Cargando…
Alterations in the endometrium of rats, rabbits, and Macaca mulatta that received an implantation of copper/low-density polyethylene nanocomposite
A copper/low-density polyethylene nanocomposite (nano-Cu/LDPE), a potential intrauterine device component material, has been developed from our research. A logical extension of our previous work, this study was conducted to investigate the expression of plasminogen activator inhibitor 1 (PAI-1), sub...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2014
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3940689/ https://www.ncbi.nlm.nih.gov/pubmed/24596465 http://dx.doi.org/10.2147/IJN.S56756 |
_version_ | 1782305806333509632 |
---|---|
author | Hu, Li-Xia Wang, Hong Rao, Meng Zhao, Xiao-Ling Yang, Jing Hu, Shi-Fu He, Jing Xia, Wei Liu, Hefang Zhen, Bo Di, Haihong Xie, Changsheng Xia, Xianping Zhu, Changhong |
author_facet | Hu, Li-Xia Wang, Hong Rao, Meng Zhao, Xiao-Ling Yang, Jing Hu, Shi-Fu He, Jing Xia, Wei Liu, Hefang Zhen, Bo Di, Haihong Xie, Changsheng Xia, Xianping Zhu, Changhong |
author_sort | Hu, Li-Xia |
collection | PubMed |
description | A copper/low-density polyethylene nanocomposite (nano-Cu/LDPE), a potential intrauterine device component material, has been developed from our research. A logical extension of our previous work, this study was conducted to investigate the expression of plasminogen activator inhibitor 1 (PAI-1), substance P (SP), and substance P receptor (SP-R) in the endometrium of Sprague Dawley rats, New Zealand White rabbits, and Macaca mulatta implanted with nano-Cu/LDPE composite. The influence of the nano-Cu/LDPE composite on the morphology of the endometrium was also investigated. Animals were randomly divided into five groups: the sham-operated control group (SO group), bulk copper group (Cu group), LDPE group, and nano-Cu/LDPE groups I and II. An expression of PAI-1, SP, and SP-R in the endometrial tissues was examined by immunohistochemistry at day 30, 60, 90, and 180 postimplantation. The significant difference for PAI-1, SP, and SP-R between the nano-Cu/LDPE groups and the SO group (P<0.05) was identified when the observation period was terminated, and the changes of nano-Cu/LDPE on these parameters were less remarkable than those of the Cu group (P<0.05). The damage to the endometrial morphology caused by the nano-Cu/LDPE composite was much less than that caused by bulk copper. The nano-Cu/LDPE composite might be a potential substitute for conventional materials for intrauterine devices in the future because of its decreased adverse effects on the endometrial microenvironment. |
format | Online Article Text |
id | pubmed-3940689 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-39406892014-03-04 Alterations in the endometrium of rats, rabbits, and Macaca mulatta that received an implantation of copper/low-density polyethylene nanocomposite Hu, Li-Xia Wang, Hong Rao, Meng Zhao, Xiao-Ling Yang, Jing Hu, Shi-Fu He, Jing Xia, Wei Liu, Hefang Zhen, Bo Di, Haihong Xie, Changsheng Xia, Xianping Zhu, Changhong Int J Nanomedicine A copper/low-density polyethylene nanocomposite (nano-Cu/LDPE), a potential intrauterine device component material, has been developed from our research. A logical extension of our previous work, this study was conducted to investigate the expression of plasminogen activator inhibitor 1 (PAI-1), substance P (SP), and substance P receptor (SP-R) in the endometrium of Sprague Dawley rats, New Zealand White rabbits, and Macaca mulatta implanted with nano-Cu/LDPE composite. The influence of the nano-Cu/LDPE composite on the morphology of the endometrium was also investigated. Animals were randomly divided into five groups: the sham-operated control group (SO group), bulk copper group (Cu group), LDPE group, and nano-Cu/LDPE groups I and II. An expression of PAI-1, SP, and SP-R in the endometrial tissues was examined by immunohistochemistry at day 30, 60, 90, and 180 postimplantation. The significant difference for PAI-1, SP, and SP-R between the nano-Cu/LDPE groups and the SO group (P<0.05) was