Cargando…

A Cause of Falsely High Noise Level in Signal Averaged Electrocardiogram Recordings

Signal averaged electrocardiogram (SAECG) is a well-established noninvasive method of exploration in patients at risk for sudden cardiac death. The time-domain SAECG analysis has a set of well-defined standards, including the value of accepted noise level. In very rare instances, the final noise lev...

Descripción completa

Detalles Bibliográficos
Autores principales: Donoiu, I., Mustafa, Roxana Edmee, Ionescu, D.D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medical University Publishing House Craiova 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3945385/
https://www.ncbi.nlm.nih.gov/pubmed/24778836
_version_ 1782306514874138624
author Donoiu, I.
Mustafa, Roxana Edmee
Ionescu, D.D.
author_facet Donoiu, I.
Mustafa, Roxana Edmee
Ionescu, D.D.
author_sort Donoiu, I.
collection PubMed
description Signal averaged electrocardiogram (SAECG) is a well-established noninvasive method of exploration in patients at risk for sudden cardiac death. The time-domain SAECG analysis has a set of well-defined standards, including the value of accepted noise level. In very rare instances, the final noise level appears to remain unacceptably high even after carefully preparing the skin of the patient and averaging a great number of QRS complexes. We encountered three such cases in patients who had a SAECG done for a 40 Hz high-pass filter, which showed a high noise level in contrast with the visual impression of a good quality of the recording.
format Online
Article
Text
id pubmed-3945385
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Medical University Publishing House Craiova
record_format MEDLINE/PubMed
spelling pubmed-39453852014-04-28 A Cause of Falsely High Noise Level in Signal Averaged Electrocardiogram Recordings Donoiu, I. Mustafa, Roxana Edmee Ionescu, D.D. Curr Health Sci J Case Report Signal averaged electrocardiogram (SAECG) is a well-established noninvasive method of exploration in patients at risk for sudden cardiac death. The time-domain SAECG analysis has a set of well-defined standards, including the value of accepted noise level. In very rare instances, the final noise level appears to remain unacceptably high even after carefully preparing the skin of the patient and averaging a great number of QRS complexes. We encountered three such cases in patients who had a SAECG done for a 40 Hz high-pass filter, which showed a high noise level in contrast with the visual impression of a good quality of the recording. Medical University Publishing House Craiova 2011 2011-11-28 /pmc/articles/PMC3945385/ /pubmed/24778836 Text en Copyright © 2011, Medical University Publishing House Craiova
spellingShingle Case Report
Donoiu, I.
Mustafa, Roxana Edmee
Ionescu, D.D.
A Cause of Falsely High Noise Level in Signal Averaged Electrocardiogram Recordings
title A Cause of Falsely High Noise Level in Signal Averaged Electrocardiogram Recordings
title_full A Cause of Falsely High Noise Level in Signal Averaged Electrocardiogram Recordings
title_fullStr A Cause of Falsely High Noise Level in Signal Averaged Electrocardiogram Recordings
title_full_unstemmed A Cause of Falsely High Noise Level in Signal Averaged Electrocardiogram Recordings
title_short A Cause of Falsely High Noise Level in Signal Averaged Electrocardiogram Recordings
title_sort cause of falsely high noise level in signal averaged electrocardiogram recordings
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3945385/
https://www.ncbi.nlm.nih.gov/pubmed/24778836
work_keys_str_mv AT donoiui acauseoffalselyhighnoiselevelinsignalaveragedelectrocardiogramrecordings
AT mustafaroxanaedmee acauseoffalselyhighnoiselevelinsignalaveragedelectrocardiogramrecordings
AT ionescudd acauseoffalselyhighnoiselevelinsignalaveragedelectrocardiogramrecordings
AT donoiui causeoffalselyhighnoiselevelinsignalaveragedelectrocardiogramrecordings
AT mustafaroxanaedmee causeoffalselyhighnoiselevelinsignalaveragedelectrocardiogramrecordings
AT ionescudd causeoffalselyhighnoiselevelinsignalaveragedelectrocardiogramrecordings