Cargando…
Qualitative and Quantitative Contrast Enhanced Ultrasonography of the Pancreas Using Bolus Injection and Continuous Infusion Methods in Normal Dogs
Quantitative contrast enhanced ultrasound is a major breakthrough for ultrasound imaging in recent years. However, contrast enhancement of the pancreas is brief with bolus injection. To assess if continuous infusion of Sonazoid(®) can prolong the duration of pancreatic enhancement over bolus injecti...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japanese Society of Veterinary Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3942965/ https://www.ncbi.nlm.nih.gov/pubmed/23955397 http://dx.doi.org/10.1292/jvms.13-0199 |
_version_ | 1782479151494594560 |
---|---|
author | LIM, Sue Yee NAKAMURA, Kensuke MORISHITA, Keitaro SASAKI, Noboru MURAKAMI, Masahiro OSUGA, Tatsuyuki OHTA, Hiroshi YAMASAKI, Masahiro TAKIGUCHI, Mitsuyoshi |
author_facet | LIM, Sue Yee NAKAMURA, Kensuke MORISHITA, Keitaro SASAKI, Noboru MURAKAMI, Masahiro OSUGA, Tatsuyuki OHTA, Hiroshi YAMASAKI, Masahiro TAKIGUCHI, Mitsuyoshi |
author_sort | LIM, Sue Yee |
collection | PubMed |
description | Quantitative contrast enhanced ultrasound is a major breakthrough for ultrasound imaging in recent years. However, contrast enhancement of the pancreas is brief with bolus injection. To assess if continuous infusion of Sonazoid(®) can prolong the duration of pancreatic enhancement over bolus injections, eight adult dogs received bolus injection and continuous infusion of Sonazoid(®) on separate days. Contrast enhanced ultrasound of the pancreatic parenchyma and proximal descending duodenum was performed, and time intensity curves reflecting tissue perfusions were generated. Perfusion parameters- time to initial upslope, peak time, time to wash-out and peak intensity were calculated and evaluated. Fast wash-in to intense peak, followed by rapid wash-out was observed for time intensity curves of bolus injection. With continuous infusion, contrast wash-in to peak intensity was gradual, followed by long plateau and slow wash-out. Median contrast enhancement durations of the pancreas and duodenum were significantly prolonged by continuous infusion from 11 sec (range, 10 to 23 sec) and 16 sec (range, 3 to 43 sec) at bolus injection to 205 sec (range, 170 to 264 sec, P<0.01) and 193 sec (range, 169 to 216 sec, P<0.05), respectively. Median peak intensity of the pancreas was 100.9 MPV (range, 80.2 to 124.3 MPV) at bolus injection and 77.6 MPV (range, 58.2 to 99.5 MPV, P<0.05) at continuous infusion. Prolonged continuous imaging is afforded by continuous infusion of contrast agent. Peak intensity of the pancreas was slightly diminished in continuous infusion, but offered adequate imaging subjectively. |
format | Online Article Text |
id | pubmed-3942965 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | The Japanese Society of Veterinary Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-39429652014-04-22 Qualitative and Quantitative Contrast Enhanced Ultrasonography of the Pancreas Using Bolus Injection and Continuous Infusion Methods in Normal Dogs LIM, Sue Yee NAKAMURA, Kensuke MORISHITA, Keitaro SASAKI, Noboru MURAKAMI, Masahiro OSUGA, Tatsuyuki OHTA, Hiroshi YAMASAKI, Masahiro TAKIGUCHI, Mitsuyoshi J Vet Med Sci Internal Medicine Quantitative contrast enhanced ultrasound is a major breakthrough for ultrasound imaging in recent years. However, contrast enhancement of the pancreas is brief with bolus injection. To assess if continuous infusion of Sonazoid(®) can prolong the duration of pancreatic enhancement over bolus injections, eight adult dogs received bolus injection and continuous infusion of Sonazoid(®) on separate days. Contrast enhanced ultrasound of the pancreatic parenchyma and proximal descending duodenum was performed, and time intensity curves reflecting tissue perfusions were generated. Perfusion parameters- time to initial upslope, peak time, time to wash-out and peak intensity were calculated and evaluated. Fast