Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study
Rationale: Cone Beam Computed Tomography imaging has become increasingly important in many fields of interventional therapies. Objective: Lung navigation study which is an uncommon soft tissue approach. Methods: As no effective organ radiation dose levels were available for this kind of Cone Beam Co...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Ivyspring International Publisher
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3931267/ https://www.ncbi.nlm.nih.gov/pubmed/24563674 http://dx.doi.org/10.7150/jca.8395 |
_version_ | 1782304633987792896 |
---|---|
author | Hohenforst-Schmidt, Wolfgang Banckwitz, Rosemarie Zarogoulidis, Paul Vogl, Thomas Darwiche, Kaid Goldberg, Eugene Huang, Haidong Simoff, Michael Li, Qiang Browning, Robert Freitag, Lutz Turner, J Francis Pivert, Patrick Le Yarmus, Lonny Zarogoulidis, Konstantinos Brachmann, Johannes |
author_facet | Hohenforst-Schmidt, Wolfgang Banckwitz, Rosemarie Zarogoulidis, Paul Vogl, Thomas Darwiche, Kaid Goldberg, Eugene Huang, Haidong Simoff, Michael Li, Qiang Browning, Robert Freitag, Lutz Turner, J Francis Pivert, Patrick Le Yarmus, Lonny Zarogoulidis, Konstantinos Brachmann, Johannes |
author_sort | Hohenforst-Schmidt, Wolfgang |
collection | PubMed |
description | Rationale: Cone Beam Computed Tomography imaging has become increasingly important in many fields of interventional therapies. Objective: Lung navigation study which is an uncommon soft tissue approach. Methods: As no effective organ radiation dose levels were available for this kind of Cone Beam Computed Tomography application we simulated in our DynaCT (Siemens AG, Forchheim, Germany) suite 2 measurements including 3D acquisition and again for 3D acquisition and 4 endobronchial navigation maneuvers under fluoroscopy towards a nodule after the 8(th) segmentation in the right upper lobe over a total period of 20 minutes (min). These figures reflect the average complexity and time in our experience. We hereby describe the first time the exact protocol of lung navigation by a Cone Beam Computed Tomography approach. Measurement: The hereby first time measured body radiation doses in that approach showed very promising numbers between 0,98-1,15mSv giving specific lung radiation doses of 0,42-0,38 mSv. Main results: These figures are comparable or even better to other lung navigation systems. Cone Beam Computed Tomography offers some unique features for lung interventionists as a realtime 1-step navigation system in an open structure feasible for endobronchial and transcutaneous approach. Conclusions: Due to this low level of radiation exposure Cone Beam Computed Tomography is expected to attract interventionists interested in using and guiding endobronchial or transcutaneous ablative procedures to peripheral endobronchial and other lung lesions. |
format | Online Article Text |
id | pubmed-3931267 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Ivyspring International Publisher |
record_format | MEDLINE/PubMed |
spelling | pubmed-39312672014-02-21 Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study Hohenforst-Schmidt, Wolfgang Banckwitz, Rosemarie Zarogoulidis, Paul Vogl, Thomas Darwiche, Kaid Goldberg, Eugene Huang, Haidong Simoff, Michael Li, Qiang Browning, Robert Freitag, Lutz Turner, J Francis Pivert, Patrick Le Yarmus, Lonny Zarogoulidis, Konstantinos Brachmann, Johannes J Cancer Research Paper Rationale: Cone Beam Computed Tomography imaging has become increasingly important in many fields of interventional therapies. Objective: Lung navigation study which is an uncommon soft tissue approach. Methods: As no effective organ radiation dose levels were available for this kind of Cone Beam Computed Tomography application we simulated in our DynaCT (Siemens AG, Forchheim, Germany) suite 2 measurements including 3D acquisition and again for 3D acquisition and 4 endobronchial navigation maneuvers under fluoroscopy towards a nodule after the 8(th) segmentation in the right upper lobe over a total period of 20 minutes (min). These figures reflect the average complexity and time in our experience. We hereby describe the first time the exact protocol of lung navigation by a Cone Beam Computed Tomography approach. Measurement: The hereby first time measured body radiation doses in that approach showed very promising numbers between 0,98-1,15mSv giving specific lung radiation doses of 0,42-0,38 mSv. Main results: These figures are comparable or even better to other lung navigation systems. Cone Beam Computed Tomography offers some unique features for lung interventionists as a realtime 1-step navigation system in an open structure feasible for endobronchial and transcutaneous approach. Conclusions: Due to this low level of radiation exposure Cone Beam Computed Tomography is expected to attract interventionists interested in using and guiding endobronchial or transcutaneous ablative procedures to peripheral endobronchial and other lung lesions. Ivyspring International Publisher 2014-02-06 /pmc/articles/PMC3931267/ /pubmed/24563674 http://dx.doi.org/10.7150/jca.8395 Text en © Ivyspring International Publisher. This is an open-access article distributed under the terms of the Creative Commons License (http://creativecommons.org/licenses/by-nc-nd/3.0/). Reproduction is permitted for personal, noncommercial use, provided that the article is in whole, unmodified, and properly cited. |
spellingShingle | Research Paper Hohenforst-Schmidt, Wolfgang Banckwitz, Rosemarie Zarogoulidis, Paul Vogl, Thomas Darwiche, Kaid Goldberg, Eugene Huang, Haidong Simoff, Michael Li, Qiang Browning, Robert Freitag, Lutz Turner, J Francis Pivert, Patrick Le Yarmus, Lonny Zarogoulidis, Konstantinos Brachmann, Johannes Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study |
title | Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study |
title_full | Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study |
title_fullStr | Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study |
title_full_unstemmed | Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study |
title_short | Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study |
title_sort | radiation exposure of patients by cone beam ct during endobronchial navigation - a phantom study |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3931267/ https://www.ncbi.nlm.nih.gov/pubmed/24563674 http://dx.doi.org/10.7150/jca.8395 |
work_keys_str_mv | AT hohenforstschmidtwolfgang radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy AT banckwitzrosemarie radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy AT zarogoulidispaul radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy AT voglthomas radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy AT darwichekaid radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy AT goldbergeugene radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy AT huanghaidong radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy AT simoffmichael radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy AT liqiang radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy AT browningrobert radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy AT freitaglutz radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy AT turnerjfrancis radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy AT pivertpatrickle radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy AT yarmuslonny radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy AT zarogoulidiskonstantinos radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy AT brachmannjohannes radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy |