Cargando…

Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India

Computed tomography (CT) scanner under operating conditions has become a major source of human exposure to diagnostic X-rays. In this context, weighed CT dose index (CTDI(w)), volumetric CT dose index (CTDI(v)), and dose length product (DLP) are important parameter to assess procedures in CT imaging...

Descripción completa

Detalles Bibliográficos
Autores principales: Saravanakumar, A., Vaideki, K., Govindarajan, K. N., Jayakumar, S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3931229/
https://www.ncbi.nlm.nih.gov/pubmed/24600173
http://dx.doi.org/10.4103/0971-6203.125509
_version_ 1782304627821117440
author Saravanakumar, A.
Vaideki, K.
Govindarajan, K. N.
Jayakumar, S.
author_facet Saravanakumar, A.
Vaideki, K.
Govindarajan, K. N.
Jayakumar, S.
author_sort Saravanakumar, A.
collection PubMed
description Computed tomography (CT) scanner under operating conditions has become a major source of human exposure to diagnostic X-rays. In this context, weighed CT dose index (CTDI(w)), volumetric CT dose index (CTDI(v)), and dose length product (DLP) are important parameter to assess procedures in CT imaging as surrogate dose quantities for patient dose optimization. The current work aims to estimate the existing dose level of CT scanner for head, chest, and abdomen procedures in Pudhuchery in south India and establish dose reference level (DRL) for the region. The study was carried out for six CT scanners in six different radiology departments using 100 mm long pencil ionization chamber and polymethylmethacrylate (PMMA) phantom. From each CT scanner, data pertaining to patient and machine details were collected for 50 head, 50 chest, and 50 abdomen procedures performed over a period of 1 year. The experimental work was carried out using the machine operating parameters used during the procedures. Initially, dose received in the phantom at the center and periphery was measured by five point method. Using these values CTDI(w), CTDI(v), and DLP were calculated. The DRL is established based on the third quartile value of CTDI(v) and DLP which is 32 mGy and 925 mGy.cm for head, 12 mGy and 456 mGy.cm for chest, and 16 mGy and 482 mGy.cm for abdomen procedures. These values are well below European Commission Dose Reference Level (EC DRL) and comparable with the third quartile value reported for Tamil Nadu region in India. The present study is the first of its kind to determine the DRL for scanners operating in the Pudhuchery region. Similar studies in other regions of India are necessary in order to establish a National Dose Reference Level.
format Online
Article
Text
id pubmed-3931229
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-39312292014-03-05 Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India Saravanakumar, A. Vaideki, K. Govindarajan, K. N. Jayakumar, S. J Med Phys Technical Note Computed tomography (CT) scanner under operating conditions has become a major source of human exposure to diagnostic X-rays. In this context, weighed CT dose index (CTDI(w)), volumetric CT dose index (CTDI(v)), and dose length product (DLP) are important parameter to assess procedures in CT imaging as surrogate dose quantities for patient dose optimization. The current work aims to estimate the existing dose level of CT scanner for head, chest, and abdomen procedures in Pudhuchery in south India and establish dose reference level (DRL) for the region. The study was carried out for six CT scanners in six different radiology departments using 100 mm long pencil ionization chamber and polymethylmethacrylate (PMMA) phantom. From each CT scanner, data pertaining to patient and machine details were collected for 50 head, 50 chest, and 50 abdomen procedures performed over a period of 1 year. The experimental work was carried out using the machine operating parameters used during the procedures. Initially, dose received in the phantom at the center and periphery was measured by five point method. Using these values CTDI(w), CTDI(v), and DLP were calculated. The DRL is established based on the third quartile value of CTDI(v) and DLP which is 32 mGy and 925 mGy.cm for head, 12 mGy and 456 mGy.cm for chest, and 16 mGy and 482 mGy.cm for abdomen procedures. These values are well below European Commission Dose Reference Level (EC DRL) and comparable with the third quartile value reported for Tamil Nadu region in India. The present study is the first of its kind to determine the DRL for scanners operating in the Pudhuchery region. Similar studies in other regions of India are necessary in order to establish a National Dose Reference Level. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC3931229/ /pubmed/24600173 http://dx.doi.org/10.4103/0971-6203.125509 Text en Copyright: © Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Note
Saravanakumar, A.
Vaideki, K.
Govindarajan, K. N.
Jayakumar, S.
Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India
title Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India
title_full Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India
title_fullStr Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India
title_full_unstemmed Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India
title_short Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India
title_sort establishment of diagnostic reference levels in computed tomography for select procedures in pudhuchery, india
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3931229/
https://www.ncbi.nlm.nih.gov/pubmed/24600173
http://dx.doi.org/10.4103/0971-6203.125509
work_keys_str_mv AT saravanakumara establishmentofdiagnosticreferencelevelsincomputedtomographyforselectproceduresinpudhucheryindia
AT vaidekik establishmentofdiagnosticreferencelevelsincomputedtomographyforselectproceduresinpudhucheryindia
AT govindarajankn establishmentofdiagnosticreferencelevelsincomputedtomographyforselectproceduresinpudhucheryindia
AT jayakumars establishmentofdiagnosticreferencelevelsincomputedtomographyforselectproceduresinpudhucheryindia