, Sabine Bendszus, Martin Pham, Mirko Sciatic Nerve Injury Related to Hip Replacement Surgery: Imaging Detection by MR Neurography Despite Susceptibility Artifacts |
title | Sciatic Nerve Injury Related to Hip Replacement Surgery: Imaging Detection by MR Neurography Despite Susceptibility Artifacts |
title_full | Sciatic Nerve Injury Related to Hip Replacement Surgery: Imaging Detection by MR Neurography Despite Susceptibility Artifacts |
title_fullStr | Sciatic Nerve Injury Related to Hip Replacement Surgery: Imaging Detection by MR Neurography Despite Susceptibility Artifacts |
title_full_unstemmed | Sciatic Nerve Injury Related to Hip Replacement Surgery: Imaging Detection by MR Neurography Despite Susceptibility Artifacts |
title_short | Sciatic Nerve Injury Related to Hip Replacement Surgery: Imaging Detection by MR Neurography Despite Susceptibility Artifacts |
title_sort | sciatic nerve injury related to hip replacement surgery: imaging detection by mr neurography despite susceptibility artifacts |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3928432/ https://www.ncbi.nlm.nih.gov/pubmed/24558483 http://dx.doi.org/10.1371/journal.pone.0089154 |
work_keys_str_mv | AT wolfmarcel sciaticnerveinjuryrelatedtohipreplacementsurgeryimagingdetectionbymrneurographydespitesusceptibilityartifacts AT baumerphilipp sciaticnerveinjuryrelatedtohipreplacementsurgeryimagingdetectionbymrneurographydespitesusceptibilityartifacts AT pedromaria sciaticnerveinjuryrelatedtohipreplacementsurgeryimagingdetectionbymrneurographydespitesusceptibilityartifacts AT dombertthomas sciaticnerveinjuryrelatedtohipreplacementsurgeryimagingdetectionbymrneurographydespitesusceptibilityartifacts AT staubfrank sciaticnerveinjuryrelatedtohipreplacementsurgeryimagingdetectionbymrneurographydespitesusceptibilityartifacts AT heilandsabine sciaticnerveinjuryrelatedtohipreplacementsurgeryimagingdetectionbymrneurographydespitesusceptibilityartifacts AT bendszusmartin sciaticnerveinjuryrelatedtohipreplacementsurgeryimagingdetectionbymrneurographydespitesusceptibilityartifacts AT phammirko sciaticnerveinjuryrelatedtohipreplacementsurgeryimagingdetectionbymrneurographydespitesusceptibilityartifacts |