Cargando…
Reproducibility of Magnetic Resonance Perfusion Imaging
Dynamic MR biomarkers (T2*-weighted or susceptibility-based and T1-weighted or relaxivity-enhanced) have been applied to assess tumor perfusion and its response to therapies. A significant challenge in the development of reliable biomarkers is a rigorous assessment and optimization of reproducibilit...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3934952/ https://www.ncbi.nlm.nih.gov/pubmed/24587040 http://dx.doi.org/10.1371/journal.pone.0089797 |
_version_ | 1782305130134110208 |
---|---|
author | Zhang, Xiaomeng Pagel, Mark D. Baker, Amanda F. Gillies, Robert J. |
author_facet | Zhang, Xiaomeng Pagel, Mark D. Baker, Amanda F. Gillies, Robert J. |
author_sort | Zhang, Xiaomeng |
collection | PubMed |
description | Dynamic MR biomarkers (T2*-weighted or susceptibility-based and T1-weighted or relaxivity-enhanced) have been applied to assess tumor perfusion and its response to therapies. A significant challenge in the development of reliable biomarkers is a rigorous assessment and optimization of reproducibility. The purpose of this study was to determine the measurement reproducibility of T1-weighted dynamic contrast-enhanced (DCE)-MRI and T2*-weighted dynamic susceptibility contrast (DSC)-MRI with two contrast agents (CA) of different molecular weight (MW): gadopentetate (Gd-DTPA, 0.5 kDa) and Gadomelitol (P792, 6.5 kDa). Each contrast agent was tested with eight mice that had subcutaneous MDA-MB-231 breast xenograft tumors. Each mouse was imaged with a combined DSC-DCE protocol three times within one week to achieve measures of reproducibility. DSC-MRI results were evaluated with a contrast to noise ratio (CNR) efficiency threshold. There was a clear signal drop (>95% probability threshold) in the DSC of normal tissue, while signal changes were minimal or non-existent (<95% probability threshold) in tumors. Mean within-subject coefficient of variation (wCV) of relative blood volume (rBV) in normal tissue was 11.78% for Gd-DTPA and 6.64% for P792. The intra-class correlation coefficient (ICC) of rBV in normal tissue was 0.940 for Gd-DTPA and 0.978 for P792. The inter-subject correlation coefficient was 0.092. Calculated K(trans) from DCE-MRI showed comparable reproducibility (mean wCV, 5.13% for Gd-DTPA, 8.06% for P792). ICC of K(trans) showed high intra-subject reproducibility (ICC = 0.999/0.995) and inter-subject heterogeneity (ICC = 0.774). Histograms of K(trans) distributions for three measurements had high degrees of overlap (sum of difference of the normalized histograms <0.01). These results represent homogeneous intra-subject measurement and heterogeneous inter-subject character of biological population, suggesting that perfusion MRI could be an imaging biomarker to monitor or predict response of disease. |
format | Online Article Text |
id | pubmed-3934952 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-39349522014-03-04 Reproducibility of Magnetic Resonance Perfusion Imaging Zhang, Xiaomeng Pagel, Mark D. Baker, Amanda F. Gillies, Robert J. PLoS One Research Article Dynamic MR biomarkers (T2*-weighted or susceptibility-based and T1-weighted or relaxivity-enhanced) have been applied to assess tumor perfusion and its response to therapies. A significant challenge in the development of reliable biomarkers is a rigorous assessment and optimization of reproducibility. The purpose of this study was to determine the measurement reproducibility of T1-weighted dynamic contrast-enhanced (DCE)-MRI and T2*-weighted dynamic susceptibility contrast (DSC)-MRI with two contrast agents (CA) of different molecular weight (MW): gadopentetate (Gd-DTPA, 0.5 kDa) and Gadomelitol (P792, 6.5 kDa). Each contrast agent was tested with eight mice that had subcutaneous MDA-MB-231 breast xenograft tumors. Each mouse was imaged with a combined DSC-DCE protocol three times within one week to achieve measures of reproducibility. DSC-MRI results were evaluated with a contrast to noise ratio (CNR) efficiency threshold. There was a clear signal drop (>95% probability threshold) in the DSC of normal tissue, while signal changes were minimal or non-existent (<95% probability threshold) in tumors. Mean within-subject coefficient of variation (wCV) of relative blood volume (rBV) in normal tissue was 11.78% for Gd-DTPA and 6.64% for P792. The intra-class correlation coefficient (ICC) of rBV in normal tissue was 0.940 for Gd-DTPA and 0.978 for P792. The inter-subject correlation coefficient was 0.092. Calculated K(trans) from DCE-MRI showed comparable reproducibility (mean wCV, 5.13% for Gd-DTPA, 8.06% for P792). ICC of K(trans) showed high intra-subject reproducibility (ICC = 0.999/0.995) and inter-subject heterogeneity (ICC = 0.774). Histograms of K(trans) distributions for three measurements had high degrees of overlap (sum of difference of the normalized histograms <0.01). These results represent homogeneous intra-subject measurement and heterogeneous inter-subject character of biological population, suggesting that perfusion MRI could be an imaging biomarker to monitor or predict response of disease. Public Library of Science 2014-02-25 /pmc/articles/PMC3934952/ /pubmed/24587040 http://dx.doi.org/10.1371/journal.pone.0089797 Text en © 2014 Zhang et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Zhang, Xiaomeng Pagel, Mark D. Baker, Amanda F. Gillies, Robert J. Reproducibility of Magnetic Resonance Perfusion Imaging |
title | Reproducibility of Magnetic Resonance Perfusion Imaging |
title_full | Reproducibility of Magnetic Resonance Perfusion Imaging |
title_fullStr | Reproducibility of Magnetic Resonance Perfusion Imaging |
title_full_unstemmed | Reproducibility of Magnetic Resonance Perfusion Imaging |
title_short | Reproducibility of Magnetic Resonance Perfusion Imaging |
title_sort | reproducibility of magnetic resonance perfusion imaging |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3934952/ https://www.ncbi.nlm.nih.gov/pubmed/24587040 http://dx.doi.org/10.1371/journal.pone.0089797 |
work_keys_str_mv | AT zhangxiaomeng reproducibilityofmagneticresonanceperfusionimaging AT pagelmarkd reproducibilityofmagneticresonanceperfusionimaging AT bakeramandaf reproducibilityofmagneticresonanceperfusionimaging AT gilliesrobertj reproducibilityofmagneticresonanceperfusionimaging |