Cargando…

Commissuroplasty for the anterior commissure defect caused by tricuspid valve endocarditis using patch closure and modified placement of a rigid ring

The anterior commissure defect of tricuspid valve may leave remnant regurgitation with inadequate leaflet coaptation after simple patch closure of the defect. A 19-year-old man underwent commissuroplasty for the anterior commissure defect caused by tricuspid valve endocarditis. Significant remnant r...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Jong Hun, Kim, Kyung Hwa, Choi, Jong Bum, Kuh, Ja Hong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3936927/
https://www.ncbi.nlm.nih.gov/pubmed/24552438
http://dx.doi.org/10.1186/1749-8090-9-36
_version_ 1782305392450076672
author Kim, Jong Hun
Kim, Kyung Hwa
Choi, Jong Bum
Kuh, Ja Hong
author_facet Kim, Jong Hun
Kim, Kyung Hwa
Choi, Jong Bum
Kuh, Ja Hong
author_sort Kim, Jong Hun
collection PubMed
description The anterior commissure defect of tricuspid valve may leave remnant regurgitation with inadequate leaflet coaptation after simple patch closure of the defect. A 19-year-old man underwent commissuroplasty for the anterior commissure defect caused by tricuspid valve endocarditis. Significant remnant regurgitation after patch closure of the anterior commissure defect was successfully solved by modified placement of an undersized rigid ring along the functional valve opening. The anterior horn of the rigid ring was affixed to the medial margin of the patch to reinforce the new commissure and enhance leaflet coaptation.
format Online
Article
Text
id pubmed-3936927
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-39369272014-02-28 Commissuroplasty for the anterior commissure defect caused by tricuspid valve endocarditis using patch closure and modified placement of a rigid ring Kim, Jong Hun Kim, Kyung Hwa Choi, Jong Bum Kuh, Ja Hong J Cardiothorac Surg Case Report The anterior commissure defect of tricuspid valve may leave remnant regurgitation with inadequate leaflet coaptation after simple patch closure of the defect. A 19-year-old man underwent commissuroplasty for the anterior commissure defect caused by tricuspid valve endocarditis. Significant remnant regurgitation after patch closure of the anterior commissure defect was successfully solved by modified placement of an undersized rigid ring along the functional valve opening. The anterior horn of the rigid ring was affixed to the medial margin of the patch to reinforce the new commissure and enhance leaflet coaptation. BioMed Central 2014-02-20 /pmc/articles/PMC3936927/ /pubmed/24552438 http://dx.doi.org/10.1186/1749-8090-9-36 Text en Copyright © 2014 Kim et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Case Report
Kim, Jong Hun
Kim, Kyung Hwa
Choi, Jong Bum
Kuh, Ja Hong
Commissuroplasty for the anterior commissure defect caused by tricuspid valve endocarditis using patch closure and modified placement of a rigid ring
title Commissuroplasty for the anterior commissure defect caused by tricuspid valve endocarditis using patch closure and modified placement of a rigid ring
title_full Commissuroplasty for the anterior commissure defect caused by tricuspid valve endocarditis using patch closure and modified placement of a rigid ring
title_fullStr Commissuroplasty for the anterior commissure defect caused by tricuspid valve endocarditis using patch closure and modified placement of a rigid ring
title_full_unstemmed Commissuroplasty for the anterior commissure defect caused by tricuspid valve endocarditis using patch closure and modified placement of a rigid ring
title_short Commissuroplasty for the anterior commissure defect caused by tricuspid valve endocarditis using patch closure and modified placement of a rigid ring
title_sort commissuroplasty for the anterior commissure defect caused by tricuspid valve endocarditis using patch closure and modified placement of a rigid ring
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3936927/
https://www.ncbi.nlm.nih.gov/pubmed/24552438
http://dx.doi.org/10.1186/1749-8090-9-36
work_keys_str_mv AT kimjonghun commissuroplastyfortheanteriorcommissuredefectcausedbytricuspidvalveendocarditisusingpatchclosureandmodifiedplacementofarigidring
AT kimkyunghwa commissuroplastyfortheanteriorcommissuredefectcausedbytricuspidvalveendocarditisusingpatchclosureandmodifiedplacementofarigidring
AT choijongbum commissuroplastyfortheanteriorcommissuredefectcausedbytricuspidvalveendocarditisusingpatchclosureandmodifiedplacementofarigidring
AT kuhjahong commissuroplastyfortheanteriorcommissuredefectcausedbytricuspidvalveendocarditisusingpatchclosureandmodifiedplacementofarigidring