Cargando…

A new device to test cutting efficiency of mechanical endodontic instruments

BACKGROUND: The purpose of the present study was to introduce a new device specifically designed to evaluate the cutting efficiency of mechanically driven endodontic instruments. MATERIAL/METHODS: Twenty new Reciproc R25 (VDW, Munich, Germany) files were used to be investigated in the new device dev...

Descripción completa

Detalles Bibliográficos
Autores principales: Rubini, Alessio Giansiracusa, Plotino, Gianluca, Al-Sudani, Dina, Grande, Nicola M., Putorti, Ermanno, Sonnino, GianPaolo, Cotti, Elisabetta, Testarelli, Luca, Gambarini, Gianluca
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2014
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3948890/
https://www.ncbi.nlm.nih.gov/pubmed/24603777
http://dx.doi.org/10.12659/MSM.890119
_version_ 1782306850029436928
author Rubini, Alessio Giansiracusa
Plotino, Gianluca
Al-Sudani, Dina
Grande, Nicola M.
Putorti, Ermanno
Sonnino, GianPaolo
Cotti, Elisabetta
Testarelli, Luca
Gambarini, Gianluca
author_facet Rubini, Alessio Giansiracusa
Plotino, Gianluca
Al-Sudani, Dina
Grande, Nicola M.
Putorti, Ermanno
Sonnino, GianPaolo
Cotti, Elisabetta
Testarelli, Luca
Gambarini, Gianluca
author_sort Rubini, Alessio Giansiracusa
collection PubMed
description BACKGROUND: The purpose of the present study was to introduce a new device specifically designed to evaluate the cutting efficiency of mechanically driven endodontic instruments. MATERIAL/METHODS: Twenty new Reciproc R25 (VDW, Munich, Germany) files were used to be investigated in the new device developed to test the cutting ability of endodontic instruments. The device consists of a main frame to which a mobile plastic support for the hand-piece is connected and a stainless-steel block containing a Plexiglas block against which the cutting efficiency of the instruments was tested. The length of the block cut in 1 minute was measured in a computerized program with a precision of 0.1mm. The instruments were activated by using a torque-controlled motor (Silver Reciproc; VDW, Munich, Germany) in a reciprocating movement by the “Reciproc ALL” program (Group 1) and in counter-clockwise rotation at 300 rpm (Group 2). Mean and standard deviations of each group were calculated and data were statistically analyzed with a one-way ANOVA test (P<0.05). RESULTS: Reciproc in reciprocation (Group 1) mean cut in the Plexiglas block was 8.6 mm (SD=0.6 mm), while Reciproc in rotation mean cut was 8.9 mm (SD=0.7 mm). There was no statistically significant difference between the 2 groups investigated (P>0.05). CONCLUSIONS: The cutting testing device evaluated in the present study was reliable and easy to use and may be effectively used to test cutting efficiency of both rotary and reciprocating mechanical endodontic instruments.
format Online
Article
Text
id pubmed-3948890
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-39488902014-03-12 A new device to test cutting efficiency of mechanical endodontic instruments Rubini, Alessio Giansiracusa Plotino, Gianluca Al-Sudani, Dina Grande, Nicola M. Putorti, Ermanno Sonnino, GianPaolo Cotti, Elisabetta Testarelli, Luca Gambarini, Gianluca Med Sci Monit BACKGROUND: The purpose of the present study was to introduce a new device specifically designed to evaluate the cutting efficiency of mechanically driven endodontic instruments. MATERIAL/METHODS: Twenty new Reciproc R25 (VDW, Munich, Germany) files were used to be investigated in the new device developed to test the cutting ability of endodontic instruments. The device consists of a main frame to which a mobile plastic support for the hand-piece is connected and a stainless-steel block containing a Plexiglas block against which the cutting efficiency of the instruments was tested. The length of the block cut in 1 minute was measured in a computerized program with a precision of 0.1mm. The instruments were activated by using a torque-controlled motor (Silver Reciproc; VDW, Munich, Germany) in a reciprocating movement by the “Reciproc ALL” program (Group 1) and in counter-clockwise rotation at 300 rpm (Group 2). Mean and standard deviations of each group were calculated and data were statistically analyzed with a one-way ANOVA test (P<0.05). RESULTS: Reciproc in reciprocation (Group 1) mean cut in the Plexiglas block was 8.6 mm (SD=0.6 mm), while Reciproc in rotation mean cut was 8.9 mm (SD=0.7 mm). There was no statistically significant difference between the 2 groups investigated (P>0.05). CONCLUSIONS: The cutting testing device evaluated in the present study was reliable and easy to use and may be effectively used to test cutting efficiency of both rotary and reciprocating mechanical endodontic instruments. International Scientific Literature, Inc. 2014-03-06 /pmc/articles/PMC3948890/ /pubmed/24603777 http://dx.doi.org/10.12659/MSM.890119 Text en © Med Sci Monit, 2014 This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License
spellingShingle Rubini, Alessio Giansiracusa
Plotino, Gianluca
Al-Sudani, Dina
Grande, Nicola M.
Putorti, Ermanno
Sonnino, GianPaolo
Cotti, Elisabetta
Testarelli, Luca
Gambarini, Gianluca
A new device to test cutting efficiency of mechanical endodontic instruments
title A new device to test cutting efficiency of mechanical endodontic instruments
title_full A new device to test cutting efficiency of mechanical endodontic instruments
title_fullStr A new device to test cutting efficiency of mechanical endodontic instruments
title_full_unstemmed A new device to test cutting efficiency of mechanical endodontic instruments
title_short A new device to test cutting efficiency of mechanical endodontic instruments
title_sort new device to test cutting efficiency of mechanical endodontic instruments
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3948890/
https://www.ncbi.nlm.nih.gov/pubmed/24603777
http://dx.doi.org/10.12659/MSM.890119
work_keys_str_mv AT rubinialessiogiansiracusa anewdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT plotinogianluca anewdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT alsudanidina anewdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT grandenicolam anewdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT putortiermanno anewdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT sonninogianpaolo anewdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT cottielisabetta anewdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT testarelliluca anewdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT gambarinigianluca anewdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT rubinialessiogiansiracusa newdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT plotinogianluca newdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT alsudanidina newdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT grandenicolam newdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT putortiermanno newdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT sonninogianpaolo newdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT cottielisabetta newdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT testarelliluca newdevicetotestcuttingefficiencyofmechanicalendodonticinstruments
AT gambarinigianluca newdevicetotestcuttingefficiencyofmechanicalendodonticinstruments