Cargando…

Evaluation of Respirable Crystalline Silica in High School Ceramics Classrooms

Air concentrations of respirable crystalline silica were measured in eleven (11) high school ceramics classrooms located in Salt Lake County, UT, USA. Respirable dust was collected on PVC filters using precision flow pumps and cyclone samplers (n = 44). Filters were subsequently analyzed for respira...

Descripción completa

Detalles Bibliográficos
Autores principales: Fechser, Matthew, Alaves, Victor, Larson, Rodney, Sleeth, Darrah
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2014
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3945536/
https://www.ncbi.nlm.nih.gov/pubmed/24464235
http://dx.doi.org/10.3390/ijerph110201250
Descripción
Sumario:Air concentrations of respirable crystalline silica were measured in eleven (11) high school ceramics classrooms located in Salt Lake County, UT, USA. Respirable dust was collected on PVC filters using precision flow pumps and cyclone samplers (n = 44). Filters were subsequently analyzed for respirable dust and percent crystalline silica content. The geometric mean of the silica concentrations was 0.009 mg/m(3) near the teacher’s work station and 0.008 mg/m(3) near the kilns. The number of students in the classroom was correlated to the silica concentration in the ceramics classroom, but no correlation was found between the silica concentrations and either the size of the classroom or the age of the building. Results from this study indicate that ceramics teachers may be at an increased risk of exposure to crystalline silica based on the ACGIH TLV of 0.025 mg/m(3), with an exceedance of 21%.