Cargando…
Inspiratory Flows and Volumes in Subjects with Non-CF Bronchiectasis Using a New Dry Powder Inhaler Device
INTRODUCTION: Drug inhalation via a dry-powder inhaler (DPI) is a convenient, time efficient alternative to nebulizers in the treatment of cystic fibrosis (CF) or non-CF bronchiectasis. Efficient drug administration via DPIs depends on the device resistance and adequate (≥45L/min) inspiratory flows...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bentham Open
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3933772/ https://www.ncbi.nlm.nih.gov/pubmed/24570764 http://dx.doi.org/10.2174/1874306401408010008 |
_version_ | 1782304989210738688 |
---|---|
author | Elkins, Mark R. Anderson, Sandra D. Perry, Clare P. Daviskas, Evangelia Charlton, Brett |
author_facet | Elkins, Mark R. Anderson, Sandra D. Perry, Clare P. Daviskas, Evangelia Charlton, Brett |
author_sort | Elkins, Mark R. |
collection | PubMed |
description | INTRODUCTION: Drug inhalation via a dry-powder inhaler (DPI) is a convenient, time efficient alternative to nebulizers in the treatment of cystic fibrosis (CF) or non-CF bronchiectasis. Efficient drug administration via DPIs depends on the device resistance and adequate (≥45L/min) inspiratory flows and volumes generated by individuals. Drypowder mannitol is delivered using a RS01 breath-actuated device developed by Plastiape, for Pharmaxis. The study aim was to determine in vivo if non-CF bronchiectasis patients’ inspiratory flows and volumes are adequate to use the RS01 DPI device. MATERIALS AND METHODOLOGY: An open, non-interventional study; enrolled 17 subjects with non-CF bronchiectasis, 18 to 80 years, with baseline FEV1 ≥1.0L and ≥50‰ predicted. Inspiratory flows and volumes were measured when subjects inhaled in a controlled manner through the RS01 device in series with a spirometer. RESULTS: The mean inspiratory volume (IV) of non-CF bronchiectasis subjects was 2.08 ± 0.5L and achieved a mean PIF of 78.6 ± 11.2L/min with the inhaler device. CONCLUSION: Use of the RS01 DPI device allowed adequate inspiratory flow and volume for dispersion of dry-powder mannitol in non-CF bronchiectasis patients. |
format | Online Article Text |
id | pubmed-3933772 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Bentham Open |
record_format | MEDLINE/PubMed |
spelling | pubmed-39337722014-02-25 Inspiratory Flows and Volumes in Subjects with Non-CF Bronchiectasis Using a New Dry Powder Inhaler Device Elkins, Mark R. Anderson, Sandra D. Perry, Clare P. Daviskas, Evangelia Charlton, Brett Open Respir Med J Article INTRODUCTION: Drug inhalation via a dry-powder inhaler (DPI) is a convenient, time efficient alternative to nebulizers in the treatment of cystic fibrosis (CF) or non-CF bronchiectasis. Efficient drug administration via DPIs depends on the device resistance and adequate (≥45L/min) inspiratory flows and volumes generated by individuals. Drypowder mannitol is delivered using a RS01 breath-actuated device developed by Plastiape, for Pharmaxis. The study aim was to determine in vivo if non-CF bronchiectasis patients’ inspiratory flows and volumes are adequate to use the RS01 DPI device. MATERIALS AND METHODOLOGY: An open, non-interventional study; enrolled 17 subjects with non-CF bronchiectasis, 18 to 80 years, with baseline FEV1 ≥1.0L and ≥50‰ predicted. Inspiratory flows and volumes were measured when subjects inhaled in a controlled manner through the RS01 device in series with a spirometer. RESULTS: The mean inspiratory volume (IV) of non-CF bronchiectasis subjects was 2.08 ± 0.5L and achieved a mean PIF of 78.6 ± 11.2L/min with the inhaler device. CONCLUSION: Use of the RS01 DPI device allowed adequate inspiratory flow and volume for dispersion of dry-powder mannitol in non-CF bronchiectasis patients. Bentham Open 2014-01-24 /pmc/articles/PMC3933772/ /pubmed/24570764 http://dx.doi.org/10.2174/1874306401408010008 Text en © Elkins et al.; Licensee Bentham Open. http://creativecommons.org/licenses/by-nc/3.0/ This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited. |
spellingShingle | Article Elkins, Mark R. Anderson, Sandra D. Perry, Clare P. Daviskas, Evangelia Charlton, Brett Inspiratory Flows and Volumes in Subjects with Non-CF Bronchiectasis Using a New Dry Powder Inhaler Device |
title | Inspiratory Flows and Volumes in Subjects with Non-CF Bronchiectasis Using a New Dry Powder Inhaler Device |
title_full | Inspiratory Flows and Volumes in Subjects with Non-CF Bronchiectasis Using a New Dry Powder Inhaler Device |
title_fullStr | Inspiratory Flows and Volumes in Subjects with Non-CF Bronchiectasis Using a New Dry Powder Inhaler Device |
title_full_unstemmed | Inspiratory Flows and Volumes in Subjects with Non-CF Bronchiectasis Using a New Dry Powder Inhaler Device |
title_short | Inspiratory Flows and Volumes in Subjects with Non-CF Bronchiectasis Using a New Dry Powder Inhaler Device |
title_sort | inspiratory flows and volumes in subjects with non-cf bronchiectasis using a new dry powder inhaler device |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3933772/ https://www.ncbi.nlm.nih.gov/pubmed/24570764 http://dx.doi.org/10.2174/1874306401408010008 |
work_keys_str_mv | AT elkinsmarkr inspiratoryflowsandvolumesinsubjectswithnoncfbronchiectasisusinganewdrypowderinhalerdevice AT andersonsandrad inspiratoryflowsandvolumesinsubjectswithnoncfbronchiectasisusinganewdrypowderinhalerdevice AT perryclarep inspiratoryflowsandvolumesinsubjectswithnoncfbronchiectasisusinganewdrypowderinhalerdevice AT daviskasevangelia inspiratoryflowsandvolumesinsubjectswithnoncfbronchiectasisusinganewdrypowderinhalerdevice AT charltonbrett inspiratoryflowsandvolumesinsubjectswithnoncfbronchiectasisusinganewdrypowderinhalerdevice |