Cargando…
Technical Report of Free Hand Pedicle Screw Placement using the Entry Points with Junction of Proximal Edge of Transverse Process and Lamina in Lumbar Spine: Analysis of 2601 Consecutive Screws
OBJECTIVE: A variety of different pedicle screws entry point techniques are used for the lumbar pedicle screws placement. This study reported Kim's entry point of lumbar pedicle screws with free hand technique and the accuracy of this technique. METHODS: We retrospectively reviewed the 584 case...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Spinal Neurosurgery Society
2013
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3941737/ https://www.ncbi.nlm.nih.gov/pubmed/24757450 http://dx.doi.org/10.14245/kjs.2013.10.1.7 |
_version_ | 1782305967220719616 |
---|---|
author | Oh, Chang Hyun Yoon, Seung Hwan Kim, Yongjung J. Hyun, Dongkeun Park, Hyeong-Chun |
author_facet | Oh, Chang Hyun Yoon, Seung Hwan Kim, Yongjung J. Hyun, Dongkeun Park, Hyeong-Chun |
author_sort | Oh, Chang Hyun |
collection | PubMed |
description | OBJECTIVE: A variety of different pedicle screws entry point techniques are used for the lumbar pedicle screws placement. This study reported Kim's entry point of lumbar pedicle screws with free hand technique and the accuracy of this technique. METHODS: We retrospectively reviewed the 584 cases with free hand placed lumbar pedicle screw placement. The diagnosis included 491 cases with degenerative spine, 59 cases with trauma, 29 cases with metastatic disease, and 5 cases with scoliosis. A total of 2601 lumbar pedicle screws were placed, and the entry points of lumbar pedicle screws were the junction of proximal edge of transverse process and lamina. Incidence and extent of cortical breach by misplaced pedicle screw was determined by review of intra-operative and post-operative radiographs and/or computed tomography. RESULTS: Among the total 2601 lumbar free hand placed pedicle screws, 114 screws (4.4%) in 79 patients (13.5%) were repositioned screws with suspected screw malposition during operation, and 37 screws (1.4%) in 31 patients (5.3%) were identified as moderate to severe breaching the pedicle after post-operative imaging studies. Among the patient with malpositioned screws, 3 patients showed nerve irritation sign of the lesion, and 2 cases were symptom improved after nerve block and conservative management, and 1 case was removed the screw after the failure of the treatment. CONCLUSION: Free hand pedicle screw placement based on external landmark with the junction of proximal edge of transverse process and lamina showed acceptable safety and accuracy and avoidance of radiation exposure. |
format | Online Article Text |
id | pubmed-3941737 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | The Korean Spinal Neurosurgery Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-39417372014-04-22 Technical Report of Free Hand Pedicle Screw Placement using the Entry Points with Junction of Proximal Edge of Transverse Process and Lamina in Lumbar Spine: Analysis of 2601 Consecutive Screws Oh, Chang Hyun Yoon, Seung Hwan Kim, Yongjung J. Hyun, Dongkeun Park, Hyeong-Chun Korean J Spine OBJECTIVE: A variety of different pedicle screws entry point techniques are used for the lumbar pedicle screws placement. This study reported Kim's entry point of lumbar pedicle screws with free hand technique and the accuracy of this technique. METHODS: We retrospectively reviewed the 584 cases with free hand placed lumbar pedicle screw placement. The diagnosis included 491 cases with degenerative spine, 59 cases with trauma, 29 cases with metastatic disease, and 5 cases with scoliosis. A total of 2601 lumbar pedicle screws were placed, and the entry points of lumbar pedicle screws were the junction of proximal edge of transverse process and lamina. Incidence and extent of cortical breach by misplaced pedicle screw was determined by review of intra-operative and post-operative radiographs and/or computed tomography. RESULTS: Among the total 2601 lumbar free hand placed pedicle screws, 114 screws (4.4%) in 79 patients (13.5%) were repositioned screws with suspected screw malposition during operation, and 37 screws (1.4%) in 31 patients (5.3%) were identified as moderate to severe breaching the pedicle after post-operative imaging studies. Among the patient with malpositioned screws, 3 patients showed nerve irritation sign of the lesion, and 2 cases were symptom improved after nerve block and conservative management, and 1 case was removed the screw after the failure of the treatment. CONCLUSION: Free hand pedicle screw placement based on external landmark with the junction of proximal edge of transverse process and lamina showed acceptable safety and accuracy and avoidance of radiation exposure. The Korean Spinal Neurosurgery Society 2013-03 2013-03-31 /pmc/articles/PMC3941737/ /pubmed/24757450 http://dx.doi.org/10.14245/kjs.2013.10.1.7 Text en Copyright © 2013 The Korean Spinal Neurosurgery Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Oh, Chang Hyun Yoon, Seung Hwan Kim, Yongjung J. Hyun, Dongkeun Park, Hyeong-Chun Technical Report of Free Hand Pedicle Screw Placement using the Entry Points with Junction of Proximal Edge of Transverse Process and Lamina in Lumbar Spine: Analysis of 2601 Consecutive Screws |
title | Technical Report of Free Hand Pedicle Screw Placement using the Entry Points with Junction of Proximal Edge of Transverse Process and Lamina in Lumbar Spine: Analysis of 2601 Consecutive Screws |
title_full | Technical Report of Free Hand Pedicle Screw Placement using the Entry Points with Junction of Proximal Edge of Transverse Process and Lamina in Lumbar Spine: Analysis of 2601 Consecutive Screws |
title_fullStr | Technical Report of Free Hand Pedicle Screw Placement using the Entry Points with Junction of Proximal Edge of Transverse Process and Lamina in Lumbar Spine: Analysis of 2601 Consecutive Screws |
title_full_unstemmed | Technical Report of Free Hand Pedicle Screw Placement using the Entry Points with Junction of Proximal Edge of Transverse Process and Lamina in Lumbar Spine: Analysis of 2601 Consecutive Screws |
title_short | Technical Report of Free Hand Pedicle Screw Placement using the Entry Points with Junction of Proximal Edge of Transverse Process and Lamina in Lumbar Spine: Analysis of 2601 Consecutive Screws |
title_sort | technical report of free hand pedicle screw placement using the entry points with junction of proximal edge of transverse process and lamina in lumbar spine: analysis of 2601 consecutive screws |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3941737/ https://www.ncbi.nlm.nih.gov/pubmed/24757450 http://dx.doi.org/10.14245/kjs.2013.10.1.7 |
work_keys_str_mv | AT ohchanghyun technicalreportoffreehandpediclescrewplacementusingtheentrypointswithjunctionofproximaledgeoftransverseprocessandlaminainlumbarspineanalysisof2601consecutivescrews AT yoonseunghwan technicalreportoffreehandpediclescrewplacementusingtheentrypointswithjunctionofproximaledgeoftransverseprocessandlaminainlumbarspineanalysisof2601consecutivescrews AT kimyongjungj technicalreportoffreehandpediclescrewplacementusingtheentrypointswithjunctionofproximaledgeoftransverseprocessandlaminainlumbarspineanalysisof2601consecutivescrews AT hyundongkeun technicalreportoffreehandpediclescrewplacementusingtheentrypointswithjunctionofproximaledgeoftransverseprocessandlaminainlumbarspineanalysisof2601consecutivescrews AT parkhyeongchun technicalreportoffreehandpediclescrewplacementusingtheentrypointswithjunctionofproximaledgeoftransverseprocessandlaminainlumbarspineanalysisof2601consecutivescrews |