Sensitivity of individual and mini-pool nucleic acid testing assessed by dilution of hepatitis B nucleic acid testing yield samples

INTRODUCTION: For nucleic acid testing (NAT) of blood donations, either the blood samples can be pooled together in a batch of six or eight prior to testing (mini-pool-NAT [MP-NAT]), or the tests can be run on every individual sample (individual donor-NAT [ID-NAT]). It has been debated in various st...

Descripción completa

Detalles Bibliográficos
Autores principales: Chatterjee, Kabita, Agarwal, Nitin, Coshic, Poonam, Borgohain, Mayuri, Chakroborty, Sourit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3943140/
https://www.ncbi.nlm.nih.gov/pubmed/24678169
http://dx.doi.org/10.4103/0973-6247.126684
_version_ 1782479184299294720
author Chatterjee, Kabita
Agarwal, Nitin
Coshic, Poonam
Borgohain, Mayuri
Chakroborty, Sourit
author_facet Chatterjee, Kabita
Agarwal, Nitin
Coshic, Poonam
Borgohain, Mayuri
Chakroborty, Sourit
author_sort Chatterjee, Kabita
collection PubMed
description INTRODUCTION: For nucleic acid testing (NAT) of blood donations, either the blood samples can be pooled together in a batch of six or eight prior to testing (mini-pool-NAT [MP-NAT]), or the tests can be run on every individual sample (individual donor-NAT [ID-NAT]). It has been debated in various studies whether pooling of samples results in decreased sensitivity of detection as the volume of individual samples gets lesser in a pool. The objective of this study was to investigate the effect of dilution on the sensitivity of tests. MATERIALS AND METHODS: The study was performesd on nine plasma samples which were hepatitis B reactive exclusively by Procleix Ultrio Plus and not by Procleix Ultrio or serology. These nine exclusive UltrioPlus ID-NAT yield samples were diluted in 1:2, 1:4. 1:6 and 1:8 dilutions using previously tested negative plasma and each dilution of every sample along with archived undiluted sample were retested in three replicates with Procleix Ultrio Plus Assay. RESULTS: Among NAT yield samples, 88.88% of the samples were detected when retested in ID-NAT in undiluted form. Samples with higher viral load (sample 5 and 6) were detected by all dilutions. When samples with viral load below 20 IU/mL were tested in dilutions of 1:6 or 1:8, only 9 out of 27 replicates (33.33%) were detected. This means that more than 67% of low viral load samples were missed by MP-NAT of 1:6 or 1:8 dilution out of total NAT yield samples. CONCLUSION: Individual Donor NAT is ideal methodology for NAT as dilution due to pooling may miss samples with low viral load as evident in this study.
format Online
Article
Text
id pubmed-3943140
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-39431402014-03-27 Sensitivity of individual and mini-pool nucleic acid testing assessed by dilution of hepatitis B nucleic acid testing yield samples Chatterjee, Kabita Agarwal, Nitin Coshic, Poonam Borgohain, Mayuri Chakroborty, Sourit Asian J Transfus Sci Original Article INTRODUCTION: For nucleic acid testing (NAT) of blood donations, either the blood samples can be pooled together in a batch of six or eight prior to testing (mini-pool-NAT [MP-NAT]), or the tests can be run on every individual sample (individual donor-NAT [ID-NAT]). It has been debated in various studies whether pooling of samples results in decreased sensitivity of detection as the volume of individual samples gets lesser in a pool. The objective of this study was to investigate the effect of dilution on the sensitivity of tests. MATERIALS AND METHODS: The study was performesd on nine plasma samples which were hepatitis B reactive exclusively by Procleix Ultrio Plus and not by Procleix Ultrio or serology. These nine exclusive UltrioPlus ID-NAT yield samples were diluted in 1:2, 1:4. 1:6 and 1:8 dilutions using previously tested negative plasma and each dilution of every sample along with archived undiluted sample were retested in three replicates with Procleix Ultrio Plus Assay. RESULTS: Among NAT yield samples, 88.88% of the samples were detected when retested in ID-NAT in undiluted form. Samples with higher viral load (sample 5 and 6) were detected by all dilutions. When samples with viral load below 20 IU/mL were tested in dilutions of 1:6 or 1:8, only 9 out of 27 replicates (33.33%) were detected. This means that more than 67% of low viral load samples were missed by MP-NAT of 1:6 or 1:8 dilution out of total NAT yield samples. CONCLUSION: Individual Donor NAT is ideal methodology for NAT as dilution due to pooling may miss samples with low viral load as evident in this study. Medknow Publications & Media Pvt Ltd 2014 /pmc/articles/PMC3943140/ /pubmed/24678169 http://dx.doi.org/10.4103/0973-6247.126684 Text en Copyright: © Asian Journal of Transfusion Science http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Chatterjee, Kabita
Agarwal, Nitin
Coshic, Poonam
Borgohain, Mayuri
Chakroborty, Sourit
Sensitivity of individual and mini-pool nucleic acid testing assessed by dilution of hepatitis B nucleic acid testing yield samples
title Sensitivity of individual and mini-pool nucleic acid testing assessed by dilution of hepatitis B nucleic acid testing yield samples
title_full Sensitivity of individual and mini-pool nucleic acid testing assessed by dilution of hepatitis B nucleic acid testing yield samples
title_fullStr Sensitivity of individual and mini-pool nucleic acid testing assessed by dilution of hepatitis B nucleic acid testing yield samples
title_full_unstemmed Sensitivity of individual and mini-pool nucleic acid testing assessed by dilution of hepatitis B nucleic acid testing yield samples
title_short Sensitivity of individual and mini-pool nucleic acid testing assessed by dilution of hepatitis B nucleic acid testing yield samples
title_sort sensitivity of individual and mini-pool nucleic acid testing assessed by dilution of hepatitis b nucleic acid testing yield samples
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3943140/
https://www.ncbi.nlm.nih.gov/pubmed/24678169
http://dx.doi.org/10.4103/0973-6247.126684
work_keys_str_mv AT chatterjeekabita sensitivityofindividualandminipoolnucleicacidtestingassessedbydilutionofhepatitisbnucleicacidtestingyieldsamples
AT agarwalnitin sensitivityofindividualandminipoolnucleicacidtestingassessedbydilutionofhepatitisbnucleicacidtestingyieldsamples
AT coshicpoonam sensitivityofindividualandminipoolnucleicacidtestingassessedbydilutionofhepatitisbnucleicacidtestingyieldsamples
AT borgohainmayuri sensitivityofindividualandminipoolnucleicacidtestingassessedbydilutionofhepatitisbnucleicacidtestingyieldsamples
AT chakrobortysourit sensitivityofindividualandminipoolnucleicacidtestingassessedbydilutionofhepatitisbnucleicacidtestingyieldsamples