Cargando…
Development and Validation of a High-Performance Liquid Chromatography Method With UV Detection for Determination of 1-(2-phenylethyl)-5- (quinaldin-4-yl) Biuret in Rat Plasma
BACKGROUND: Recently, biuret derivatives have been reported as showing moderate to good cytotoxic effect against certain cancer cell lines. In this study, a high-performance liquid chromatography method was developed for determination of 1-(2-phenylethyl)-5-(quinaldin-4-yl) biuret (PEQB) in rat plas...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
DocS
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3941904/ https://www.ncbi.nlm.nih.gov/pubmed/24624193 |
_version_ | 1782305996675219456 |
---|---|
author | Adibpour, Neda Ahmadnasr, Maryam Khodayar, Mohammad Javad Rezaee, Saeed |
author_facet | Adibpour, Neda Ahmadnasr, Maryam Khodayar, Mohammad Javad Rezaee, Saeed |
author_sort | Adibpour, Neda |
collection | PubMed |
description | BACKGROUND: Recently, biuret derivatives have been reported as showing moderate to good cytotoxic effect against certain cancer cell lines. In this study, a high-performance liquid chromatography method was developed for determination of 1-(2-phenylethyl)-5-(quinaldin-4-yl) biuret (PEQB) in rat plasma to use in future studies on this compound and related derivatives. OBJECTIVES: In this study, we describe a simple and sensitive high-performance liquid chromatography method with UV detection for determination of 1-(2-phenylethyl)-6-(quinaldin-4-yl) biuret (PEQB) in rat plasma. MATERIALS AND METHODS: Separations were performed on a Nucleosil-100 CN HPLC column (125 × 4.0 mm) (5 µm), using a mixture of acetonitrile: methanol: potassium dihydrogen phosphate buffer (0.05 M, pH 3.5) (10:10:80) as mobile phase delivered at a flow rate of 1 mL/minute. Detection of PEQB and internal standard (1-([[3-(1,3-benzothiazol-2-ylsulfanyl)propyl]carbamoyl]amino)-N-phenylformamide) was performed at 235 nm and ambient temperature. Plasma samples (200 µL) were prepared by addition of 40 µL internal standard (100 µg/mL), and 400 µL acetonitrile. After vortex mixing and centrifugation at 10000 g, 50 µL of the clear supernatant was directly injected onto the chromatography column. Calibration curves were constructed by fitting the peak area ratio of the biuret to internal standard against concentration of biuret to a power model using generalized least squares nonlinear regression method. RESULTS: Under the above chromatography condition, biuret compound (PEQB) and the internal standard were detected at 4.5 and 13.5 minutes, respectively. Limit of quantitation of the PEQB was 0.1 µg/mL. Accuracy of the method over the concentration range of 0.1-100 µg/mL was between 88-109%. Inter- and intraday precisions were 4-19% and 6-8%, respectively. A good relationship in the form of a power model was found for two separate concentration ranges of 0.1-1 and 2.5-100 µg/mL (R (2)> 0.99). CONCLUSIONS: The presented simple HPLC method is sufficiently accurate, precise and sensitive for the quantitation of 1-(2-phenylethyl)-5-(quinaldin-4-yl) biuret in rat plasma. |
format | Online Article Text |
id | pubmed-3941904 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | DocS |
record_format | MEDLINE/PubMed |
spelling | pubmed-39419042014-03-12 Development and Validation of a High-Performance Liquid Chromatography Method With UV Detection for Determination of 1-(2-phenylethyl)-5- (quinaldin-4-yl) Biuret in Rat Plasma Adibpour, Neda Ahmadnasr, Maryam Khodayar, Mohammad Javad Rezaee, Saeed Jundishapur J Nat Pharm Prod Research Article BACKGROUND: Recently, biuret derivatives have been reported as showing moderate to good cytotoxic effect against certain cancer cell lines. In this study, a high-performance liquid chromatography method was developed for determination of 1-(2-phenylethyl)-5-(quinaldin-4-yl) biuret (PEQB) in rat plasma to use in future studies on this compound and related derivatives. OBJECTIVES: In this study, we describe a simple and sensitive high-performance liquid chromatography method with UV detection for determination