identified when the observation period was terminated, and the changes of nano-Cu/LDPE on these parameters were less remarkable than those of the Cu group (P<0.05). The damage to the endometrial morphology caused by the nano-Cu/LDPE composite was much less than that caused by bulk copper. The nano-Cu/LDPE composite might be a potential substitute for conventional materials for intrauterine devices in the future because of its decreased adverse effects on the endometrial microenvironment. Dove Medical Press 2014-02-25 /pmc/articles/PMC3940689/ /pubmed/24596465 http://dx.doi.org/10.2147/IJN.S56756 Text en © 2014 Hu et al. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Hu, Li-Xia Wang, Hong Rao, Meng Zhao, Xiao-Ling Yang, Jing Hu, Shi-Fu He, Jing Xia, Wei Liu, Hefang Zhen, Bo Di, Haihong Xie, Changsheng Xia, Xianping Zhu, Changhong Alterations in the endometrium of rats, rabbits, and Macaca mulatta that received an implantation of copper/low-density polyethylene nanocomposite |
title | Alterations in the endometrium of rats, rabbits, and Macaca mulatta that received an implantation of copper/low-density polyethylene nanocomposite |
title_full | Alterations in the endometrium of rats, rabbits, and Macaca mulatta that received an implantation of copper/low-density polyethylene nanocomposite |
title_fullStr | Alterations in the endometrium of rats, rabbits, and Macaca mulatta that received an implantation of copper/low-density polyethylene nanocomposite |
title_full_unstemmed | Alterations in the endometrium of rats, rabbits, and Macaca mulatta that received an implantation of copper/low-density polyethylene nanocomposite |
title_short | Alterations in the endometrium of rats, rabbits, and Macaca mulatta that received an implantation of copper/low-density polyethylene nanocomposite |
title_sort | alterations in the endometrium of rats, rabbits, and macaca mulatta that received an implantation of copper/low-density polyethylene nanocomposite |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3940689/ https://www.ncbi.nlm.nih.gov/pubmed/24596465 http://dx.doi.org/10.2147/IJN.S56756 |
work_keys_str_mv | AT hulixia alterationsintheendometriumofratsrabbitsandmacacamulattathatreceivedanimplantationofcopperlowdensitypolyethylenenanocomposite AT wanghong alterationsintheendometriumofratsrabbitsandmacacamulattathatreceivedanimplantationofcopperlowdensitypolyethylenenanocomposite AT raomeng alterationsintheendometriumofratsrabbitsandmacacamulattathatreceivedanimplantationofcopperlowdensitypolyethylenenanocomposite AT zhaoxiaoling alterationsintheendometriumofratsrabbitsandmacacamulattathatreceivedanimplantationofcopperlowdensitypolyethylenenanocomposite AT yangjing alterationsintheendometriumofratsrabbitsandmacacamulattathatreceivedanimplantationofcopperlowdensitypolyethylenenanocomposite AT hushifu alterationsintheendometriumofratsrabbitsandmacacamulattathatreceivedanimplantationofcopperlowdensitypolyethylenenanocomposite AT hejing alterationsintheendometriumofratsrabbitsandmacacamulattathatreceivedanimplantationofcopperlowdensitypolyethylenenanocomposite AT xiawei alterationsintheendometriumofratsrabbitsandmacacamulattathatreceivedanimplantationofcopperlowdensitypolyethylenenanocomposite AT liuhefang alterationsintheendometriumofratsrabbitsandmacacamulattathatreceivedanimplantationofcopperlowdensitypolyethylenenanocomposite AT zhenbo alterationsintheendometriumofratsrabbitsandmacacamulattathatreceivedanimplantationofcopperlowdensitypolyethylenenanocomposite AT dihaihong alterationsintheendometriumofratsrabbitsandmacacamulattathatreceivedanimplantationofcopperlowdensitypolyethylenenanocomposite AT xiechangsheng alterationsintheendometriumofratsrabbitsandmacacamulattathatreceivedanimplantationofcopperlowdensitypolyethylenenanocomposite AT xiaxianping alterationsintheendometriumofratsrabbitsandmacacamulattathatreceivedanimplantationofcopperlowdensitypolyethylenenanocomposite AT zhuchanghong alterationsintheendometriumofratsrabbitsandmacacamulattathatreceivedanimplantationofcopperlowdensitypolyethylenenanocomposite |