A Cause of Falsely High Noise Level in Signal Averaged Electrocardiogram Recordings
Signal averaged electrocardiogram (SAECG) is a well-established noninvasive method of exploration in patients at risk for sudden cardiac death. The time-domain SAECG analysis has a set of well-defined standards, including the value of accepted noise level. In very rare instances, the final noise lev...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medical University Publishing House Craiova
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3945385/ https://www.ncbi.nlm.nih.gov/pubmed/24778836 |
_version_ | 1782306514874138624 |
---|---|
author | Donoiu, I. Mustafa, Roxana Edmee Ionescu, D.D. |
author_facet | Donoiu, I. Mustafa, Roxana Edmee Ionescu, D.D. |
author_sort | Donoiu, I. |
collection | PubMed |
description | Signal averaged electrocardiogram (SAECG) is a well-established noninvasive method of exploration in patients at risk for sudden cardiac death. The time-domain SAECG analysis has a set of well-defined standards, including the value of accepted noise level. In very rare instances, the final noise level appears to remain unacceptably high even after carefully preparing the skin of the patient and averaging a great number of QRS complexes. We encountered three such cases in patients who had a SAECG done for a 40 Hz high-pass filter, which showed a high noise level in contrast with the visual impression of a good quality of the recording. |
format | Online Article Text |
id | pubmed-3945385 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Medical University Publishing House Craiova |
record_format | MEDLINE/PubMed |
spelling | pubmed-39453852014-04-28 A Cause of Falsely High Noise Level in Signal Averaged Electrocardiogram Recordings Donoiu, I. Mustafa, Roxana Edmee Ionescu, D.D. Curr Health Sci J Case Report Signal averaged electrocardiogram (SAECG) is a well-established noninvasive method of exploration in patients at risk for sudden cardiac death. The time-domain SAECG analysis has a set of well-defined standards, including the value of accepted noise level. In very rare instances, the final noise level appears to remain unacceptably high even after carefully preparing the skin of the patient and averaging a great number of QRS complexes. We encountered three such cases in patients who had a SAECG done for a 40 Hz high-pass filter, which showed a high noise level in contrast with the visual impression of a good quality of the recording. Medical University Publishing House Craiova 2011 2011-11-28 /pmc/articles/PMC3945385/ /pubmed/24778836 Text en Copyright © 2011, Medical University Publishing House Craiova |
spellingShingle | Case Report Donoiu, I. Mustafa, Roxana Edmee Ionescu, D.D. A Cause of Falsely High Noise Level in Signal Averaged Electrocardiogram Recordings |
title | A Cause of Falsely High Noise Level in Signal Averaged Electrocardiogram Recordings |
title_full | A Cause of Falsely High Noise Level in Signal Averaged Electrocardiogram Recordings |
title_fullStr | A Cause of Falsely High Noise Level in Signal Averaged Electrocardiogram Recordings |
title_full_unstemmed | A Cause of Falsely High Noise Level in Signal Averaged Electrocardiogram Recordings |
title_short | A Cause of Falsely High Noise Level in Signal Averaged Electrocardiogram Recordings |
title_sort | cause of falsely high noise level in signal averaged electrocardiogram recordings |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3945385/ https://www.ncbi.nlm.nih.gov/pubmed/24778836 |
work_keys_str_mv | AT donoiui acauseoffalselyhighnoiselevelinsignalaveragedelectrocardiogramrecordings AT mustafaroxanaedmee acauseoffalselyhighnoiselevelinsignalaveragedelectrocardiogramrecordings AT ionescudd acauseoffalselyhighnoiselevelinsignalaveragedelectrocardiogramrecordings AT donoiui causeoffalselyhighnoiselevelinsignalaveragedelectrocardiogramrecordings AT mustafaroxanaedmee causeoffalselyhighnoiselevelinsignalaveragedelectrocardiogramrecordings AT ionescudd causeoffalselyhighnoiselevelinsignalaveragedelectrocardiogramrecordings |