Cargando…
A CT scan protocol for the detection of radiographic loosening of the glenoid component after total shoulder arthroplasty
BACKGROUND AND PURPOSE: It is difficult to evaluate glenoid component periprosthetic radiolucencies in total shoulder arthroplasties (TSAs) using plain radiographs. This study was performed to evaluate whether computed tomography (CT) using a specific patient position in the CT scanner provides a be...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Informa Healthcare
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3940998/ https://www.ncbi.nlm.nih.gov/pubmed/24286563 http://dx.doi.org/10.3109/17453674.2013.869653 |
_version_ | 1782305852744531968 |
---|---|
author | Gregory, Thomas Hansen, Ulrich Khanna, Monica Mutchler, Celine Urien, Saik Amis, Andrew A Augereau, Bernard Emery, Roger |
author_facet | Gregory, Thomas Hansen, Ulrich Khanna, Monica Mutchler, Celine Urien, Saik Amis, Andrew A Augereau, Bernard Emery, Roger |
author_sort | Gregory, Thomas |
collection | PubMed |
description | BACKGROUND AND PURPOSE: It is difficult to evaluate glenoid component periprosthetic radiolucencies in total shoulder arthroplasties (TSAs) using plain radiographs. This study was performed to evaluate whether computed tomography (CT) using a specific patient position in the CT scanner provides a better method for assessing radiolucencies in TSA. METHODS: Following TSA, 11 patients were CT scanned in a lateral decubitus position with maximum forward flexion, which aligns the glenoid orientation with the axis of the CT scanner. Follow-up CT scanning is part of our routine patient care. Glenoid component periprosthetic lucency was assessed according to the Molé score and it was compared to routine plain radiographs by 5 observers. RESULTS: The protocol almost completely eliminated metal artifacts in the CT images and allowed accurate assessment of periprosthetic lucency of the glenoid fixation. Positioning of the patient within the CT scanner as described was possible for all 11 patients. A radiolucent line was identified in 54 of the 55 observed CT scans and osteolysis was identified in 25 observations. The average radiolucent line Molé score was 3.4 (SD 2.7) points with plain radiographs and 9.5 (SD 0.8) points with CT scans (p = 0.001). The mean intra-observer variance was lower in the CT scan group than in the plain radiograph group (p = 0.001). INTERPRETATION: The CT scan protocol we used is of clinical value in routine assessment of glenoid periprosthetic lucency after TSA. The technique improves the ability to detect and monitor radiolucent lines and, therefore, possibly implant loosening also. |
format | Online Article Text |
id | pubmed-3940998 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Informa Healthcare |
record_format | MEDLINE/PubMed |
spelling | pubmed-39409982014-03-10 A CT scan protocol for the detection of radiographic loosening of the glenoid component after total shoulder arthroplasty Gregory, Thomas Hansen, Ulrich Khanna, Monica Mutchler, Celine Urien, Saik Amis, Andrew A Augereau, Bernard Emery, Roger Acta Orthop Spine, Shoulder and Hand BACKGROUND AND PURPOSE: It is difficult to evaluate glenoid component periprosthetic radiolucencies in total shoulder arthroplasties (TSAs) using plain radiographs. This study was performed to evaluate whether computed tomography (CT) using a specific patient position in the CT scanner provides a better method for assessing radiolucencies in TSA. METHODS: Following TSA, 11 patients were CT scanned in a lateral decubitus position with maximum forward flexion, which aligns the glenoid orientation with the axis of the CT scanner. Follow-up CT scanning is part of our routine patient care. Glenoid component periprosthetic lucency was assessed according to the Molé score and it was compared to routine plain radiographs by 5 observers. RESULTS: The protocol almost completely eliminated metal artifacts in the CT images and allowed accurate assessment of periprosthetic lucency of the glenoid fixation. Positioning of the patient within the CT scanner as described was possible for all 