Cargando…

Comodulation Masking Release In Electric Hearing

Comodulation masking release (CMR) is an improvement in the detection threshold of a masked signal that occurs when the masker envelopes are correlated across frequency (i.e., comodulation). CMR can be observed when flanking bands (FBs) of noise co-modulated with an on-frequency band (OFB) noise mas...

Descripción completa

Detalles Bibliográficos
Autores principales: Pierzycki, Robert H., Seeber, Bernhard U.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3946139/
https://www.ncbi.nlm.nih.gov/pubmed/24414194
http://dx.doi.org/10.1007/s10162-013-0433-9
_version_ 1782306613162409984
author Pierzycki, Robert H.
Seeber, Bernhard U.
author_facet Pierzycki, Robert H.
Seeber, Bernhard U.
author_sort Pierzycki, Robert H.
collection PubMed
description Comodulation masking release (CMR) is an improvement in the detection threshold of a masked signal that occurs when the masker envelopes are correlated across frequency (i.e., comodulation). CMR can be observed when flanking bands (FBs) of noise co-modulated with an on-frequency band (OFB) noise masker are added at remote frequencies (CMR1), or when co-modulated envelopes are used instead of anti-modulated envelopes (OFB and FB envelopes out of phase, CMR2). For FBs widely separated from the OFB, this process is assumed to rely mostly on across-channel comparison of temporal envelopes. Since cochlear implants (CIs) rely predominantly on the transmission of envelope cues, we investigated if CMR can be observed in electric hearing. We stimulated the auditory nerve of eight CI users with trains of modulated electric pulses presented on an OFB electrode alone, or together with pulse trains on one or two FB electrodes. Participants had to detect signal-induced changes in the envelope of an electric pulse train masker presented on the OFB electrode. Envelopes on FB electrodes were either co-modulated or anti-modulated with the envelope of the OFB masker. We observed CMR1 in one of the eight CI users. However, significant CMR2 was observed in most CI users. Reducing amplitude-modulation rate from 20 to 8 Hz, reducing envelopes' randomness or increasing electrode separation did not generally improve CMR1, but increased the prevalence of CMR2. The present results suggest that comodulation of envelopes can aid signal detection in electric hearing.
format Online
Article
Text
id pubmed-3946139
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-39461392014-03-12 Comodulation Masking Release In Electric Hearing Pierzycki, Robert H. Seeber, Bernhard U. J Assoc Res Otolaryngol Research Article Comodulation masking release (CMR) is an improvement in the detection threshold of a masked signal that occurs when the masker envelopes are correlated across frequency (i.e., comodulation). CMR can be observed when flanking bands (FBs) of noise co-modulated with an on-frequency band (OFB) noise masker are added at remote frequencies (CMR1), or when co-modulated envelopes are used instead of anti-modulated envelopes (OFB and FB envelopes out of phase, CMR2). For FBs widely separated from the OFB, this process is assumed to rely mostly on across-channel comparison of temporal envelopes. Since cochlear implants (CIs) rely predominantly on the transmission of envelope cues, we investigated if CMR can be observed in electric hearing. We stimulated the auditory nerve of eight CI users with trains of modulated electric pulses presented on an OFB electrode alone, or together with pulse trains on one or two FB electrodes. Participants had to detect signal-induced changes in the envelope of an electric pulse train masker presented on the OFB electrode. Envelopes on FB electrodes were either co-modulated or anti-modulated with the envelope of the OFB masker. We observed CMR1 in one of the eight CI users. However, significant CMR2 was observed in most CI users. Reducing amplitude-modulation rate from 20 to 8 Hz, reducing envelopes' randomness or increasing electrode separation did not generally improve CMR1, but increased the prevalence of CMR2. The present results suggest that comodulation of envelopes can aid signal detection in electric hearing. Springer US 2014-01-11 2014-04 /pmc/articles/PMC3946139/ /pubmed/24414194 http://dx.doi.org/10.1007/s10162-013-0433-9 Text en © The Author(s) 2014 https://creativecommons.org/licenses/by-nc/2.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Research Article
Pierzycki, Robert H.
Seeber, Bernhard U.
Comodulation Masking Release In Electric Hearing
title Comodulation Masking Release In Electric Hearing
title_full Comodulation Masking Release In Electric Hearing
title_fullStr Comodulation Masking Release In Electric Hearing
title_full_unstemmed Comodulation Masking Release In Electric Hearing
title_short Comodulation Masking Release In Electric Hearing
title_sort comodulation masking release in electric hearing
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3946139/
https://www.ncbi.nlm.nih.gov/pubmed/24414194
http://dx.doi.org/10.1007/s10162-013-0433-9
work_keys_str_mv AT pierzyckiroberth comodulationmaskingreleaseinelectrichearing
AT seeberbernhardu comodulationmaskingreleaseinelectrichearing