Cargando…

Evaluation of three rapid diagnostic tests for the detection of human infections with Plasmodium knowlesi

BACKGROUND: Plasmodium knowlesi, a malaria parasite of Southeast Asian macaques, infects humans and can cause fatal malaria. It is difficult to diagnose by microscopy because of morphological similarity to Plasmodium malariae. Nested PCR assay is the most accurate method to distinguish P. knowlesi f...

Descripción completa

Detalles Bibliográficos
Autores principales: Foster, Deshka, Cox-Singh, Janet, Mohamad, Dayang SA, Krishna, Sanjeev, Chin, Pek P, Singh, Balbir
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3931291/
https://www.ncbi.nlm.nih.gov/pubmed/24548805
http://dx.doi.org/10.1186/1475-2875-13-60
_version_ 1782304638456823808
author Foster, Deshka
Cox-Singh, Janet
Mohamad, Dayang SA
Krishna, Sanjeev
Chin, Pek P
Singh, Balbir
author_facet Foster, Deshka
Cox-Singh, Janet
Mohamad, Dayang SA
Krishna, Sanjeev
Chin, Pek P
Singh, Balbir
author_sort Foster, Deshka
collection PubMed
description BACKGROUND: Plasmodium knowlesi, a malaria parasite of Southeast Asian macaques, infects humans and can cause fatal malaria. It is difficult to diagnose by microscopy because of morphological similarity to Plasmodium malariae. Nested PCR assay is the most accurate method to distinguish P. knowlesi from other Plasmodium species but is not cost effective in resource-poor settings. Rapid diagnostic tests (RDTs) are recommended for settings where malaria is prevalent. In this study, the effectiveness of three RDTs in detecting P. knowlesi from fresh and frozen patient blood samples was evaluated. METHODS: Forty malaria patients (28 P. knowlesi, ten P. vivax and two P. falciparum) diagnosed by microscopy were recruited in Sarawak, Malaysian Borneo during a 16-month period. Patient blood samples were used to determine parasitaemia by microscopy, confirm the Plasmodium species present by PCR and evaluate three RDTs: OptiMAL-IT, BinaxNOW® Malaria and Paramax-3. The RDTs were also evaluated using frozen blood samples from 41 knowlesi malaria patients. RESULTS: OptiMAL-IT was the most sensitive RDT, with a sensitivity of 71% (20/28; 95% CI = 54-88%) for fresh and 73% (30/41; 95% CI = 59-87%) for frozen knowlesi samples. However, it yielded predominantly falciparum-positive results due to cross-reactivity of the P. falciparum test reagent with P. knowlesi. BinaxNOW® Malaria correctly detected non-P. falciparum malaria in P. knowlesi samples but was the least sensitive, detecting only 29% (8/28; 95% CI = 12-46%) of fresh and 24% (10/41; 95% CI = 11-37%) of frozen samples. The Paramax-3 RDT tested positive for P. vivax with PCR-confirmed P. knowlesi samples with sensitivities of 40% (10/25; 95% CI = 21-59%) with fresh and 32% (13/41; 95% CI = 17-46%) with frozen samples. All RDTs correctly identified P. falciparum- and P. vivax-positive controls with parasitaemias above 2,000 parasites/μl blood. CONCLUSIONS: The RDTs detected Plasmodium in P. knowlesi-infected blood samples with poor sensitivity and specificity. Patients with P. knowlesi could be misdiagnosed as P. falciparum with OptiMAL-IT, P. vivax with Paramax-3 and more correctly as non-P. vivax/non-P. falciparum with BinaxNOW® Malaria. There is a need for a sensitive and specific RDT for malaria diagnosis in settings where P. knowlesi infections predominate.
format Online
Article
Text
id pubmed-3931291
