Cargando…
Structural analysis and corrosion studies on an ISO 5832-9 biomedical alloy with TiO(2) sol–gel layers
The aim of this study was to demonstrate the relationship between the structural and corrosion properties of an ISO 5832-9 biomedical alloy modified with titanium dioxide (TiO(2)) layers. These layers were obtained via the sol–gel method by acid-catalyzed hydrolysis of titanium isopropoxide in isopr...
Autores principales: | Burnat, B., Dercz, G., Blaszczyk, T. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3942627/ https://www.ncbi.nlm.nih.gov/pubmed/24271113 http://dx.doi.org/10.1007/s10856-013-5099-7 |
Ejemplares similares
-
Optimizing the layer thickness of sol–gel-derived TiO(2) coating on polyetheretherketone
por: Hayashi, Makoto, et al.
Publicado: (2021) -
Foldable and Cytocompatible Sol-gel TiO(2) Photonics
por: Li, Lan, et al.
Publicado: (2015) -
Biocompatibility and Corrosion Protection Behaviour of Hydroxyapatite Sol-Gel-Derived Coatings on Ti6Al4V Alloy
por: El Hadad, Amir A., et al.
Publicado: (2017) -
Duplex Coating Combing Vanadate-Intercalated Layered Double Hydroxide and Ce-Doped Sol–Gel Layers on Aluminum Alloy for Active Corrosion Protection
por: Wei, Kai, et al.
Publicado: (2023) -
Hybrid Sol-Gel Coatings Doped with Non-Toxic Corrosion Inhibitors for Corrosion Protection on AZ61 Magnesium Alloy
por: Rodríguez-Alonso, Luis, et al.
Publicado: (2022)