wash-in to intense peak, followed by rapid wash-out was observed for time intensity curves of bolus injection. With continuous infusion, contrast wash-in to peak intensity was gradual, followed by long plateau and slow wash-out. Median contrast enhancement durations of the pancreas and duodenum were significantly prolonged by continuous infusion from 11 sec (range, 10 to 23 sec) and 16 sec (range, 3 to 43 sec) at bolus injection to 205 sec (range, 170 to 264 sec, P<0.01) and 193 sec (range, 169 to 216 sec, P<0.05), respectively. Median peak intensity of the pancreas was 100.9 MPV (range, 80.2 to 124.3 MPV) at bolus injection and 77.6 MPV (range, 58.2 to 99.5 MPV, P<0.05) at continuous infusion. Prolonged continuous imaging is afforded by continuous infusion of contrast agent. Peak intensity of the pancreas was slightly diminished in continuous infusion, but offered adequate imaging subjectively. The Japanese Society of Veterinary Science 2013-08-13 2013-12 /pmc/articles/PMC3942965/ /pubmed/23955397 http://dx.doi.org/10.1292/jvms.13-0199 Text en ©2013 The Japanese Society of Veterinary Science http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. |
spellingShingle | Internal Medicine LIM, Sue Yee NAKAMURA, Kensuke MORISHITA, Keitaro SASAKI, Noboru MURAKAMI, Masahiro OSUGA, Tatsuyuki OHTA, Hiroshi YAMASAKI, Masahiro TAKIGUCHI, Mitsuyoshi Qualitative and Quantitative Contrast Enhanced Ultrasonography of the Pancreas Using Bolus Injection and Continuous Infusion Methods in Normal Dogs |
title | Qualitative and Quantitative Contrast Enhanced Ultrasonography of the
Pancreas Using Bolus Injection and Continuous Infusion Methods in Normal
Dogs |
title_full | Qualitative and Quantitative Contrast Enhanced Ultrasonography of the
Pancreas Using Bolus Injection and Continuous Infusion Methods in Normal
Dogs |
title_fullStr | Qualitative and Quantitative Contrast Enhanced Ultrasonography of the
Pancreas Using Bolus Injection and Continuous Infusion Methods in Normal
Dogs |
title_full_unstemmed | Qualitative and Quantitative Contrast Enhanced Ultrasonography of the
Pancreas Using Bolus Injection and Continuous Infusion Methods in Normal
Dogs |
title_short | Qualitative and Quantitative Contrast Enhanced Ultrasonography of the
Pancreas Using Bolus Injection and Continuous Infusion Methods in Normal
Dogs |
title_sort | qualitative and quantitative contrast enhanced ultrasonography of the
pancreas using bolus injection and continuous infusion methods in normal
dogs |
topic | Internal Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3942965/ https://www.ncbi.nlm.nih.gov/pubmed/23955397 http://dx.doi.org/10.1292/jvms.13-0199 |
work_keys_str_mv | AT limsueyee qualitativeandquantitativecontrastenhancedultrasonographyofthepancreasusingbolusinjectionandcontinuousinfusionmethodsinnormaldogs AT nakamurakensuke qualitativeandquantitativecontrastenhancedultrasonographyofthepancreasusingbolusinjectionandcontinuousinfusionmethodsinnormaldogs AT morishitakeitaro qualitativeandquantitativecontrastenhancedultrasonographyofthepancreasusingbolusinjectionandcontinuousinfusionmethodsinnormaldogs AT sasakinoboru qualitativeandquantitativecontrastenhancedultrasonographyofthepancreasusingbolusinjectionandcontinuousinfusionmethodsinnormaldogs AT murakamimasahiro qualitativeandquantitativecontrastenhancedultrasonographyofthepancreasusingbolusinjectionandcontinuousinfusionmethodsinnormaldogs AT osugatatsuyuki qualitativeandquantitativecontrastenhancedultrasonographyofthepancreasusingbolusinjectionandcontinuousinfusionmethodsinnormaldogs AT ohtahiroshi qualitativeandquantitativecontrastenhancedultrasonographyofthepancreasusingbolusinjectionandcontinuousinfusionmethodsinnormaldogs AT yamasakimasahiro qualitativeandquantitativecontrastenhancedultrasonographyofthepancreasusingbolusinjectionandcontinuousinfusionmethodsinnormaldogs AT takiguchimitsuyoshi qualitativeandquantitativecontrastenhancedultrasonographyofthepancreasusingbolusinjectionandcontinuousinfusionmethodsinnormaldogs |