Cargando…
Binary Effect of Fly Ash and Palm Oil Fuel Ash on Heat of Hydration Aerated Concrete
The binary effect of pulverized fuel ash (PFA) and palm oil fuel ash (POFA) on heat of hydration of aerated concrete was studied. Three aerated concrete mixes were prepared, namely, concrete containing 100% ordinary Portland cement (control sample or Type I), binary concrete made from 50% POFA (Type...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3947702/ https://www.ncbi.nlm.nih.gov/pubmed/24696646 http://dx.doi.org/10.1155/2014/461241 |
_version_ | 1782306708407713792 |
---|---|
author | Mehmannavaz, Taha Ismail, Mohammad Radin Sumadi, Salihuddin Rafique Bhutta, Muhammad Aamer Samadi, Mostafa Sajjadi, Seyed Mahdi |
author_facet | Mehmannavaz, Taha Ismail, Mohammad Radin Sumadi, Salihuddin Rafique Bhutta, Muhammad Aamer Samadi, Mostafa Sajjadi, Seyed Mahdi |
author_sort | Mehmannavaz, Taha |
collection | PubMed |
description | The binary effect of pulverized fuel ash (PFA) and palm oil fuel ash (POFA) on heat of hydration of aerated concrete was studied. Three aerated concrete mixes were prepared, namely, concrete containing 100% ordinary Portland cement (control sample or Type I), binary concrete made from 50% POFA (Type II), and ternary concrete containing 30% POFA and 20% PFA (Type III). It is found that the temperature increases due to heat of hydration through all the concrete specimens especially in the control sample. However, the total temperature rises caused by the heat of hydration through both of the new binary and ternary concrete were significantly lower than the control sample. The obtained results reveal that the replacement of Portland cement with binary and ternary materials is beneficial, particularly for mass concrete where thermal cracking due to extreme heat rise is of great concern. |
format | Online Article Text |
id | pubmed-3947702 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-39477022014-04-02 Binary Effect of Fly Ash and Palm Oil Fuel Ash on Heat of Hydration Aerated Concrete Mehmannavaz, Taha Ismail, Mohammad Radin Sumadi, Salihuddin Rafique Bhutta, Muhammad Aamer Samadi, Mostafa Sajjadi, Seyed Mahdi ScientificWorldJournal Research Article The binary effect of pulverized fuel ash (PFA) and palm oil fuel ash (POFA) on heat of hydration of aerated concrete was studied. Three aerated concrete mixes were prepared, namely, concrete containing 100% ordinary Portland cement (control sample or Type I), binary concrete made from 50% POFA (Type II), and ternary concrete containing 30% POFA and 20% PFA (Type III). It is found that the temperature increases due to heat of hydration through all the concrete specimens especially in the control sample. However, the total temperature rises caused by the heat of hydration through both of the new binary and ternary concrete were significantly lower than the control sample. The obtained results reveal that the replacement of Portland cement with binary and ternary materials is beneficial, particularly for mass concrete where thermal cracking due to extreme heat rise is of great concern. Hindawi Publishing Corporation 2014-02-13 /pmc/articles/PMC3947702/ /pubmed/24696646 http://dx.doi.org/10.1155/2014/461241 Text en Copyright © 2014 Taha Mehmannavaz et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Mehmannavaz, Taha Ismail, Mohammad Radin Sumadi, Salihuddin Rafique Bhutta, Muhammad Aamer Samadi, Mostafa Sajjadi, Seyed Mahdi Binary Effect of Fly Ash and Palm Oil Fuel Ash on Heat of Hydration Aerated Concrete |
title | Binary Effect of Fly Ash and Palm Oil Fuel Ash on Heat of Hydration Aerated Concrete |
title_full | Binary Effect of Fly Ash and Palm Oil Fuel Ash on Heat of Hydration Aerated Concrete |
title_fullStr | Binary Effect of Fly Ash and Palm Oil Fuel Ash on Heat of Hydration Aerated Concrete |
title_full_unstemmed | Binary Effect of Fly Ash and Palm Oil Fuel Ash on Heat of Hydration Aerated Concrete |
title_short | Binary Effect of Fly Ash and Palm Oil Fuel Ash on Heat of Hydration Aerated Concrete |
title_sort | binary effect of fly ash and palm oil fuel ash on heat of hydration aerated concrete |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3947702/ https://www.ncbi.nlm.nih.gov/pubmed/24696646 http://dx.doi.org/10.1155/2014/461241 |
work_keys_str_mv | AT mehmannavaztaha binaryeffectofflyashandpalmoilfuelashonheatofhydrationaeratedconcrete AT ismailmohammad binaryeffectofflyashandpalmoilfuelashonheatofhydrationaeratedconcrete AT radinsumadisalihuddin binaryeffectofflyashandpalmoilfuelashonheatofhydrationaeratedconcrete AT rafiquebhuttamuhammadaamer binaryeffectofflyashandpalmoilfuelashonheatofhydrationaeratedconcrete AT samadimostafa binaryeffectofflyashandpalmoilfuelashonheatofhydrationaeratedconcrete AT sajjadiseyedmahdi binaryeffectofflyashandpalmoilfuelashonheatofhydrationaeratedconcrete |