Paravalvular leak closure with two large size devices

Paravalvular leaks (PVL) after valve replacement surgeries are not uncommon. A significant number of these patients need some form of intervention as they commonly present with heart failure or severe hemolysis. Surgical correction is associated with high mortality and morbidity. Device closure of P...

Descripción completa

Detalles Bibliográficos
Autores principales: Trehan, V.K., Subhendu, M.S.K., Chaturvedi, V., Pandit, B.N., Goyal, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3946467/
https://www.ncbi.nlm.nih.gov/pubmed/24581103
http://dx.doi.org/10.1016/j.ihj.2013.12.033
_version_ 1782306652709453824
author Trehan, V.K.
Subhendu, M.S.K.
Chaturvedi, V.
Pandit, B.N.
Goyal, M.
author_facet Trehan, V.K.
Subhendu, M.S.K.
Chaturvedi, V.
Pandit, B.N.
Goyal, M.
author_sort Trehan, V.K.
collection PubMed
description Paravalvular leaks (PVL) after valve replacement surgeries are not uncommon. A significant number of these patients need some form of intervention as they commonly present with heart failure or severe hemolysis. Surgical correction is associated with high mortality and morbidity. Device closure of PVLs has been found to have good results. Since there are no devices designed specifically for PVL closure, large PVL closure is difficult. Occasional larger PVLs have been closed with a combination of a device and smaller coils. We present here a case of very large sized mitral PVL, in a patient with high risk for surgery, which was closed with two large size devices.
format Online
Article
Text
id pubmed-3946467
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-39464672014-03-25 Paravalvular leak closure with two large size devices Trehan, V.K. Subhendu, M.S.K. Chaturvedi, V. Pandit, B.N. Goyal, M. Indian Heart J Case Report Paravalvular leaks (PVL) after valve replacement surgeries are not uncommon. A significant number of these patients need some form of intervention as they commonly present with heart failure or severe hemolysis. Surgical correction is associated with high mortality and morbidity. Device closure of PVLs has been found to have good results. Since there are no devices designed specifically for PVL closure, large PVL closure is difficult. Occasional larger PVLs have been closed with a combination of a device and smaller coils. We present here a case of very large sized mitral PVL, in a patient with high risk for surgery, which was closed with two large size devices. Elsevier 2014 2013-12-26 /pmc/articles/PMC3946467/ /pubmed/24581103 http://dx.doi.org/10.1016/j.ihj.2013.12.033 Text en © 2014, Cardiological Society of India. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Trehan, V.K.
Subhendu, M.S.K.
Chaturvedi, V.
Pandit, B.N.
Goyal, M.
Paravalvular leak closure with two large size devices
title Paravalvular leak closure with two large size devices
title_full Paravalvular leak closure with two large size devices
title_fullStr Paravalvular leak closure with two large size devices
title_full_unstemmed Paravalvular leak closure with two large size devices
title_short Paravalvular leak closure with two large size devices
title_sort paravalvular leak closure with two large size devices
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3946467/
https://www.ncbi.nlm.nih.gov/pubmed/24581103
http://dx.doi.org/10.1016/j.ihj.2013.12.033
work_keys_str_mv AT trehanvk paravalvularleakclosurewithtwolargesizedevices
AT subhendumsk paravalvularleakclosurewithtwolargesizedevices
AT chaturvediv paravalvularleakclosurewithtwolargesizedevices
AT panditbn paravalvularleakclosurewithtwolargesizedevices
AT goyalm paravalvularleakclosurewithtwolargesizedevices