Cargando…
Comodulation Masking Release In Electric Hearing
Comodulation masking release (CMR) is an improvement in the detection threshold of a masked signal that occurs when the masker envelopes are correlated across frequency (i.e., comodulation). CMR can be observed when flanking bands (FBs) of noise co-modulated with an on-frequency band (OFB) noise mas...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3946139/ https://www.ncbi.nlm.nih.gov/pubmed/24414194 http://dx.doi.org/10.1007/s10162-013-0433-9 |
_version_ | 1782306613162409984 |
---|---|
author | Pierzycki, Robert H. Seeber, Bernhard U. |
author_facet | Pierzycki, Robert H. Seeber, Bernhard U. |
author_sort | Pierzycki, Robert H. |
collection | PubMed |
description | Comodulation masking release (CMR) is an improvement in the detection threshold of a masked signal that occurs when the masker envelopes are correlated across frequency (i.e., comodulation). CMR can be observed when flanking bands (FBs) of noise co-modulated with an on-frequency band (OFB) noise masker are added at remote frequencies (CMR1), or when co-modulated envelopes are used instead of anti-modulated envelopes (OFB and FB envelopes out of phase, CMR2). For FBs widely separated from the OFB, this process is assumed to rely mostly on across-channel comparison of temporal envelopes. Since cochlear implants (CIs) rely predominantly on the transmission of envelope cues, we investigated if CMR can be observed in electric hearing. We stimulated the auditory nerve of eight CI users with trains of modulated electric pulses presented on an OFB electrode alone, or together with pulse trains on one or two FB electrodes. Participants had to detect signal-induced changes in the envelope of an electric pulse train masker presented on the OFB electrode. Envelopes on FB electrodes were either co-modulated or anti-modulated with the envelope of the OFB masker. We observed CMR1 in one of the eight CI users. However, significant CMR2 was observed in most CI users. Reducing amplitude-modulation rate from 20 to 8 Hz, reducing envelopes' randomness or increasing electrode separation did not generally improve CMR1, but increased the prevalence of CMR2. The present results suggest that comodulation of envelopes can aid signal detection in electric hearing. |
format | Online Article Text |
id | pubmed-3946139 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-39461392014-03-12 Comodulation Masking Release In Electric Hearing Pierzycki, Robert H. Seeber, Bernhard U. J Assoc Res Otolaryngol Research Article Comodulation masking release (CMR) is an improvement in the detection threshold of a masked signal that occurs when the masker envelopes are correlated across frequency (i.e., comodulation). CMR can be observed when flanking bands (FBs) of noise co-modulated with an on-frequency band (OFB) noise masker are added at remote frequencies (CMR1), or when co-modulated envelopes are used instead of anti-modulated envelopes (OFB and FB envelopes out of phase, CMR2). For FBs widely separated from the OFB, this process is assumed to rely mostly on across-channel comparison of temporal envelopes. Since cochlear implants (CIs) rely predominantly on the transmission of envelope cues, we investigated if CMR can be observed in electric hearing. We stimulated the auditory nerve of eight CI users with trains of modulated electric pulses presented on an OFB electrode alone, or together with pulse trains on one or two FB electrodes. Participants had to detect signal-induced changes in the envelope of an electric pulse train masker presented on the OFB electrode. Envelopes on FB electrodes were either co-modulated or anti-modulated with the envelope of the OFB masker. We observed CMR1 in one of the eight CI users. However, significant CMR2 was observed in most CI users. Reducing amplitude-modulation rate from 20 to 8 Hz, reducing envelopes' randomness or increasing electrode separation did not generally improve CMR1, but increased the prevalence of CMR2. The present results suggest that comodulation of envelopes can aid signal detection in electric hearing. Springer US 2014-01-11 2014-04 /pmc/articles/PMC3946139/ /pubmed/24414194 http://dx.doi.org/10.1007/s10162-013-0433-9 Text en © The Author(s) 2014 https://creativecommons.org/licenses/by-nc/2.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Research Article Pierzycki, Robert H. Seeber, Bernhard U. Comodulation Masking Release In Electric Hearing |
title | Comodulation Masking Release In Electric Hearing |
title_full | Comodulation Masking Release In Electric Hearing |
title_fullStr | Comodulation Masking Release In Electric Hearing |
title_full_unstemmed | Comodulation Masking Release In Electric Hearing |
title_short | Comodulation Masking Release In Electric Hearing |
title_sort | comodulation masking release in electric hearing |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3946139/ https://www.ncbi.nlm.nih.gov/pubmed/24414194 http://dx.doi.org/10.1007/s10162-013-0433-9 |
work_keys_str_mv | AT pierzyckiroberth comodulationmaskingreleaseinelectrichearing AT seeberbernhardu comodulationmaskingreleaseinelectrichearing |