of 1-(2-phenylethyl)-6-(quinaldin-4-yl) biuret (PEQB) in rat plasma. MATERIALS AND METHODS: Separations were performed on a Nucleosil-100 CN HPLC column (125 × 4.0 mm) (5 µm), using a mixture of acetonitrile: methanol: potassium dihydrogen phosphate buffer (0.05 M, pH 3.5) (10:10:80) as mobile phase delivered at a flow rate of 1 mL/minute. Detection of PEQB and internal standard (1-([[3-(1,3-benzothiazol-2-ylsulfanyl)propyl]carbamoyl]amino)-N-phenylformamide) was performed at 235 nm and ambient temperature. Plasma samples (200 µL) were prepared by addition of 40 µL internal standard (100 µg/mL), and 400 µL acetonitrile. After vortex mixing and centrifugation at 10000 g, 50 µL of the clear supernatant was directly injected onto the chromatography column. Calibration curves were constructed by fitting the peak area ratio of the biuret to internal standard against concentration of biuret to a power model using generalized least squares nonlinear regression method. RESULTS: Under the above chromatography condition, biuret compound (PEQB) and the internal standard were detected at 4.5 and 13.5 minutes, respectively. Limit of quantitation of the PEQB was 0.1 µg/mL. Accuracy of the method over the concentration range of 0.1-100 µg/mL was between 88-109%. Inter- and intraday precisions were 4-19% and 6-8%, respectively. A good relationship in the form of a power model was found for two separate concentration ranges of 0.1-1 and 2.5-100 µg/mL (R (2)> 0.99). CONCLUSIONS: The presented simple HPLC method is sufficiently accurate, precise and sensitive for the quantitation of 1-(2-phenylethyl)-5-(quinaldin-4-yl) biuret in rat plasma. DocS 2013-05-04 2013 /pmc/articles/PMC3941904/ /pubmed/24624193 Text en Copyright © 2013, School of Pharmacy, Ahvaz Jundishapur University of Medical Sciences http://creativecommons.org/licenses/by/3/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Adibpour, Neda Ahmadnasr, Maryam Khodayar, Mohammad Javad Rezaee, Saeed Development and Validation of a High-Performance Liquid Chromatography Method With UV Detection for Determination of 1-(2-phenylethyl)-5- (quinaldin-4-yl) Biuret in Rat Plasma |
title | Development and Validation of a High-Performance Liquid Chromatography Method With UV Detection for Determination of 1-(2-phenylethyl)-5- (quinaldin-4-yl) Biuret in Rat Plasma |
title_full | Development and Validation of a High-Performance Liquid Chromatography Method With UV Detection for Determination of 1-(2-phenylethyl)-5- (quinaldin-4-yl) Biuret in Rat Plasma |
title_fullStr | Development and Validation of a High-Performance Liquid Chromatography Method With UV Detection for Determination of 1-(2-phenylethyl)-5- (quinaldin-4-yl) Biuret in Rat Plasma |
title_full_unstemmed | Development and Validation of a High-Performance Liquid Chromatography Method With UV Detection for Determination of 1-(2-phenylethyl)-5- (quinaldin-4-yl) Biuret in Rat Plasma |
title_short | Development and Validation of a High-Performance Liquid Chromatography Method With UV Detection for Determination of 1-(2-phenylethyl)-5- (quinaldin-4-yl) Biuret in Rat Plasma |
title_sort | development and validation of a high-performance liquid chromatography method with uv detection for determination of 1-(2-phenylethyl)-5- (quinaldin-4-yl) biuret in rat plasma |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3941904/ https://www.ncbi.nlm.nih.gov/pubmed/24624193 |
work_keys_str_mv | AT adibpourneda developmentandvalidationofahighperformanceliquidchromatographymethodwithuvdetectionfordeterminationof12phenylethyl5quinaldin4ylbiuretinratplasma AT ahmadnasrmaryam developmentandvalidationofahighperformanceliquidchromatographymethodwithuvdetectionfordeterminationof12phenylethyl5quinaldin4ylbiuretinratplasma AT khodayarmohammadjavad developmentandvalidationofahighperformanceliquidchromatographymethodwithuvdetectionfordeterminationof12phenylethyl5quinaldin4ylbiuretinratplasma AT rezaeesaeed developmentandvalidationofahighperformanceliquidchromatographymethodwithuvdetectionfordeterminationof12phenylethyl5quinaldin4ylbiuretinratplasma |