Non-Contrast-Enhanced MR Angiography at 3 Tesla in Patients with Advanced Peripheral Arterial Occlusive Disease
PURPOSE: The aim of this study was to assess the diagnostic performance of ECG-gated non-contrast-enhanced quiescent interval single-shot (QISS) magnetic resonance angiography at a magnetic field strength of 3 Tesla in patients with advanced peripheral arterial occlusive disease (PAOD). METHOD AND M...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3946661/ https://www.ncbi.nlm.nih.gov/pubmed/24608937 http://dx.doi.org/10.1371/journal.pone.0091078 |
_version_ | 1782306676536246272 |
---|---|
author | Thierfelder, Kolja M. Meimarakis, Georgios Nikolaou, Konstantin Sommer, Wieland H. Schmitt, Peter Kazmierczak, Philipp M. Reiser, Maximilian F. Theisen, Daniel |
author_facet | Thierfelder, Kolja M. Meimarakis, Georgios Nikolaou, Konstantin Sommer, Wieland H. Schmitt, Peter Kazmierczak, Philipp M. Reiser, Maximilian F. Theisen, Daniel |
author_sort | Thierfelder, Kolja M. |
collection | PubMed |
description | PURPOSE: The aim of this study was to assess the diagnostic performance of ECG-gated non-contrast-enhanced quiescent interval single-shot (QISS) magnetic resonance angiography at a magnetic field strength of 3 Tesla in patients with advanced peripheral arterial occlusive disease (PAOD). METHOD AND MATERIALS: A total of 21 consecutive patients with advanced PAOD (Fontaine stage IIb and higher) referred for peripheral magnetic resonance angiography (MRA) were included. Imaging was performed on a 3 T whole body MR. Image quality and stenosis diameter were evaluated in comparison to contrast-enhanced continuous table and TWIST MRA (CE-MRA) as standard of reference. QISS images were acquired with a thickness of 1.5 mm each (high-resolution QISS, HR-QISS). Two blinded readers rated the image quality and the degree of stenosis for both HR-QISS and CE-MRA in 26 predefined arterial vessel segments on 5-point Likert scales. RESULTS: With CE-MRA as the reference standard, HR-QISS showed high sensitivity (94.1%), specificity (97.8%), positive (95.1%), and negative predictive value (97.2%) for the detection of significant (≥50%) stenosis. Interreader agreement for stenosis assessment of both HR-QISS and CE-MRA was excellent (κ-values of 0.951 and 0.962, respectively). As compared to CR-MRA, image quality of HR-QISS was significantly lower for the distal aorta, the femoral and iliac arteries (each with p<0.01), while no significant difference was found in the popliteal (p = 0.09) and lower leg arteries (p = 0.78). CONCLUSION: Non-enhanced ECG-gated HR-QISS performs very well in subjects with severe PAOD and is a good alternative for patients with a high risk of nephrogenic systemic fibrosis. |
format | Online Article Text |
id | pubmed-3946661 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-39466612014-03-10 Non-Contrast-Enhanced MR Angiography at 3 Tesla in Patients with Advanced Peripheral Arterial Occlusive Disease Thierfelder, Kolja M. Meimarakis, Georgios Nikolaou, Konstantin Sommer, Wieland H. Schmitt, Peter Kazmierczak, Philipp M. Reiser, Maximilian F. Theisen, Daniel PLoS One Research Article PURPOSE: The aim of this study was to assess the diagnostic performance of ECG-gated non-contrast-enhanced quiescent interval single-shot (QISS) magnetic resonance angiography at a magnetic field strength of 3 Tesla in patients with advanced peripheral arterial occlusive disease (PAOD). METHOD AND MATERIALS: A total of 21 consecutive patients with advanced PAOD (Fontaine stage IIb and higher) referred for peripheral magnetic resonance angiography (MRA) were included. Imaging was performed on a 3 T whole body MR. Image quality and stenosis diameter were evaluated in comparison to contrast-enhanced continuous table and TWIST MRA (CE-MRA) as standard of reference. QISS images were acquired with a thickness of 1.5 mm each (high-resolution QISS, HR-QISS). Two blinded readers rated the image quality and the degree of stenosis for both HR-QISS and CE-MRA in 26 predefined arterial vessel segments on 5-point Likert scales. RESULTS: With CE-MRA as the reference standard, HR-QISS showed high sensitivity (94.1%), specificity (97.8%), positive (95.1%), and negative predictive value (97.2%) for the detection of significant (≥50%) stenosis. Interreader agreement for stenosis assessment of both HR-QISS and CE-MRA was excellent (κ-values of 0.951 and 0.962, respectively). As compared to CR-MRA, image quality of HR-QISS was significantly lower for the distal aorta, the femoral and iliac arteries (each with p<0.01), while no significant difference was found in the popliteal (p = 0.09) and lower leg arteries (p = 0.78). CONCLUSION: Non-enhanced ECG-gated HR-QISS performs very well in subjects with severe PAOD and is a good alternative for patients with a high risk of nephrogenic systemic fibrosis. Public Library of Science 2014-03-07 /pmc/articles/PMC3946661/ /pubmed/24608937 http://dx.doi.org/10.1371/journal.pone.0091078 Text en © 2014 Thierfelder et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Thierfelder, Kolja M. Meimarakis, Georgios Nikolaou, Konstantin Sommer, Wieland H. Schmitt, Peter Kazmierczak, Philipp M. Reiser, Maximilian F. Theisen, Daniel Non-Contrast-Enhanced MR Angiography at 3 Tesla in Patients with Advanced Peripheral Arterial Occlusive Disease |
title | Non-Contrast-Enhanced MR Angiography at 3 Tesla in Patients with Advanced Peripheral Arterial Occlusive Disease |
title_full | Non-Contrast-Enhanced MR Angiography at 3 Tesla in Patients with Advanced Peripheral Arterial Occlusive Disease |
title_fullStr | Non-Contrast-Enhanced MR Angiography at 3 Tesla in Patients with Advanced Peripheral Arterial Occlusive Disease |
title_full_unstemmed | Non-Contrast-Enhanced MR Angiography at 3 Tesla in Patients with Advanced Peripheral Arterial Occlusive Disease |
title_short | Non-Contrast-Enhanced MR Angiography at 3 Tesla in Patients with Advanced Peripheral Arterial Occlusive Disease |
title_sort | non-contrast-enhanced mr angiography at 3 tesla in patients with advanced peripheral arterial occlusive disease |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3946661/ https://www.ncbi.nlm.nih.gov/pubmed/24608937 http://dx.doi.org/10.1371/journal.pone.0091078 |
work_keys_str_mv | AT thierfelderkoljam noncontrastenhancedmrangiographyat3teslainpatientswithadvancedperipheralarterialocclusivedisease AT meimarakisgeorgios noncontrastenhancedmrangiographyat3teslainpatientswithadvancedperipheralarterialocclusivedisease AT nikolaoukonstantin noncontrastenhancedmrangiographyat3teslainpatientswithadvancedperipheralarterialocclusivedisease AT sommerwielandh noncontrastenhancedmrangiographyat3teslainpatientswithadvancedperipheralarterialocclusivedisease AT schmittpeter noncontrastenhancedmrangiographyat3teslainpatientswithadvancedperipheralarterialocclusivedisease AT kazmierczakphilippm noncontrastenhancedmrangiographyat3teslainpatientswithadvancedperipheralarterialocclusivedisease AT reisermaximilianf noncontrastenhancedmrangiographyat3teslainpatientswithadvancedperipheralarterialocclusivedisease AT theisendaniel noncontrastenhancedmrangiographyat3teslainpatientswithadvancedperipheralarterialocclusivedisease |