Cargando…

Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study

Rationale: Cone Beam Computed Tomography imaging has become increasingly important in many fields of interventional therapies. Objective: Lung navigation study which is an uncommon soft tissue approach. Methods: As no effective organ radiation dose levels were available for this kind of Cone Beam Co...

Descripción completa

Detalles Bibliográficos
Autores principales: Hohenforst-Schmidt, Wolfgang, Banckwitz, Rosemarie, Zarogoulidis, Paul, Vogl, Thomas, Darwiche, Kaid, Goldberg, Eugene, Huang, Haidong, Simoff, Michael, Li, Qiang, Browning, Robert, Freitag, Lutz, Turner, J Francis, Pivert, Patrick Le, Yarmus, Lonny, Zarogoulidis, Konstantinos, Brachmann, Johannes
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Ivyspring International Publisher 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3931267/
https://www.ncbi.nlm.nih.gov/pubmed/24563674
http://dx.doi.org/10.7150/jca.8395
_version_ 1782304633987792896
author Hohenforst-Schmidt, Wolfgang
Banckwitz, Rosemarie
Zarogoulidis, Paul
Vogl, Thomas
Darwiche, Kaid
Goldberg, Eugene
Huang, Haidong
Simoff, Michael
Li, Qiang
Browning, Robert
Freitag, Lutz
Turner, J Francis
Pivert, Patrick Le
Yarmus, Lonny
Zarogoulidis, Konstantinos
Brachmann, Johannes
author_facet Hohenforst-Schmidt, Wolfgang
Banckwitz, Rosemarie
Zarogoulidis, Paul
Vogl, Thomas
Darwiche, Kaid
Goldberg, Eugene
Huang, Haidong
Simoff, Michael
Li, Qiang
Browning, Robert
Freitag, Lutz
Turner, J Francis
Pivert, Patrick Le
Yarmus, Lonny
Zarogoulidis, Konstantinos
Brachmann, Johannes
author_sort Hohenforst-Schmidt, Wolfgang
collection PubMed
description Rationale: Cone Beam Computed Tomography imaging has become increasingly important in many fields of interventional therapies. Objective: Lung navigation study which is an uncommon soft tissue approach. Methods: As no effective organ radiation dose levels were available for this kind of Cone Beam Computed Tomography application we simulated in our DynaCT (Siemens AG, Forchheim, Germany) suite 2 measurements including 3D acquisition and again for 3D acquisition and 4 endobronchial navigation maneuvers under fluoroscopy towards a nodule after the 8(th) segmentation in the right upper lobe over a total period of 20 minutes (min). These figures reflect the average complexity and time in our experience. We hereby describe the first time the exact protocol of lung navigation by a Cone Beam Computed Tomography approach. Measurement: The hereby first time measured body radiation doses in that approach showed very promising numbers between 0,98-1,15mSv giving specific lung radiation doses of 0,42-0,38 mSv. Main results: These figures are comparable or even better to other lung navigation systems. Cone Beam Computed Tomography offers some unique features for lung interventionists as a realtime 1-step navigation system in an open structure feasible for endobronchial and transcutaneous approach. Conclusions: Due to this low level of radiation exposure Cone Beam Computed Tomography is expected to attract interventionists interested in using and guiding endobronchial or transcutaneous ablative procedures to peripheral endobronchial and other lung lesions.
format Online
Article
Text
id pubmed-3931267
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Ivyspring International Publisher
record_format MEDLINE/PubMed
spelling pubmed-39312672014-02-21 Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study Hohenforst-Schmidt, Wolfgang Banckwitz, Rosemarie Zarogoulidis, Paul Vogl, Thomas Darwiche, Kaid Goldberg, Eugene Huang, Haidong Simoff, Michael Li, Qiang Browning, Robert Freitag, Lutz Turner, J Francis Pivert, Patrick Le Yarmus, Lonny Zarogoulidis, Konstantinos Brachmann, Johannes J Cancer Research Paper Rationale: Cone Beam Computed Tomography imaging has become increasingly important in many fields of interventional therapies. Objective: Lung navigation study which is an uncommon soft tissue approach. Methods: As no effective organ radiation dose levels were available for this kind of Cone Beam Computed Tomography application we simulated in our DynaCT (Siemens AG, Forchheim, Germany) suite 2 measurements including 3D acquisition and again for 3D acquisition and 4 endobronchial navigation maneuvers under fluoroscopy towards a nodule after the 8(th) segmentation in the right upper lobe over a total period of 20 minutes (min). These figures reflect the average complexity and time in our experience. We hereby describe the first time the exact protocol of lung navigation by a Cone Beam Computed Tomography approach. Measurement: The hereby first time measured body radiation doses in that approach showed very promising numbers between 0,98-1,15mSv giving specific lung radiation doses of 0,42-0,38 mSv. Main results: These figures are comparable or even better to other lung navigation systems. Cone Beam Computed Tomography offers some unique features for lung interventionists as a realtime 1-step navigation system in an open structure feasible for endobronchial and transcutaneous approach. Conclusions: Due to this low level of radiation exposure Cone Beam Computed Tomography is expected to attract interventionists interested in using and guiding endobronchial or transcutaneous ablative procedures to peripheral endobronchial and other lung lesions. Ivyspring International Publisher 2014-02-06 /pmc/articles/PMC3931267/ /pubmed/24563674 http://dx.doi.org/10.7150/jca.8395 Text en © Ivyspring International Publisher. This is an open-access article distributed under the terms of the Creative Commons License (http://creativecommons.org/licenses/by-nc-nd/3.0/). Reproduction is permitted for personal, noncommercial use, provided that the article is in whole, unmodified, and properly cited.
spellingShingle Research Paper
Hohenforst-Schmidt, Wolfgang
Banckwitz, Rosemarie
Zarogoulidis, Paul
Vogl, Thomas
Darwiche, Kaid
Goldberg, Eugene
Huang, Haidong
Simoff, Michael
Li, Qiang
Browning, Robert
Freitag, Lutz
Turner, J Francis
Pivert, Patrick Le
Yarmus, Lonny
Zarogoulidis, Konstantinos
Brachmann, Johannes
Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study
title Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study
title_full Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study
title_fullStr Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study
title_full_unstemmed Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study
title_short Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study
title_sort radiation exposure of patients by cone beam ct during endobronchial navigation - a phantom study
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3931267/
https://www.ncbi.nlm.nih.gov/pubmed/24563674
http://dx.doi.org/10.7150/jca.8395
work_keys_str_mv AT hohenforstschmidtwolfgang radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy
AT banckwitzrosemarie radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy
AT zarogoulidispaul radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy
AT voglthomas radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy
AT darwichekaid radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy
AT goldbergeugene radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy
AT huanghaidong radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy
AT simoffmichael radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy
AT liqiang radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy
AT browningrobert radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy
AT freitaglutz radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy
AT turnerjfrancis radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy
AT pivertpatrickle radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy
AT yarmuslonny radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy
AT zarogoulidiskonstantinos radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy
AT brachmannjohannes radiationexposureofpatientsbyconebeamctduringendobronchialnavigationaphantomstudy