Cargando…
Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR)
PURPOSE: To compare a novel combined acquisition technique (CAT) of turbo-spin-echo (TSE) and echo-planar-imaging (EPI) with conventional TSE. CAT reduces the electromagnetic energy load transmitted for spin excitation. This radiofrequency (RF) burden is limited by the specific absorption rate (SAR)...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3946656/ https://www.ncbi.nlm.nih.gov/pubmed/24608106 http://dx.doi.org/10.1371/journal.pone.0091030 |
_version_ | 1782306675601965056 |
---|---|
author | Biller, Armin Choli, Morwan Blaimer, Martin Breuer, Felix A. Jakob, Peter M. Bartsch, Andreas J. |
author_facet | Biller, Armin Choli, Morwan Blaimer, Martin Breuer, Felix A. Jakob, Peter M. Bartsch, Andreas J. |
author_sort | Biller, Armin |
collection | PubMed |
description | PURPOSE: To compare a novel combined acquisition technique (CAT) of turbo-spin-echo (TSE) and echo-planar-imaging (EPI) with conventional TSE. CAT reduces the electromagnetic energy load transmitted for spin excitation. This radiofrequency (RF) burden is limited by the specific absorption rate (SAR) for patient safety. SAR limits restrict high-field MRI applications, in particular. MATERIAL AND METHODS: The study was approved by the local Medical Ethics Committee. Written informed consent was obtained from all participants. T2- and PD-weighted brain images of n = 40 Multiple Sclerosis (MS) patients were acquired by CAT and TSE at 3 Tesla. Lesions were recorded by two blinded, board-certificated neuroradiologists. Diagnostic equivalence of CAT and TSE to detect MS lesions was evaluated along with their SAR, sound pressure level (SPL) and sensations of acoustic noise, heating, vibration and peripheral nerve stimulation. RESULTS: Every MS lesion revealed on TSE was detected by CAT according to both raters (Cohen’s kappa of within-rater/across-CAT/TSE lesion detection κ(CAT) = 1.00, at an inter-rater lesion detection agreement of κ(LES) = 0.82). CAT reduced the SAR burden significantly compared to TSE (p<0.001). Mean SAR differences between TSE and CAT were 29.0 (±5.7) % for the T2-contrast and 32.7 (±21.9) % for the PD-contrast (expressed as percentages of the effective SAR limit of 3.2 W/kg for head examinations). Average SPL of CAT was no louder than during TSE. Sensations of CAT- vs. TSE-induced heating, noise and scanning vibrations did not differ. CONCLUSION: T2−/PD-CAT is diagnostically equivalent to TSE for MS lesion detection yet substantially reduces the RF exposure. Such SAR reduction facilitates high-field MRI applications at 3 Tesla or above and corresponding protocol standardizations but CAT can also be used to scan faster, at higher resolution or with more slices. According to our data, CAT is no more uncomfortable than TSE scanning. |
format | Online Article Text |
id | pubmed-3946656 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-39466562014-03-10 Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR) Biller, Armin Choli, Morwan Blaimer, Martin Breuer, Felix A. Jakob, Peter M. Bartsch, Andreas J. PLoS One Research Article PURPOSE: To compare a novel combined acquisition technique (CAT) of turbo-spin-echo (TSE) and echo-planar-imaging (EPI) with conventional TSE. CAT reduces the electromagnetic energy load transmitted for spin excitation. This radiofrequency (RF) burden is limited by the specific absorption rate (SAR) for patient safety. SAR limits restrict high-field MRI applications, in particular. MATERIAL AND METHODS: The study was approved by the local Medical Ethics Committee. Written informed consent was obtained from all participants. T2- and PD-weighted brain images of n = 40 Multiple Sclerosis (MS) patients were acquired by CAT and TSE at 3 Tesla. Lesions were recorded by two blinded, board-certificated neuroradiologists. Diagnostic equivalence of CAT and TSE to detect MS lesions was evaluated along with their SAR, sound pressure level (SPL) and sensations of acoustic noise, heating, vibration and peripheral nerve stimulation. RESULTS: Every MS lesion revealed on TSE was detected by CAT according to both raters (Cohen’s kappa of within-rater/across-CAT/TSE lesion detection κ(CAT) = 1.00, at an inter-rater lesion detection agreement of κ(LES) = 0.82). CAT reduced the SAR burden significantly compared to TSE (p<0.001). Mean SAR differences between TSE and CAT were 29.0 (±5.7) % for the T2-contrast and 32.7 (±21.9) % for the PD-contrast (expressed as percentages of the effective SAR limit of 3.2 W/kg for head examinations). Average SPL of CAT was no louder than during TSE. Sensations of CAT- vs. TSE-induced heating, noise and scanning vibrations did not differ. CONCLUSION: T2−/PD-CAT is diagnostically equivalent to TSE for MS lesion detection yet substantially reduces the RF exposure. Such SAR reduction facilitates high-field MRI applications at 3 Tesla or above and corresponding protocol standardizations but CAT can also be used to scan faster, at higher resolution or with more slices. According to our data, CAT is no more uncomfortable than TSE scanning. Public Library of Science 2014-03-07 /pmc/articles/PMC3946656/ /pubmed/24608106 http://dx.doi.org/10.1371/journal.pone.0091030 Text en © 2014 Biller et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Biller, Armin Choli, Morwan Blaimer, Martin Breuer, Felix A. Jakob, Peter M. Bartsch, Andreas J. Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR) |
title | Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR) |
title_full | Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR) |
title_fullStr | Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR) |
title_full_unstemmed | Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR) |
title_short | Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR) |
title_sort | combined acquisition technique (cat) for neuroimaging of multiple sclerosis at low specific absorption rates (sar) |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3946656/ https://www.ncbi.nlm.nih.gov/pubmed/24608106 http://dx.doi.org/10.1371/journal.pone.0091030 |
work_keys_str_mv | AT billerarmin combinedacquisitiontechniquecatforneuroimagingofmultiplesclerosisatlowspecificabsorptionratessar AT cholimorwan combinedacquisitiontechniquecatforneuroimagingofmultiplesclerosisatlowspecificabsorptionratessar AT blaimermartin combinedacquisitiontechniquecatforneuroimagingofmultiplesclerosisatlowspecificabsorptionratessar AT breuerfelixa combinedacquisitiontechniquecatforneuroimagingofmultiplesclerosisatlowspecificabsorptionratessar AT jakobpeterm combinedacquisitiontechniquecatforneuroimagingofmultiplesclerosisatlowspecificabsorptionratessar AT bartschandreasj combinedacquisitiontechniquecatforneuroimagingofmultiplesclerosisatlowspecificabsorptionratessar |