Cargando…

Quantifying Short-Lived Events in Multistate Ionic Current Measurements

[Image: see text] We developed a generalized technique to characterize polymer–nanopore interactions via single channel ionic current measurements. Physical interactions between analytes, such as DNA, proteins, or synthetic polymers, and a nanopore cause multiple discrete states in the current. We m...

Descripción completa

Detalles Bibliográficos
Autores principales: Balijepalli, Arvind, Ettedgui, Jessica, Cornio, Andrew T., Robertson, Joseph W. F., Cheung, Kin P., Kasianowicz, John J., Vaz, Canute
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2014
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3943493/
https://www.ncbi.nlm.nih.gov/pubmed/24397836
http://dx.doi.org/10.1021/nn405761y
_version_ 1782306276291641344
author Balijepalli, Arvind
Ettedgui, Jessica
Cornio, Andrew T.
Robertson, Joseph W. F.
Cheung, Kin P.
Kasianowicz, John J.
Vaz, Canute
author_facet Balijepalli, Arvind
Ettedgui, Jessica
Cornio, Andrew T.
Robertson, Joseph W. F.
Cheung, Kin P.
Kasianowicz, John J.
Vaz, Canute
author_sort Balijepalli, Arvind
collection PubMed
description [Image: see text] We developed a generalized technique to characterize polymer–nanopore interactions via single channel ionic current measurements. Physical interactions between analytes, such as DNA, proteins, or synthetic polymers, and a nanopore cause multiple discrete states in the current. We modeled the transitions of the current to individual states with an equivalent electrical circuit, which allowed us to describe the system response. This enabled the estimation of short-lived states that are presently not characterized by existing analysis techniques. Our approach considerably improves the range and resolution of single-molecule characterization with nanopores. For example, we characterized the residence times of synthetic polymers that are three times shorter than those estimated with existing algorithms. Because the molecule’s residence time follows an exponential distribution, we recover nearly 20-fold more events per unit time that can be used for analysis. Furthermore, the measurement range was extended from 11 monomers to as few as 8. Finally, we applied this technique to recover a known sequence of single-stranded DNA from previously published ion channel recordings, identifying discrete current states with subpicoampere resolution.
format Online
Article
Text
id pubmed-3943493
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-39434932015-01-07 Quantifying Short-Lived Events in Multistate Ionic Current Measurements Balijepalli, Arvind Ettedgui, Jessica Cornio, Andrew T. Robertson, Joseph W. F. Cheung, Kin P. Kasianowicz, John J. Vaz, Canute ACS Nano [Image: see text] We developed a generalized technique to characterize polymer–nanopore interactions via single channel ionic current measurements. Physical interactions between analytes, such as DNA, proteins, or synthetic polymers, and a nanopore cause multiple discrete states in the current. We modeled the transitions of the current to individual states with an equivalent electrical circuit, which allowed us to describe the system response. This enabled the estimation of short-lived states that are presently not characterized by existing analysis techniques. Our approach considerably improves the range and resolution of single-molecule characterization with nanopores. For example, we characterized the residence times of synthetic polymers that are three times shorter than those estimated with existing algorithms. Because the molecule’s residence time follows an exponential distribution, we recover nearly 20-fold more events per unit time that can be used for analysis. Furthermore, the measurement range was extended from 11 monomers to as few as 8. Finally, we applied this technique to recover a known sequence of single-stranded DNA from previously published ion channel recordings, identifying discrete current states with subpicoampere resolution. American Chemical Society 2014-01-07 2014-02-25 /pmc/articles/PMC3943493/ /pubmed/24397836 http://dx.doi.org/10.1021/nn405761y Text en Copyright © 2014 U.S. Government
spellingShingle Balijepalli, Arvind
Ettedgui, Jessica
Cornio, Andrew T.
Robertson, Joseph W. F.
Cheung, Kin P.
Kasianowicz, John J.
Vaz, Canute
Quantifying Short-Lived Events in Multistate Ionic Current Measurements
title Quantifying Short-Lived Events in Multistate Ionic Current Measurements
title_full Quantifying Short-Lived Events in Multistate Ionic Current Measurements
title_fullStr Quantifying Short-Lived Events in Multistate Ionic Current Measurements
title_full_unstemmed Quantifying Short-Lived Events in Multistate Ionic Current Measurements
title_short Quantifying Short-Lived Events in Multistate Ionic Current Measurements
title_sort quantifying short-lived events in multistate ionic current measurements
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3943493/
https://www.ncbi.nlm.nih.gov/pubmed/24397836
http://dx.doi.org/10.1021/nn405761y
work_keys_str_mv AT balijepalliarvind quantifyingshortlivedeventsinmultistateioniccurrentmeasurements
AT ettedguijessica quantifyingshortlivedeventsinmultistateioniccurrentmeasurements
AT cornioandrewt quantifyingshortlivedeventsinmultistateioniccurrentmeasurements
AT robertsonjosephwf quantifyingshortlivedeventsinmultistateioniccurrentmeasurements
AT cheungkinp quantifyingshortlivedeventsinmultistateioniccurrentmeasurements
AT kasianowiczjohnj quantifyingshortlivedeventsinmultistateioniccurrentmeasurements
AT vazcanute quantifyingshortlivedeventsinmultistateioniccurrentmeasurements