Cargando…

Comparison of the glidescope®, flexible fibreoptic intubating bronchoscope, iPhone modified bronchoscope, and the Macintosh laryngoscope in normal and difficult airways: a manikin study

BACKGROUND: Smart phone technology is becoming increasingly integrated into medical care. Our study compared an iPhone modified flexible fibreoptic bronchoscope as an intubation aid and clinical teaching tool with an unmodified bronchoscope, Glidescope® and Macintosh laryngoscope in a simulated norm...

Descripción completa

Detalles Bibliográficos
Autores principales: Langley, Adrian, Mar Fan, Gabriel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3945614/
https://www.ncbi.nlm.nih.gov/pubmed/24575885
http://dx.doi.org/10.1186/1471-2253-14-10
_version_ 1782306552387993600
author Langley, Adrian
Mar Fan, Gabriel
author_facet Langley, Adrian
Mar Fan, Gabriel
author_sort Langley, Adrian
collection PubMed
description BACKGROUND: Smart phone technology is becoming increasingly integrated into medical care. Our study compared an iPhone modified flexible fibreoptic bronchoscope as an intubation aid and clinical teaching tool with an unmodified bronchoscope, Glidescope® and Macintosh laryngoscope in a simulated normal and difficult airway scenario. METHODS: Sixty three anaesthesia providers, 21 consultant anaesthetists, 21 registrars and 21 anaesthetic nurses attempted to intubate a MegaCode Kelly™ manikin, comparing a normal and difficult airway scenario for each device. Primary endpoints were time to view the vocal cords (TVC), time to successful intubation (TSI) and number of failed intubations with each device. Secondary outcomes included participant rated device usability and preference for each scenario. Advantages and disadvantages of the iPhone modified bronchoscope were also discussed. RESULTS: There was no significant difference in TVC with the iPhone modified bronchoscope compared with the Macintosh blade (P = 1.0) or unmodified bronchoscope (P = 0.155). TVC was significantly shorter with the Glidescope compared with the Macintosh blade (P < 0.001), iPhone (P < 0.001) and unmodified bronchoscope (P = 0.011). The iPhone bronchoscope TSI was significantly longer than all other devices (P < 0.001). There was no difference between anaesthetic consultant or registrar TVC (P = 1.0) or TSI (P = 0.252), with both being less than the nurses (P < 0.001). Consultant anaesthetists and nurses had a higher intubation failure rate with the iPhone modified bronchoscope compared with the registrars. Although more difficult to use, similar proportions of consultants (14/21), registrars (15/21) and nurses (15/21) indicated that they would be prepared to use the iPhone modified bronchoscope in their clinical practice. The Glidescope was rated easiest to use (P < 0.001) and was the preferred device by all participants for the difficult airway scenario. CONCLUSIONS: The iPhone modified bronchoscope, in its current configuration, was found to be more difficult to use compared with the Glidescope® and unmodified bronchoscope; however it offered several advantages for teaching fibreoptic intubation technique when video-assisted bronchoscopy was unavailable.
format Online
Article
Text
id pubmed-3945614
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-39456142014-03-08 Comparison of the glidescope®, flexible fibreoptic intubating bronchoscope, iPhone modified bronchoscope, and the Macintosh laryngoscope in normal and difficult airways: a manikin study Langley, Adrian Mar Fan, Gabriel BMC Anesthesiol Research Article BACKGROUND: Smart phone technology is becoming increasingly integrated into medical care. Our study compared an iPhone modified flexible fibreoptic bronchoscope as an intubation aid and clinical teaching tool with an unmodified bronchoscope, Glidescope® and Macintosh laryngoscope in a simulated normal and difficult airway scenario. METHODS: Sixty three anaesthesia providers, 21 consultant anaesthetists, 21 registrars and 21 anaesthetic nurses attempted to intubate a MegaCode Kelly™ manikin, comparing a normal and difficult airway scenario for each device. Primary endpoints were time to view the vocal cords (TVC), time to successful intubation (TSI) and number of failed intubations with each device. Secondary outcomes included participant rated device usability and preference for each scenario. Advantages and disadvantages of the iPhone modified bronchoscope were also discussed. RESULTS: There was no significant difference in TVC with the iPhone modified bronchoscope compared with the Macintosh blade (P = 1.0) or unmodified bronchoscope (P = 0.155). TVC was significantly shorter with the Glidescope compared with the Macintosh blade (P < 0.001), iPhone (P < 0.001) and unmodified bronchoscope (P = 0.011). The iPhone bronchoscope TSI was significantly longer than all other devices (P < 0.001). There was no difference between anaesthetic consultant or registrar TVC (P = 1.0) or TSI (P = 0.252), with both being less than the nurses (P < 0.001). Consultant anaesthetists and nurses had a higher intubation failure rate with the iPhone modified bronchoscope compared with the registrars. Although more difficult to use, similar proportions of consultants (14/21), registrars (15/21) and nurses (15/21) indicated that they would be prepared to use the iPhone modified bronchoscope in their clinical practice. The Glidescope was rated easiest to use (P < 0.001) and was the preferred device by all participants for the difficult airway scenario. CONCLUSIONS: The iPhone modified bronchoscope, in its current configuration, was found to be more difficult to use compared with the Glidescope® and unmodified bronchoscope; however it offered several advantages for teaching fibreoptic intubation technique when video-assisted bronchoscopy was unavailable. BioMed Central 2014-02-28 /pmc/articles/PMC3945614/ /pubmed/24575885 http://dx.doi.org/10.1186/1471-2253-14-10 Text en Copyright © 2014 Langley and Mar Fan; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Langley, Adrian
Mar Fan, Gabriel
Comparison of the glidescope®, flexible fibreoptic intubating bronchoscope, iPhone modified bronchoscope, and the Macintosh laryngoscope in normal and difficult airways: a manikin study
title Comparison of the glidescope®, flexible fibreoptic intubating bronchoscope, iPhone modified bronchoscope, and the Macintosh laryngoscope in normal and difficult airways: a manikin study
title_full Comparison of the glidescope®, flexible fibreoptic intubating bronchoscope, iPhone modified bronchoscope, and the Macintosh laryngoscope in normal and difficult airways: a manikin study
title_fullStr Comparison of the glidescope®, flexible fibreoptic intubating bronchoscope, iPhone modified bronchoscope, and the Macintosh laryngoscope in normal and difficult airways: a manikin study
title_full_unstemmed Comparison of the glidescope®, flexible fibreoptic intubating bronchoscope, iPhone modified bronchoscope, and the Macintosh laryngoscope in normal and difficult airways: a manikin study
title_short Comparison of the glidescope®, flexible fibreoptic intubating bronchoscope, iPhone modified bronchoscope, and the Macintosh laryngoscope in normal and difficult airways: a manikin study
title_sort comparison of the glidescope®, flexible fibreoptic intubating bronchoscope, iphone modified bronchoscope, and the macintosh laryngoscope in normal and difficult airways: a manikin study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3945614/
https://www.ncbi.nlm.nih.gov/pubmed/24575885
http://dx.doi.org/10.1186/1471-2253-14-10
work_keys_str_mv AT langleyadrian comparisonoftheglidescopeflexiblefibreopticintubatingbronchoscopeiphonemodifiedbronchoscopeandthemacintoshlaryngoscopeinnormalanddifficultairwaysamanikinstudy
AT marfangabriel comparisonoftheglidescopeflexiblefibreopticintubatingbronchoscopeiphonemodifiedbronchoscopeandthemacintoshlaryngoscopeinnormalanddifficultairwaysamanikinstudy