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-39312912014-02-22 Evaluation of three rapid diagnostic tests for the detection of human infections with Plasmodium knowlesi Foster, Deshka Cox-Singh, Janet Mohamad, Dayang SA Krishna, Sanjeev Chin, Pek P Singh, Balbir Malar J Research BACKGROUND: Plasmodium knowlesi, a malaria parasite of Southeast Asian macaques, infects humans and can cause fatal malaria. It is difficult to diagnose by microscopy because of morphological similarity to Plasmodium malariae. Nested PCR assay is the most accurate method to distinguish P. knowlesi from other Plasmodium species but is not cost effective in resource-poor settings. Rapid diagnostic tests (RDTs) are recommended for settings where malaria is prevalent. In this study, the effectiveness of three RDTs in detecting P. knowlesi from fresh and frozen patient blood samples was evaluated. METHODS: Forty malaria patients (28 P. knowlesi, ten P. vivax and two P. falciparum) diagnosed by microscopy were recruited in Sarawak, Malaysian Borneo during a 16-month period. Patient blood samples were used to determine parasitaemia by microscopy, confirm the Plasmodium species present by PCR and evaluate three RDTs: OptiMAL-IT, BinaxNOW® Malaria and Paramax-3. The RDTs were also evaluated using frozen blood samples from 41 knowlesi malaria patients. RESULTS: OptiMAL-IT was the most sensitive RDT, with a sensitivity of 71% (20/28; 95% CI = 54-88%) for fresh and 73% (30/41; 95% CI = 59-87%) for frozen knowlesi samples. However, it yielded predominantly falciparum-positive results due to cross-reactivity of the P. falciparum test reagent with P. knowlesi. BinaxNOW® Malaria correctly detected non-P. falciparum malaria in P. knowlesi samples but was the least sensitive, detecting only 29% (8/28; 95% CI = 12-46%) of fresh and 24% (10/41; 95% CI = 11-37%) of frozen samples. The Paramax-3 RDT tested positive for P. vivax with PCR-confirmed P. knowlesi samples with sensitivities of 40% (10/25; 95% CI = 21-59%) with fresh and 32% (13/41; 95% CI = 17-46%) with frozen samples. All RDTs correctly identified P. falciparum- and P. vivax-positive controls with parasitaemias above 2,000 parasites/μl blood. CONCLUSIONS: The RDTs detected Plasmodium in P. knowlesi-infected blood samples with poor sensitivity and specificity. Patients with P. knowlesi could be misdiagnosed as P. falciparum with OptiMAL-IT, P. vivax with Paramax-3 and more correctly as non-P. vivax/non-P. falciparum with BinaxNOW® Malaria. There is a need for a sensitive and specific RDT for malaria diagnosis in settings where P. knowlesi infections predominate. BioMed Central 2014-02-18 /pmc/articles/PMC3931291/ /pubmed/24548805 http://dx.doi.org/10.1186/1475-2875-13-60 Text en Copyright © 2014 Foster et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Foster, Deshka
Cox-Singh, Janet
Mohamad, Dayang SA
Krishna, Sanjeev
Chin, Pek P
Singh, Balbir
Evaluation of three rapid diagnostic tests for the detection of human infections with Plasmodium knowlesi
title Evaluation of three rapid diagnostic tests for the detection of human infections with Plasmodium knowlesi
title_full Evaluation of three rapid diagnostic tests for the detection of human infections with Plasmodium knowlesi
title_fullStr Evaluation of three rapid diagnostic tests for the detection of human infections with Plasmodium knowlesi
title_full_unstemmed Evaluation of three rapid diagnostic tests for the detection of human infections with Plasmodium knowlesi
title_short Evaluation of three rapid diagnostic tests for the detection of human infections with Plasmodium knowlesi
title_sort evaluation of three rapid diagnostic tests for the detection of human infections with plasmodium knowlesi
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3931291/
https://www.ncbi.nlm.nih.gov/pubmed/24548805
http://dx.doi.org/10.1186/1475-2875-13-60
work_keys_str_mv AT fosterdeshka evaluationofthreerapiddiagnostictestsforthedetectionofhumaninfectionswithplasmodiumknowlesi
AT coxsinghjanet evaluationofthreerapiddiagnostictestsforthedetectionofhumaninfectionswithplasmodiumknowlesi
AT mohamaddayangsa evaluationofthreerapiddiagnostictestsforthedetectionofhumaninfectionswithplasmodiumknowlesi
AT krishnasanjeev evaluationofthreerapiddiagnostictestsforthedetectionofhumaninfectionswithplasmodiumknowlesi
AT chinpekp evaluationofthreerapiddiagnostictestsforthedetectionofhumaninfectionswithplasmodiumknowlesi
AT singhbalbir evaluationofthreerapiddiagnostictestsforthedetectionofhumaninfectionswithplasmodiumknowlesi