11 patients. A radiolucent line was identified in 54 of the 55 observed CT scans and osteolysis was identified in 25 observations. The average radiolucent line Molé score was 3.4 (SD 2.7) points with plain radiographs and 9.5 (SD 0.8) points with CT scans (p = 0.001). The mean intra-observer variance was lower in the CT scan group than in the plain radiograph group (p = 0.001). INTERPRETATION: The CT scan protocol we used is of clinical value in routine assessment of glenoid periprosthetic lucency after TSA. The technique improves the ability to detect and monitor radiolucent lines and, therefore, possibly implant loosening also. Informa Healthcare 2014-02 2014-02-25 /pmc/articles/PMC3940998/ /pubmed/24286563 http://dx.doi.org/10.3109/17453674.2013.869653 Text en Copyright: © Nordic Orthopaedic Federation http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited. |
spellingShingle | Spine, Shoulder and Hand Gregory, Thomas Hansen, Ulrich Khanna, Monica Mutchler, Celine Urien, Saik Amis, Andrew A Augereau, Bernard Emery, Roger A CT scan protocol for the detection of radiographic loosening of the glenoid component after total shoulder arthroplasty |
title | A CT scan protocol for the detection of radiographic loosening of the glenoid component after total shoulder arthroplasty |
title_full | A CT scan protocol for the detection of radiographic loosening of the glenoid component after total shoulder arthroplasty |
title_fullStr | A CT scan protocol for the detection of radiographic loosening of the glenoid component after total shoulder arthroplasty |
title_full_unstemmed | A CT scan protocol for the detection of radiographic loosening of the glenoid component after total shoulder arthroplasty |
title_short | A CT scan protocol for the detection of radiographic loosening of the glenoid component after total shoulder arthroplasty |
title_sort | ct scan protocol for the detection of radiographic loosening of the glenoid component after total shoulder arthroplasty |
topic | Spine, Shoulder and Hand |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3940998/ https://www.ncbi.nlm.nih.gov/pubmed/24286563 http://dx.doi.org/10.3109/17453674.2013.869653 |
work_keys_str_mv | AT gregorythomas actscanprotocolforthedetectionofradiographiclooseningoftheglenoidcomponentaftertotalshoulderarthroplasty AT hansenulrich actscanprotocolforthedetectionofradiographiclooseningoftheglenoidcomponentaftertotalshoulderarthroplasty AT khannamonica actscanprotocolforthedetectionofradiographiclooseningoftheglenoidcomponentaftertotalshoulderarthroplasty AT mutchlerceline actscanprotocolforthedetectionofradiographiclooseningoftheglenoidcomponentaftertotalshoulderarthroplasty AT uriensaik actscanprotocolforthedetectionofradiographiclooseningoftheglenoidcomponentaftertotalshoulderarthroplasty AT amisandrewa actscanprotocolforthedetectionofradiographiclooseningoftheglenoidcomponentaftertotalshoulderarthroplasty AT augereaubernard actscanprotocolforthedetectionofradiographiclooseningoftheglenoidcomponentaftertotalshoulderarthroplasty AT emeryroger actscanprotocolforthedetectionofradiographiclooseningoftheglenoidcomponentaftertotalshoulderarthroplasty AT gregorythomas ctscanprotocolforthedetectionofradiographiclooseningoftheglenoidcomponentaftertotalshoulderarthroplasty AT hansenulrich ctscanprotocolforthedetectionofradiographiclooseningoftheglenoidcomponentaftertotalshoulderarthroplasty AT khannamonica ctscanprotocolforthedetectionofradiographiclooseningoftheglenoidcomponentaftertotalshoulderarthroplasty AT mutchlerceline ctscanprotocolforthedetectionofradiographiclooseningoftheglenoidcomponentaftertotalshoulderarthroplasty AT uriensaik ctscanprotocolforthedetectionofradiographiclooseningoftheglenoidcomponentaftertotalshoulderarthroplasty AT amisandrewa ctscanprotocolforthedetectionofradiographiclooseningoftheglenoidcomponentaftertotalshoulderarthroplasty AT augereaubernard ctscanprotocolforthedetectionofradiographiclooseningoftheglenoidcomponentaftertotalshoulderarthroplasty AT emeryroger ctscanprotocolforthedetectionofradiographiclooseningoftheglenoidcomponentaftertotalshoulderarthroplasty |