Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR)

PURPOSE: To compare a novel combined acquisition technique (CAT) of turbo-spin-echo (TSE) and echo-planar-imaging (EPI) with conventional TSE. CAT reduces the electromagnetic energy load transmitted for spin excitation. This radiofrequency (RF) burden is limited by the specific absorption rate (SAR)...

Descripción completa

Detalles Bibliográficos
Autores principales: Biller, Armin, Choli, Morwan, Blaimer, Martin, Breuer, Felix A., Jakob, Peter M., Bartsch, Andreas J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3946656/
https://www.ncbi.nlm.nih.gov/pubmed/24608106
http://dx.doi.org/10.1371/journal.pone.0091030
_version_ 1782306675601965056
author Biller, Armin
Choli, Morwan
Blaimer, Martin
Breuer, Felix A.
Jakob, Peter M.
Bartsch, Andreas J.
author_facet Biller, Armin
Choli, Morwan
Blaimer, Martin
Breuer, Felix A.
Jakob, Peter M.
Bartsch, Andreas J.
author_sort Biller, Armin
collection PubMed
description PURPOSE: To compare a novel combined acquisition technique (CAT) of turbo-spin-echo (TSE) and echo-planar-imaging (EPI) with conventional TSE. CAT reduces the electromagnetic energy load transmitted for spin excitation. This radiofrequency (RF) burden is limited by the specific absorption rate (SAR) for patient safety. SAR limits restrict high-field MRI applications, in particular. MATERIAL AND METHODS: The study was approved by the local Medical Ethics Committee. Written informed consent was obtained from all participants. T2- and PD-weighted brain images of n = 40 Multiple Sclerosis (MS) patients were acquired by CAT and TSE at 3 Tesla. Lesions were recorded by two blinded, board-certificated neuroradiologists. Diagnostic equivalence of CAT and TSE to detect MS lesions was evaluated along with their SAR, sound pressure level (SPL) and sensations of acoustic noise, heating, vibration and peripheral nerve stimulation. RESULTS: Every MS lesion revealed on TSE was detected by CAT according to both raters (Cohen’s kappa of within-rater/across-CAT/TSE lesion detection κ(CAT) = 1.00, at an inter-rater lesion detection agreement of κ(LES) = 0.82). CAT reduced the SAR burden significantly compared to TSE (p<0.001). Mean SAR differences between TSE and CAT were 29.0 (±5.7) % for the T2-contrast and 32.7 (±21.9) % for the PD-contrast (expressed as percentages of the effective SAR limit of 3.2 W/kg for head examinations). Average SPL of CAT was no louder than during TSE. Sensations of CAT- vs. TSE-induced heating, noise and scanning vibrations did not differ. CONCLUSION: T2−/PD-CAT is diagnostically equivalent to TSE for MS lesion detection yet substantially reduces the RF exposure. Such SAR reduction facilitates high-field MRI applications at 3 Tesla or above and corresponding protocol standardizations but CAT can also be used to scan faster, at higher resolution or with more slices. According to our data, CAT is no more uncomfortable than TSE scanning.
format Online
Article
Text
id pubmed-3946656
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-39466562014-03-10 Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR) Biller, Armin Choli, Morwan Blaimer, Martin Breuer, Felix A. Jakob, Peter M. Bartsch, Andreas J. PLoS One Research Article PURPOSE: To compare a novel combined acquisition technique (CAT) of turbo-spin-echo (TSE) and echo-planar-imaging (EPI) with conventional TSE. CAT reduces the electromagnetic energy load transmitted for spin excitation. This radiofrequency (RF) burden is limited by the specific absorption rate (SAR) for patient safety. SAR limits restrict high-field MRI applications, in particular. MATERIAL AND METHODS: The study was approved by the local Medical Ethics Committee. Written informed consent was obtained from all participants. T2- and PD-weighted brain images of n = 40 Multiple Sclerosis (MS) patients were acquired by CAT and TSE at 3 Tesla. Lesions were recorded by two blinded, board-certificated neuroradiologists. Diagnostic equivalence of CAT and TSE to detect MS lesions was evaluated along with their SAR, sound pressure level (SPL) and sensations of acoustic noise, heating, vibration and peripheral nerve stimulation. RESULTS: Every MS lesion revealed on TSE was detected by CAT according to both raters (Cohen’s kappa of within-rater/across-CAT/TSE lesion detection κ(CAT) = 1.00, at an inter-rater lesion detection agreement of κ(LES) = 0.82). CAT reduced the SAR burden significantly compared to TSE (p<0.001). Mean SAR differences between TSE and CAT were 29.0 (±5.7) % for the T2-contrast and 32.7 (±21.9) % for the PD-contrast (expressed as percentages of the effective SAR limit of 3.2 W/kg for head examinations). Average SPL of CAT was no louder than during TSE. Sensations of CAT- vs. TSE-induced heating, noise and scanning vibrations did not differ. CONCLUSION: T2−/PD-CAT is diagnostically equivalent to TSE for MS lesion detection yet substantially reduces the RF exposure. Such SAR reduction facilitates high-field MRI applications at 3 Tesla or above and corresponding protocol standardizations but CAT can also be used to scan faster, at higher resolution or with more slices. According to our data, CAT is no more uncomfortable than TSE scanning. Public Library of Science 2014-03-07 /pmc/articles/PMC3946656/ /pubmed/24608106 http://dx.doi.org/10.1371/journal.pone.0091030 Text en © 2014 Biller et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Biller, Armin
Choli, Morwan
Blaimer, Martin
Breuer, Felix A.
Jakob, Peter M.
Bartsch, Andreas J.
Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR)
title Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR)
title_full Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR)
title_fullStr Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR)
title_full_unstemmed Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR)
title_short Combined Acquisition Technique (CAT) for Neuroimaging of Multiple Sclerosis at Low Specific Absorption Rates (SAR)
title_sort combined acquisition technique (cat) for neuroimaging of multiple sclerosis at low specific absorption rates (sar)
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3946656/
https://www.ncbi.nlm.nih.gov/pubmed/24608106
http://dx.doi.org/10.1371/journal.pone.0091030
work_keys_str_mv AT billerarmin combinedacquisitiontechniquecatforneuroimagingofmultiplesclerosisatlowspecificabsorptionratessar
AT cholimorwan combinedacquisitiontechniquecatforneuroimagingofmultiplesclerosisatlowspecificabsorptionratessar
AT blaimermartin combinedacquisitiontechniquecatforneuroimagingofmultiplesclerosisatlowspecificabsorptionratessar
AT breuerfelixa combinedacquisitiontechniquecatforneuroimagingofmultiplesclerosisatlowspecificabsorptionratessar
AT jakobpeterm combinedacquisitiontechniquecatforneuroimagingofmultiplesclerosisatlowspecificabsorptionratessar
AT bartschandreasj combinedacquisitiontechniquecatforneuroimagingofmultiplesclerosisatlowspecificabsorptionratessar