Cargando…

Correlation between microleakage and screw loosening at implant-abutment connection

PURPOSE: This study aimed to evaluate the correlation between microleakage and screw loosening at different types of implant-abutment connections and/or geometries measuring the torque values before and after the leakage tests. MATERIALS AND METHODS: Three different abutment types (Intenal hex titan...

Descripción completa

Detalles Bibliográficos
Autores principales: Sahin, Cem, Ayyildiz, Simel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Prosthodontics 2014
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3942525/
https://www.ncbi.nlm.nih.gov/pubmed/24605204
http://dx.doi.org/10.4047/jap.2014.6.1.35
_version_ 1782479088245538816
author Sahin, Cem
Ayyildiz, Simel
author_facet Sahin, Cem
Ayyildiz, Simel
author_sort Sahin, Cem
collection PubMed
description PURPOSE: This study aimed to evaluate the correlation between microleakage and screw loosening at different types of implant-abutment connections and/or geometries measuring the torque values before and after the leakage tests. MATERIALS AND METHODS: Three different abutment types (Intenal hex titanium, internal hex zirconium, morse tapered titaniuım) with different geometries were connected to its own implant fixture. All the abutments were tightened with a standard torque value then the composition was connected to the modified fluid filtration system. After the measurements of leakage removal torque values were re-measured. Kruskal-wallis test was performed for non-parametric and one-way ANOVA was performed for parametric data. The correlation was evaluated using Spearman Correlation Test (α=0.05). RESULTS: Significantly higher microleakage was found at the connection of implant-internal hex zirconium abutment. Observed mean torque value loss was also significantly higher than other connection geometries. Spearman tests revealed a significant correlation between microleakage and screw loosening. CONCLUSION: Microleakage may provoke screw loosening. Removing torque values rationally decrease with the increase of microleakage.
format Online
Article
Text
id pubmed-3942525
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher The Korean Academy of Prosthodontics
record_format MEDLINE/PubMed
spelling pubmed-39425252014-03-06 Correlation between microleakage and screw loosening at implant-abutment connection Sahin, Cem Ayyildiz, Simel J Adv Prosthodont PURPOSE: This study aimed to evaluate the correlation between microleakage and screw loosening at different types of implant-abutment connections and/or geometries measuring the torque values before and after the leakage tests. MATERIALS AND METHODS: Three different abutment types (Intenal hex titanium, internal hex zirconium, morse tapered titaniuım) with different geometries were connected to its own implant fixture. All the abutments were tightened with a standard torque value then the composition was connected to the modified fluid filtration system. After the measurements of leakage removal torque values were re-measured. Kruskal-wallis test was performed for non-parametric and one-way ANOVA was performed for parametric data. The correlation was evaluated using Spearman Correlation Test (α=0.05). RESULTS: Significantly higher microleakage was found at the connection of implant-internal hex zirconium abutment. Observed mean torque value loss was also significantly higher than other connection geometries. Spearman tests revealed a significant correlation between microleakage and screw loosening. CONCLUSION: Microleakage may provoke screw loosening. Removing torque values rationally decrease with the increase of microleakage. The Korean Academy of Prosthodontics 2014-02 2014-02-14 /pmc/articles/PMC3942525/ /pubmed/24605204 http://dx.doi.org/10.4047/jap.2014.6.1.35 Text en © 2014 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Sahin, Cem
Ayyildiz, Simel
Correlation between microleakage and screw loosening at implant-abutment connection
title Correlation between microleakage and screw loosening at implant-abutment connection
title_full Correlation between microleakage and screw loosening at implant-abutment connection
title_fullStr Correlation between microleakage and screw loosening at implant-abutment connection
title_full_unstemmed Correlation between microleakage and screw loosening at implant-abutment connection
title_short Correlation between microleakage and screw loosening at implant-abutment connection
title_sort correlation between microleakage and screw loosening at implant-abutment connection
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3942525/
https://www.ncbi.nlm.nih.gov/pubmed/24605204
http://dx.doi.org/10.4047/jap.2014.6.1.35
work_keys_str_mv AT sahincem correlationbetweenmicroleakageandscrewlooseningatimplantabutmentconnection
AT ayyildizsimel correlationbetweenmicroleakageandscrewlooseningatimplantabutmentconnection