Cargando…

Comparison of Real-Time Water Proton Spectroscopy and Echo-Planar Imaging Sensitivity to the BOLD Effect at 3 T and at 7 T

Gradient-echo echo-planar imaging (GE EPI) is the most commonly used approach to assess localized blood oxygen level dependent (BOLD) signal changes in real-time. Alternatively, real-time spin-echo single-voxel spectroscopy (SE SVS) has recently been introduced for spatially specific BOLD neurofeedb...

Descripción completa

Detalles Bibliográficos
Autores principales: Koush, Yury, Elliott, Mark A., Scharnowski, Frank, Mathiak, Klaus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3948886/
https://www.ncbi.nlm.nih.gov/pubmed/24614912
http://dx.doi.org/10.1371/journal.pone.0091620
_version_ 1782306849119272960
author Koush, Yury
Elliott, Mark A.
Scharnowski, Frank
Mathiak, Klaus
author_facet Koush, Yury
Elliott, Mark A.
Scharnowski, Frank
Mathiak, Klaus
author_sort Koush, Yury
collection PubMed
description Gradient-echo echo-planar imaging (GE EPI) is the most commonly used approach to assess localized blood oxygen level dependent (BOLD) signal changes in real-time. Alternatively, real-time spin-echo single-voxel spectroscopy (SE SVS) has recently been introduced for spatially specific BOLD neurofeedback at 3 T and at 7 T. However, currently it is not known how neurofeedback based on real-time SE SVS compares to real-time GE EPI-based. We therefore compared both methods at high (3 T) and at ultra-high (7 T) magnetic field strengths. We evaluated standard quality measures of both methods for signals originating from the motor cortex, the visual cortex, and for a neurofeedback condition. At 3 T, the data quality of the real-time SE SVS and GE EPI R2* estimates were comparable. At 7 T, the data quality of the real-time GE EPI acquisitions was superior compared to those of the real-time SE SVS. Despite the somehow lower data quality of real-time SE SVS compared to GE EPI at 7 T, SE SVS acquisitions might still be an interesting alternative. Real-time SE SVS allows for a direct and subject-specific T2* estimation and thus for a physiologically more plausible neurofeedback signal.
format Online
Article
Text
id pubmed-3948886
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-39488862014-03-13 Comparison of Real-Time Water Proton Spectroscopy and Echo-Planar Imaging Sensitivity to the BOLD Effect at 3 T and at 7 T Koush, Yury Elliott, Mark A. Scharnowski, Frank Mathiak, Klaus PLoS One Research Article Gradient-echo echo-planar imaging (GE EPI) is the most commonly used approach to assess localized blood oxygen level dependent (BOLD) signal changes in real-time. Alternatively, real-time spin-echo single-voxel spectroscopy (SE SVS) has recently been introduced for spatially specific BOLD neurofeedback at 3 T and at 7 T. However, currently it is not known how neurofeedback based on real-time SE SVS compares to real-time GE EPI-based. We therefore compared both methods at high (3 T) and at ultra-high (7 T) magnetic field strengths. We evaluated standard quality measures of both methods for signals originating from the motor cortex, the visual cortex, and for a neurofeedback condition. At 3 T, the data quality of the real-time SE SVS and GE EPI R2* estimates were comparable. At 7 T, the data quality of the real-time GE EPI acquisitions was superior compared to those of the real-time SE SVS. Despite the somehow lower data quality of real-time SE SVS compared to GE EPI at 7 T, SE SVS acquisitions might still be an interesting alternative. Real-time SE SVS allows for a direct and subject-specific T2* estimation and thus for a physiologically more plausible neurofeedback signal. Public Library of Science 2014-03-10 /pmc/articles/PMC3948886/ /pubmed/24614912 http://dx.doi.org/10.1371/journal.pone.0091620 Text en © 2014 Koush et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Koush, Yury
Elliott, Mark A.
Scharnowski, Frank
Mathiak, Klaus
Comparison of Real-Time Water Proton Spectroscopy and Echo-Planar Imaging Sensitivity to the BOLD Effect at 3 T and at 7 T
title Comparison of Real-Time Water Proton Spectroscopy and Echo-Planar Imaging Sensitivity to the BOLD Effect at 3 T and at 7 T
title_full Comparison of Real-Time Water Proton Spectroscopy and Echo-Planar Imaging Sensitivity to the BOLD Effect at 3 T and at 7 T
title_fullStr Comparison of Real-Time Water Proton Spectroscopy and Echo-Planar Imaging Sensitivity to the BOLD Effect at 3 T and at 7 T
title_full_unstemmed Comparison of Real-Time Water Proton Spectroscopy and Echo-Planar Imaging Sensitivity to the BOLD Effect at 3 T and at 7 T
title_short Comparison of Real-Time Water Proton Spectroscopy and Echo-Planar Imaging Sensitivity to the BOLD Effect at 3 T and at 7 T
title_sort comparison of real-time water proton spectroscopy and echo-planar imaging sensitivity to the bold effect at 3 t and at 7 t
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3948886/
https://www.ncbi.nlm.nih.gov/pubmed/24614912
http://dx.doi.org/10.1371/journal.pone.0091620
work_keys_str_mv AT koushyury comparisonofrealtimewaterprotonspectroscopyandechoplanarimagingsensitivitytotheboldeffectat3tandat7t
AT elliottmarka comparisonofrealtimewaterprotonspectroscopyandechoplanarimagingsensitivitytotheboldeffectat3tandat7t
AT scharnowskifrank comparisonofrealtimewaterprotonspectroscopyandechoplanarimagingsensitivitytotheboldeffectat3tandat7t
AT mathiakklaus comparisonofrealtimewaterprotonspectroscopyandechoplanarimagingsensitivitytotheboldeffectat3tandat7t